Download HI302 - Smar
Transcript
HI302 – User’s Manual HVT's Allocation Map for LD301 Index 16.1 16.2 16.3 16.4 16.5 16.6 16.7 16.8 16.9 16.10 16.11 16.12 16.13 16.14 16.15 16.16 16.17 16.18 16.19 16.20 17.1 17.2 17.3 17.4 17.5 17.6 17.8 17.9 17.10 17.11 17.12 17.13 17.14 17.15 17.16 17.17 17.18 17.19 17.20 C.8 Parameter Name HART Variable Name HART Command Mode FLOAT_ARRAY_1[1] FLOAT_ARRAY_1[2] FLOAT_ARRAY_1[3] FLOAT_ARRAY_1[4] FLOAT_ARRAY_1[5] FLOAT_ARRAY_1[6] FLOAT_ARRAY_1[7] FLOAT_ARRAY_1[8] FLOAT_ARRAY_1[9] FLOAT_ARRAY_1[10] FLOAT_ARRAY_1[11] FLOAT_ARRAY_1[12] FLOAT_ARRAY_1[13] FLOAT_ARRAY_1[14] FLOAT_ARRAY_1[15] FLOAT_ARRAY_1[16] FLOAT_ARRAY_1[17] FLOAT_ARRAY_1[18] FLOAT_ARRAY_1[19] FLOAT_ARRAY_1[20] FLOAT_ARRAY_2[1] FLOAT_ARRAY_2[2] FLOAT_ARRAY_2[3] FLOAT_ARRAY_2[4] FLOAT_ARRAY_2[5] FLOAT_ARRAY_2[6] FLOAT_ARRAY_2[8] FLOAT_ARRAY_2[9] FLOAT_ARRAY_2[10] FLOAT_ARRAY_2[11] FLOAT_ARRAY_2[12] FLOAT_ARRAY_2[13] FLOAT_ARRAY_2[14] FLOAT_ARRAY_2[15] FLOAT_ARRAY_2[16] FLOAT_ARRAY_2[17] FLOAT_ARRAY_2[18] FLOAT_ARRAY_2[19] FLOAT_ARRAY_2[20] PV_CURR_LEVEL_DAC_ZERO UPPER_SENSOR LOWER_SENSOR UPPER_TRIM_POINT LOWER_TRIM_POINT MEASURED_POINT_1 MEASURED_POINT_2 MEASURED_POINT_3 MEASURED_POINT_4 MEASURED_POINT_5 PROCESS_VARIABLE SET_POINT MANIPULATED_VARIABLE ERROR PROPORTIONAL_FACTOR(Kp) INTEGRAL_TIME(Tr) DERIVATIVE_TIME(Td) NON_LINEAR_FACTOR(Knl) DERIVATIVE_FACTOR(DG) MV_HIGH_LIMIT MV_LOW_LIMIT MV_RATE_CHANGE POWER_UP_SETPOINT POWER_UP_MANIPULATED_VARIABLE CUTOFF_POINT TRIM_TEMP USER_UNIT_UPPER USER_UNIT_LOWER TOTAL MAXIMUM_FLOW TOTAL_UNIT_CONV_FACTOR PV_CURR_LEVEL_DAC_GAIN SPECIAL_UNIT_OUT SET_POINT_VARIABLE X1 X2 X3 X4 X5 45 128 128 130 131 160, 162 160, 162 160, 162 160, 162 160, 162 140 140, 146 140, 147, 193 140, 193 142, 143 142, 144 142, 145 142 142 148, 149 148, 149 148, 149 150, 151, 194 150, 151 156, 157 155 178, 179 178, 179 185 186, 187 186, 188 46 193 193 133, 134 133, 134 133, 134 133, 134 133, 134 w r r w w w/r w/r w/r w/r w/r r w/r w/r r w/r w/r w/r r r w/r w/r w/r w/r w/r w/r w/r w/r r w/r w/r w r r w/r w/r w/r w/r w/r Description Set value of the trim primary variable current Dac Zero Upper sensor value Lower sensor value Write upper sensor trim point Write lower sensor trim point Measured characterization Trim Curve Point 1 Measured characterization Trim Curve Point 2 Measured characterization Trim Curve Point 3 Measured characterization Trim Curve Point 4 Measured characterization Trim Curve Point 5 Process variable (PV) value Setpoint (SP) value Manipulated variable (MV) value Error value Proportional Factor (Kp) value Integral Time (Tr) value Derivative Time (Td) value Non Linear Factor (Knl) value Derivative Factor (DG) value Manipulated variable high limit Manipulated variable low limit Manipulated variable rate of change Power Up setpoint Power Up manipulated variable Square root cutoff Trim temp User unit upper value User unit lower value Total value Maximum flow value Total unit conversion factor value Set value of the Trim Primary Variable Current Dac Gain Special Unit Output value Set Point Variable value Table Coord X1 Table Coord X2 Table Coord X3 Table Coord X4 Table Coord X5