Download HI302 - Smar

Transcript
HI302 – User’s Manual
HVT's Allocation Map for LD301
Index
16.1
16.2
16.3
16.4
16.5
16.6
16.7
16.8
16.9
16.10
16.11
16.12
16.13
16.14
16.15
16.16
16.17
16.18
16.19
16.20
17.1
17.2
17.3
17.4
17.5
17.6
17.8
17.9
17.10
17.11
17.12
17.13
17.14
17.15
17.16
17.17
17.18
17.19
17.20
C.8
Parameter Name
HART Variable Name
HART Command
Mode
FLOAT_ARRAY_1[1]
FLOAT_ARRAY_1[2]
FLOAT_ARRAY_1[3]
FLOAT_ARRAY_1[4]
FLOAT_ARRAY_1[5]
FLOAT_ARRAY_1[6]
FLOAT_ARRAY_1[7]
FLOAT_ARRAY_1[8]
FLOAT_ARRAY_1[9]
FLOAT_ARRAY_1[10]
FLOAT_ARRAY_1[11]
FLOAT_ARRAY_1[12]
FLOAT_ARRAY_1[13]
FLOAT_ARRAY_1[14]
FLOAT_ARRAY_1[15]
FLOAT_ARRAY_1[16]
FLOAT_ARRAY_1[17]
FLOAT_ARRAY_1[18]
FLOAT_ARRAY_1[19]
FLOAT_ARRAY_1[20]
FLOAT_ARRAY_2[1]
FLOAT_ARRAY_2[2]
FLOAT_ARRAY_2[3]
FLOAT_ARRAY_2[4]
FLOAT_ARRAY_2[5]
FLOAT_ARRAY_2[6]
FLOAT_ARRAY_2[8]
FLOAT_ARRAY_2[9]
FLOAT_ARRAY_2[10]
FLOAT_ARRAY_2[11]
FLOAT_ARRAY_2[12]
FLOAT_ARRAY_2[13]
FLOAT_ARRAY_2[14]
FLOAT_ARRAY_2[15]
FLOAT_ARRAY_2[16]
FLOAT_ARRAY_2[17]
FLOAT_ARRAY_2[18]
FLOAT_ARRAY_2[19]
FLOAT_ARRAY_2[20]
PV_CURR_LEVEL_DAC_ZERO
UPPER_SENSOR
LOWER_SENSOR
UPPER_TRIM_POINT
LOWER_TRIM_POINT
MEASURED_POINT_1
MEASURED_POINT_2
MEASURED_POINT_3
MEASURED_POINT_4
MEASURED_POINT_5
PROCESS_VARIABLE
SET_POINT
MANIPULATED_VARIABLE
ERROR
PROPORTIONAL_FACTOR(Kp)
INTEGRAL_TIME(Tr)
DERIVATIVE_TIME(Td)
NON_LINEAR_FACTOR(Knl)
DERIVATIVE_FACTOR(DG)
MV_HIGH_LIMIT
MV_LOW_LIMIT
MV_RATE_CHANGE
POWER_UP_SETPOINT
POWER_UP_MANIPULATED_VARIABLE
CUTOFF_POINT
TRIM_TEMP
USER_UNIT_UPPER
USER_UNIT_LOWER
TOTAL
MAXIMUM_FLOW
TOTAL_UNIT_CONV_FACTOR
PV_CURR_LEVEL_DAC_GAIN
SPECIAL_UNIT_OUT
SET_POINT_VARIABLE
X1
X2
X3
X4
X5
45
128
128
130
131
160, 162
160, 162
160, 162
160, 162
160, 162
140
140, 146
140, 147, 193
140, 193
142, 143
142, 144
142, 145
142
142
148, 149
148, 149
148, 149
150, 151, 194
150, 151
156, 157
155
178, 179
178, 179
185
186, 187
186, 188
46
193
193
133, 134
133, 134
133, 134
133, 134
133, 134
w
r
r
w
w
w/r
w/r
w/r
w/r
w/r
r
w/r
w/r
r
w/r
w/r
w/r
r
r
w/r
w/r
w/r
w/r
w/r
w/r
w/r
w/r
r
w/r
w/r
w
r
r
w/r
w/r
w/r
w/r
w/r
Description
Set value of the trim primary variable current Dac Zero
Upper sensor value
Lower sensor value
Write upper sensor trim point
Write lower sensor trim point
Measured characterization Trim Curve Point 1
Measured characterization Trim Curve Point 2
Measured characterization Trim Curve Point 3
Measured characterization Trim Curve Point 4
Measured characterization Trim Curve Point 5
Process variable (PV) value
Setpoint (SP) value
Manipulated variable (MV) value
Error value
Proportional Factor (Kp) value
Integral Time (Tr) value
Derivative Time (Td) value
Non Linear Factor (Knl) value
Derivative Factor (DG) value
Manipulated variable high limit
Manipulated variable low limit
Manipulated variable rate of change
Power Up setpoint
Power Up manipulated variable
Square root cutoff
Trim temp
User unit upper value
User unit lower value
Total value
Maximum flow value
Total unit conversion factor value
Set value of the Trim Primary Variable Current Dac Gain
Special Unit Output value
Set Point Variable value
Table Coord X1
Table Coord X2
Table Coord X3
Table Coord X4
Table Coord X5