Download FOCUS User Manual
Transcript
Appendix Operating Schedule 14.10 Upgrading from Forman 4 Due to the fact FOCUS has been build on Forman 4 technology a current Forman 4 installation can be upgraded to the FOCUS system by completing the following steps: Step 1 Run the Forman 4 Forecourt Manager, Forman4Manager.exe, and request the configuration from the PCC. This is located under the Utilities | Request Configuration tab. The Forman4Manager.exe can be run with the command line parameter 'C1', this will perform a silent request configuration returning 0 on success, or 1 on failure. Step 2 Install the FOCUS suite, refer the installation section. It is recommended that the FOCUS suite is installed to a different location, e.g. C:\Program Files\Postec\FOCUS. Step 3 Run the FOCUS Registry Upgrade Utility, RegistryUpgradeUtility.exe. This will upgrade the existing Forman 4 registry settings to FOCUS registry settings. The RegistryUpgradeUtility.exe can be run with the command line parameter 'S', this will perform a silent registry upgrade returning 0 on success, or 1 on failure. Step 4 Run the Forman 4 Upgrade application, Forman4Upgrade.exe. This application will populate the FOCUS database with data from the existing Forman 4 database. The Forman4Upgrade.exe can be run with the command line parameters 'A S', this will perform a silent database upgrade returning 0 on success, or 1 on failure. Step 5 Run the PCC Connection Wizard and setup the connection type. Registry settings are available for this, contact a Postec support engineer for more details. Note: Ensure the application node numbers are setup and appropriate applications are activated. Step 6 If the site requires a PCC software upgrade, the minimum version required for FOCUS is 628, it should be performed once the above steps have been successfully completed. It is most likely that the PCC software upgrade will involve a master reset. Should this be the case ensure you perform the PCC software upgrade and then afterwards run the Forecourt Configuration application and perform a Send Configuration to reconfigure the PCC. The Forecourt Configuration application can be run with the command line parameter 'C3', this will perform a silent send configuration returning 0 on success, or 1 on failure. Note: The Aux Devices and UPI's configuration are not stored in the Forman 4 database therefore the upgraded FOCUS database at this point will not contain them either, if you are not using the silent send configuration parameter 'C3' be sure to request these items up individually before doing the send. Step 7 If it has not been already done in step 6, perform a Send Configuration using the Forecourt Configuration application . The Forecourt Configuration application can be run with the command line parameter 'C3', this will perform a silent send configuration returning 0 on success, or 1 on failure. (See Note above). Step 8 Perform a final Request Configuration using the Forecourt Configuration application. The Forecourt Configuration application can be run with the command line parameter 'C1', this will perform a silent request configuration returning 0 on success, or 1 on failure. Step 9 © 2012 POSTEC Data Systems 216