Download NI-VISA Programmer Reference Manual
Transcript
Chapter 5 f Argument type: A reference to a floating point number. Flags or Modifiers s Operations Interpretation Default functionality Characters are read from the device until an entire number is read. The number read may be in either IEEE 488.2 formats <DECIMAL NUMERIC PROGRAM DATA> (NRf) or <NON-DECIMAL NUMERIC PROGRAM DATA> (#H, #Q, and #B). field width The input will be stored in a field at least this wide. Length modifier l arg is a reference to a double floating point number. Length modifier L arg is a reference to a long double number. , array size arg points to an array of floats (or double or long double, depending on the length modifier) of size array size. The elements of this array should be separated by commas. Elements will be read until either array size number of elements are consumed or they are no longer separated by commas. If the array size contains a number sign (#), two arguments are used. The first arg read is a pointer to an integer specifying the maximum number of elements that the array can hold. The second arg should be a reference to an array. Also, the actual number of elements read is stored back in the first argument. Argument type: A reference to a string. Flags or Modifiers Interpretation Default functionality All leading white space characters are ignored. Characters are read from the device into the string until a white space character is read. field width This flag gives the maximum string size. If the field width contains a number sign (#), two arguments are used. The first argument read is a pointer to an integer specifying the maximum array size. The second should be a reference to an array. In case of field width characters already read before encountering a white space, additional characters are read and discarded until a white space character is found. In case of # field width, the actual number of characters that were copied into the user array, not counting the trailing NULL character, are stored back in the integer pointed to by the first argument. © National Instruments Corporation 5-129 NI-VISA Programmer Reference Manual
Related documents
Agilent VISA User`s Guide
Programming Guide, E4428C/38C ESG Signal Generators
NI-VISA User Manual - National Instruments
Current Source/ Measure Module 52956 User`s Manual
プログラマーズ・ガイド - Agilent Technologies
Wavestar 2.6 Manual
Agilent Technologies 82357B User`s guide
Quick Immunity Sequencer - Kikusui Electronics Corp.
WT3000 Precision Power Analyzer User`s Manual - Electro
Agilent Technologies E2094S User`s guide
NRP-NI-VISA Passport Software Manual
Bustec VISA Library and Tools User Manual