Download Programmable digital panel meters
Transcript
CA 2100/2200ang - 08/99 1/03/00 11:12 Page 6 The C.A 2200-P is particularly designed for the measurement, over 32,000 counts, of process signals issued by “high level” sensors, with direct readout in engineering units. Equipped as standard with a supply for sensors (3 values), it accepts the most widely used signals, in the range ±10 V or ±20 mA, and can also be connected to a potentiometric type transducer, for the measurement of displacement, of length, etc. The display rule is directly programmable on the keyboard and can be linearised on 11 segments for sensors with non-linear output. Very useful in certain applications such as weighing, the C.A 2200-P can take an OFFSET from the keyboard, by simple acquisition of the measured value (tare). Lastly, four logical inputs allow four remote controls, chosen among 26 preprogrammed functions. The C.A 2200-C is specially designed for measuring loads (weights, forces, couples, pressures, etc.) over a range of 32,000 counts by means of low-level sensors such as strain gauge bridges. It can also be connected to the terminals of a DC intensity shunt. The display rule is directly programmable on the keyboard and can be linearised on 11 segments. To facilitate calibration for weighing applications, the C.A 2200-C can acquire an OFFSET from the keyboard by simply capturing the measurement. Lastly, four logical inputs allow four remote controls, chosen among 26 preprogrammed functions. C.A 2200-D Frequencymeter - Tachometer Meter - Timer • magnetic sensor: Vin > 120 mVeff • NAMUR sensor: Ion < 1 mADC / Ioff > 3 mADC / Rc = 1 kΩ The C.A 2200-T is designed for temperatures measurements, from J, K, T, R, S, E couples or Pt 100 Ω resistances. The measurements can be displayed in degrees Celsius or Fahrenheit, with a resolution of a degree or a tenth of degree. By programming, an offset can be introduced to correct the possible shift of the temperature sensor. The display of the MIN and MAX values and their resetting to zero can be controlled remotely by means of logical inputs. The C.A 2200-D is mainly intended for exploitation of pulsed logical signals for the following functions: meter with memory (batch counter, metering, countdown or two-way metering), timer with memory, frequencymeter and tachometer (frequency, rotation speed, linear speed, rate, time, etc.). The display of the MIN and MAX values and their resetting to zero can be controlled remotely by means of logical inputs. • TTL/24 V encoder or NPN/PNP sensor: “1” > 1.6 VDC / “0” < 1.5 VDC • dry contact: Vc = 5 V / Rc = 3,9 kΩ • voltage: 10...650VAC (Fmin 0.05 Hz / Fmax 20 kHz) 4 times/second • metter: ±99999 counts • timer: 0.00 s to 9999.9 h • frequencymeter: 0...25 000 counts • tachometer: 0...99999 counts 0.01% reading ±1 ct 50 ppm/°C ■ On both instruments, two digital filters can be used to stabilise the display of measurements as a function of the process conditions. ■ In addition to the display of the input variable, the DPM permanently record the minimum and maximum values. ■ Display of the measurement can be inhibited remotely by closing a contact and the MIN and MAX values can be displayed and cleared remotely. ■ On the C.A 2200-P and C.A 2200-C, the OFFSET can also be entered and cleared remotely. And the remote control functions can be modified as the user requires, with a total of 26 preprogrammed functions available in these instruments. ■ Again on the C.A 2200-P and C.A 2200-C, the display can be set to flash when an alarm threshold is exceeded. no ■ Programming of the instruments is done by means of the five keys on the front yes panel, or remotely, on a PC, by means of the DPMPROG software and a serial link. yes, by keyboard • hold display • display MIN, MAX and RESET • clear MIN, MAX and RESET 30 mA at 8 or 24 VDC THE • • • • OPTIONS OFFERED: 2 or 4 alarms on relays or opto-couplers analogue output BCD output RS232 or RS485 serial link 5