Terminal Torque
Specifications
Table 3 - Controller Information
Controller
Size
32/51/64
74/104/147
234
Power Terminals
Units
Line
Load
Control
Wire size 14…4 AWG
(2.5…25 mm2)
14…6 AWG
(2.5…16 mm2)
24…14 AWG
(0.2…2.5 mm2)
Torque
20…25 lb-in.
(2.3…2.8 Nm)
20…22.5 lb-in.
(2.3…2.6 Nm)
4.4…8 lb-in.
(0.5…0.9 Nm)
Wire size 14…3/0 AWG
(2.5…95 mm2)
14…1 AWG
(2.5…50 mm2)
24…14 AWG
(0.2…2.5 mm2)
Torque
100…110 lb-in.
(11.3…12.4 Nm)
4.4…8 lb-in.
(0.5…0.9 Nm)
Wire size 6…250 AWG
(16…120 mm2)
6…250 AWG
(16…120 mm2)
24…14 AWG
(0.2…2.5 mm2)
Torque
275 lb-in.
(31 Nm)
4.4…8 lb-in.
(0.5…0.9 Nm)
100…110 lb-in.
(11.3…12.4 Nm)
275 lb-in.
(31 Nm)
Table 4 - Fault Contactor Information
Controller
Size
32/51/64
74/104/147
234
12
Power Terminals
Units
Line
Load
Control
Wire size 14…6 AWG
(2.5…16 mm2)
14…6 AWG
(2.5…16 mm2)
16…12 AWG
(1…4 mm2)
Torque
13…31 lb-in.
(2.3…3.5 Nm)
13…31 lb-in.
(2.3…3.5 Nm)
8.9…13 lb-in.
(1…1.5 Nm)
Wire size 14…2 AWG
(2.5…35 mm2)
14…2 AWG
(2.5…35 mm2)
16…12 AWG
(1…4 mm2)
Torque
31…52 lb-in.
(3.5…6 Nm)
8.9…13 lb-in.
(1…1.5 Nm)
Wire size 6…300 AWG
(16…150 mm2)
6…300 AWG
(16…150 mm2)
2x 16…12 AWG
(2x 1…4 mm2)
Torque
250 lb-in.
(28 Nm)
12…20 lb-in.
(1.4…2.3 Nm)
31…52 lb-in.
(3.5…6 Nm)
250 lb-in.
(28 Nm)
Rockwell Automation Publication 150-UM009D-EN-P- February 2011