Download SMC Elevator Users Manual - Bulletin 150-E
Transcript
Chapter 1 Introduction This manual provides and overview of the installation, set-up, and typical operation of the Allen-Bradley hydraulic elevator and escalator starter. This solidstate starter solution is designed to operate 3-phase standard squirrel cage induction motors and can be connected to a 6 or 12 lead Wye-Delta or standard 3 or 9 lead motors. Through the use of LINE or INSIDE-THE-DELTA control, the solid-state solution can provide ultimate control of the motor. The advantages of a solid-state solution include the following: • Provides smooth motor starting. • Reduces current surges on weak electrical systems. • Reduces starting torque of the motor, wich helps to reduce mechanical stress on system components. • Helps meet both local and regional electrical codes when reduced voltage starting is a requirement. • Eliminates voltage and current spikes associated with traditional WyeDelta starters. • Maximizes the life of the motor with reduced electrical strain. • Reduces general system maintenance requirements for improved uptime. Component Overview The starter is made up of two components, the base controller and a fault contactor. Figure 1 - Bulletin 150-E Components Base Controller Fault Contactor Rockwell Automation Publication 150-UM009D-EN-P - February 2011 5