Parameterization and configuration 7.3.5.1 Definition of the operating- and safety-range Total capacity Safety range Operating range 0 = below the operating range 1 = below the operating range 0 = in the operating range 1 = in the operating range 0 = above the operating range 1 = above the operating range 0 = below the safety range 1 = below the safety range 0 = in the safety range 1 = in the safety range 0 = above the safety range 1 = above the safety range Origin lower upper Operating limit Final value lower upper Safety limit Operating limits / Safety limits EDS-file 8192 lower limit upper limit default 1 33554430 1 EDS-file 4096 1 16777214 1 © TR-Electronic GmbH 2002, All Rights Reserved Page 30 of 34 Printed in the Federal Republic of Germany TR - ECE - BA - GB - 0027 - 01 03/17/2010