NOTE 6. Terminal Wiring Diagrams Do not use unassigned terminals as relay terminals. ■ UP750 Single-loop Control (Model UP750-0䊐 or UP750-5䊐) Communication 1 Communication 2 (PSL1) (PSL2) RS-485 communication High performance * Wiring can only be carried out * Wiring can only be carried out for RS-485 communication for controllers with controllers with auxiliary analog input. PV input * Not configured at factory before shipment Not used in single-loop control. communication functions. 28 RSB(+) 23 SDB(+) 24 25 SDA(-) RDB(+) 29 RSA(-) 30 SG Auxiliary analog input RDA(-) 27 SG NC 1 NO 2 Power supply N 9 CAUTION Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. 10 Allowable range: 100-240 V AC (10%) (free voltage) 50/60 Hz shared Relay DO3 4 Common COM 7 Time event 1 output 1 41 31 21 11 2 42 32 22 12 Note: Connecting a 250 Ω resistor to the terminals is optional. Model: X010-250-2 (resistor with M3.5 crimp-on terminal lugs) 12 + 13 - 3 43 33 23 13 4 44 34 24 14 5 45 35 25 15 NOTE 6 46 36 26 16 7 47 37 27 17 8 48 38 28 18 Retransmission output 1* Control output Note: Select this option from the OT1 parameter. * Retransmission output 2 is available only when “relay” is selected as the type of control output. Current / voltage pulse output 14 + Retransmission output 2* 15 - Default: Unspecified retransmission type 9 49 39 29 19 16 + 10 50 40 30 20 17 - 0-20mADC, 4-20mADC Voltage pulse (12 V) 4-20 or 0-20 mA DC 14 + 15 - 14.5-18.0 V DC (21 mA DC max.) * The functions of a contact input can be varied by changing the setting of the contact input registration parameter. UP * OT1 is a setup parameter. You can change the settings of the parameter OT1 to change the control output type. See Initial Settings User’s Manual . External contact inputs Switch between the ON and OFF states of the DI1 to DI4 contact inputs to select from program pattern numbers 1 to 15. (Select a number during a RESET state.) 1 Correspondence between parameters OT1 and control output types 2 3 4 5 6 7 8 9 DI2 18 DI3 40 Transistor OT1=1 DI3 OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON ON ON DI4 OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON Time event 2 output DO5 33 Time event 3 output DO6 32 OT1=2 OT1=3 Start of program operation when DI5 changes from OFF to ON DO7 31 Current output (terminals 16 and 17 ) On-off control Relay output (terminals 1 , 2 and 3 ) Stop of program operation when DI6 changes from OFF to ON DI6 37 Start of local-mode operation when DI7 changes from OFF to ON DI7 36 Common COM 20 * The dual-loop type controller (UP750-5ⵧ) only “Current output terminal ( 46 and 47 )” can be used for retransmission output 2. 19 +5V DI2 18 +5V DI3 40 +5V DI4 DI4 39 NOTE Transistor contact DI1 10 11 12 13 14 15 DI1 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON DI2 OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON Time proportional control Voltage pulse output (terminals 16 and 17 ) Relay contact rating: 240 V AC, 1 A 30 V DC, 1 A (resistance load) Transistor contact rating: 24 V DC, 50 mA +5V Contact UP DI1 19 Time proportional control Relay output (terminals 1 , 2 and 3 ) COM 35 * Retransmission output 1 is not available if a15 V DC loop power supply is used. 0-20mADC, 4-20mADC 17 - OT1=0 (factory-set default) Common Load resistance: 600 Ω or less Default: 4-20 mA DC DO4 34 Time event 4 output * Factory-set to “PV retransmission.” 15 V DC loop power supply* 16 + * The functions of a contact output can be varied by changing the setting of the contact output registration parameter. PV event 2 output DO2 5 Instrument alarm 1 output 13 B Default: 4-20 mA DC External contact outputs PV event 1 output DO1 6 13 - Installation category (overvoltage category): II (IEC1010-1) 30 V DC, 3 A (resistance load) 8 250 Ω 4-20mA 13 mV/V input * Time proportional PID relay contact COM 3 output is configured at factory Contact rating: 250 V AC, 3 A before shipment. L 12 + 12 b Default: 1-5 V DC Note: Select this option from the OT1 parameter. Power supply * When receiving 4-20 mA DC current signals, set the PV input type to 1-5 V DC (setpoint “41”). RTD input 12 + Specify in a range of 1-5 V DC, 0-2 V DC, or 0-10 V DC. Control output Relay contact output TC input 11 A 21 + 22 - 26 䊏 Receiving 4-20 mA DC Current Signals with the Controller See Initial Settings User’s Manual . 39 +5V DI5 38 +5V DI5 38 DI6 37 +5V DI7 36 COM 20 Contact rating: 12 V DC, 10 mA or more ■ UP750 Single-loop Heating/Cooling Control (Model UP750-0䊐 or UP750-5䊐) Communication 1 Communication 2 (PSL1) (PSL2) RS-485 communication High performance * Wiring can only be carried out RS-485 communication for controllers with communication functions. 28 RSB(+) 23 SDB(+) 24 IMPORTANT The controller is factory-set to the Single-loop Control type. Change the setting of the Control Output Type (OT1) parameter to the Heating/Cooling Control. Heating-side control output SDA(-) RDA(-) 27 SG 29 RSA(-) 30 SG Auxiliary analog input 21 + 25 RDB(+) 26 * Wiring can only be carried out for controllers with auxiliary analog input. PV input * Not configured at factory before shipment See Initial Settings User’s Manual . Not used in single-loop control. 22 - TC input RTD input 11 A 12 + 12 b 250 Ω 4-20mA 13 - 13 - 13 B Default: 1-5 V DC mV/V input Note: Connecting a 250 Ω resistor to the terminals is optional. Model: X010-250-2 (resistor with M3.5 crimp-on terminal lugs) 12 + 1 NO 2 COM 3 Note: Select this option from the OT1 parameter. 1 41 31 21 11 2 42 32 22 12 13 - Power supply Power supply L 8 N 3 43 33 23 13 4 44 34 24 14 5 45 35 25 15 6 46 36 26 16 7 47 37 27 17 8 48 38 28 18 * Factory-set to “PV retransmission.” Retransmission output 1* 15 V DC loop power supply* CAUTION Before carrying out wiring, turn off the power to the controller and check that cables to be connected are not alive with a tester or the like because there is a possibility of electric shock. Heating-side control output Note: Select this option from the OT1 parameter. * Retransmission output 2 is available only when “relay” is selected as the type of heating-side control output. Current / voltage pulse output 9 49 39 29 19 16 + 10 10 50 40 30 20 17 - UP PV event 1 output DO1 6 0-20mADC, 4-20mADC Voltage pulse (12 V) 17 - Relay Cooling-side control DO3 4 output (Note) Transistor Time event 3 output Time event 4 output Common 0-20 mA DC 4-20 mA DC, voltage pulse (12 V) 15 - 14.5-18.0 V DC (21 mA DC max.) * Retransmission output 1 is not available if a 15 V DC loop power supply is used. * If you define the cooling-side output as current output, retransmission output 1 and the 15 V DC loop power supply can no longer be used. External contact inputs Switch between the ON and OFF states of the DI1 to DI4 contact inputs to select from program pattern numbers 1 to 15. (Select a number during a RESET state.) 2 3 4 5 6 7 8 9 UP DI1 19 10 11 12 13 14 15 DI1 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON DI2 OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON DI2 18 DI3 OFF OFF OFF ON ON ON ON OFF OFF OFF OFF ON ON ON ON DI3 40 DI4 OFF OFF OFF OFF OFF OFF OFF ON ON ON ON ON ON ON ON Relay contact rating: 240 V AC, 1 A 30 V DC, 1 A (resistance load) Transistor contact rating: 24 V DC, 50 mA DI4 39 DO6 32 Start of program operation when DI5 changes from OFF to ON DO7 31 Stop of program operation when DI6 changes from OFF to ON DI6 37 Start of local-mode operation when DI7 changes from OFF to ON DI7 36 Common COM 20 NOTE * The dual-loop type controller (UP750-5ⵧ) only COM 35 14 + * The functions of a contact input can be varied by changing the setting of the contact input registration parameter. 1 DO5 33 14 + 15 - COM 7 Cooling-side control DO4 34 output (Note) Cooling-side control output 0-20mADC, 4-20mADC * The functions of a contact output can be varied by changing the setting of the contact output registration parameter. 4-20 or 0-20 mA DC Default: 4-20 mA DC 16 + Default: 4-20 mA DC Note: If you define the DO3 output as the cooling-side control output, the DO4 output serves as the time event 1 output. Inversely, if you define the DO4 output as the cooling-side control output, the DO3 output serves as the instrument alarm 1 output. PV event 2 output DO2 5 15 - Default: Unspecified retransmission type 9 External contact outputs 14 + Retransmission output 2* Allowable range: 100-240 V AC (10%) (free voltage) 50/60 Hz shared Time event 2 output NOTE Installation category (overvoltage category): II (IEC1010-1) Contact rating: 250 V AC, 3 A 30 V DC, 3 A (resistance load) Common * When receiving 4-20 mA DC current signals, set the PV input type to 1-5 V DC (setpoint “41”). 12 + Specify in a range of 1-5 V DC, 0-2 V DC, or 0-10 V DC. Relay contact output NC 䊏 Receiving 4-20 mA DC Current Signals with the Controller “Current output terminal ( 46 and 47 )” can be used for retransmission output 2. DI5 38 Contact +5V Transistor contact DI1 +5V DI2 +5V DI3 +5V DI4 +5V +5V DI5 DI6 +5V DI7 19 18 40 39 38 37 36 COM * OT1 is a setup parameter. You can change the settings of the parameter OT1 to change the control output type. See Initial Settings User’s Manual 20 Contact rating: 12 V DC, 10 mA or more Correspondence between parameters OT1 and heating side output types/cooling side output types OT1=4 OT1=5 OT1=6 OT1=7 OT1=8 OT1=9 OT1=10 OT1=11 OT1=12 Heating side: Relay output (terminals 1 , 2 and 3 ) Cooling side: Relay output (terminals 4 and 7 ) Heating side: Voltage pulse output (terminals 16 and 17 ) Cooling side: Relay output (terminals 4 and 7 ) Heating side: Current output (terminals 16 and 17 ) Cooling side: Relay output (terminals 4 and 7 ) Heating side: Relay output (terminals 1 , 2 and 3 ) Cooling side: Transistor output (terminals 34 and 35 ) Heating side: Voltage pulse output (terminals 16 and 17 ) Cooling side: Transistor output (terminals 34 and 35 ) Heating side: Current output (terminals 16 and 17 ) Cooling side: Transistor output (terminals 34 and 35 ) Heating side: Relay output (terminals 1 , 2 and 3 ) Cooling side: Current output (terminals 14 and 15 ) Heating side: Voltage pulse output (terminals 16 and 17 ) Cooling side: Current output (terminals 14 and 15 ) Heating side: Current output (terminals 16 and 17 ) Cooling side: Current output (terminals 14 and 15 ) The types of control output, “relay output” and “voltage pulse output” shown in the table above refer to those of time proportional control. To change to a relay output for on-off control, select “Relay Terminals” and change the setpoint of the proportional band to “0.” IM 05E01B02-01E (2)