PROPRIETARY AND CONFIDENTIAL DRAFT 6/29/2006 WARNING: When raising or lowering the incubator, the operator should ensure that both equipment and appendages are clear of the unit’s travel path. Patient and incubator connections must also be checked before adjusting the incubator height. Never place any objects on top of the drawer assembly and always check before lowering the VHA to ensure there is sufficient clearance between the incubator and stand assembly. Do not raise or lower the unit while installing or removing medical gas tanks from the tank holder assembly. Failure to do so could result in personal injury or equipment damage. [IHA011] WARNING: Accessories such as trays, baskets, and shelves should never be overloaded and are not intended to hold an infant. Infant injury could occur. [IHA014] WARNING: Inspect the battery module for possible leakage during service intervals and prior to removal and handling. The battery module is heavy and therefore requires sufficient strength and the proper lift method in order to avoid injury upon removal or installation. Observe local, state, and federal regulations with regards to handling, storage, and disposal of sealed gel cell batteries. [IHA021,033] WARNING: Always close and latch drawers when not in use, particularly when the incubator is being moved. Personal injury could occur. [IHA28] WARNING: To avoid injury or equipment damage, use only Dräger Medical listed latches and accessories with the rail system. It is also important to secure the latch properly to the rail as identified in the manual, as well as periodically check both the operation and retention of the latch to securely hold the accessory being used. When the latch is properly locked, both visual and physical feedback are provided. The toggle handle will snap into an 8 o’clock position on the latch body, when locked. Total rail load must not exceed 36.3 kg (80 lb). The side rail loads must not exceed 13.61 kg (30 lb). The front and rear rail loads must not exceed 6.8 kg (15 lb). [IHA029] WARNING: The drawers and rail system are labeled for acceptable weights.[IHA010] WARNING: Do not insert any object into any of the ventilation holes or any other opening on the uninterruptible power supply (UPS) system. Doing so may cause personal injury or equipment damage. WARNING: Do not add external batteries to the UPS system. Personal injury or equipment damage could occur. WARNING: Do not connect the Isolette® Infant Incubator, Models C2000 or C2000e to a surge suppressor. 3 - 10