Transcript
90 Installation / Dish Assembly GROUNDING CONDUCTOR MOUNTING HOLES Figure 75, Attaching Grounding Conductor to Mounting Foot The National Electrical code is also very specific on acceptable electrodes ground. Some possible grounding electrodes are: for the Grounded Interior Metal Water Pipe (cold water). Ground Rod (must be driven at least 8 feet into the ground). Grounded Metallic Service Raceway. Grounded Electrical Service Equipment Enclosure. There are also specific instructions for the correct method of attaching to each ground electrode to the ground conductor. For more details on each of these grounding electrodes, consult the National active codes in your area. Electrical Code handbook and any Note: Appendix C of this manual contains sections of the National Electrical Codes that apply to the installation DSS system. There are two holes in the mounting foot for connecting a ground conductor. Hardware (a nut, bolt, and star washer) to connect the ground conductor to the foot is included in the hardware package. Use the Following steps to connect the mast to a grounding electrode: 1. Attach the grounding conductor to the mounting foot with a bolt, nut, and star washer.