Download Hong Yu Da
Transcript
Shenzhen HongYuDa CNC Technology Co.,Ltd. 4.2. Settings of XPTHC-200 4.2.1. Settings of ascending speed XPTHC-200 sets manual and outer controlled ascending speed through two-band switch SUP1 (on the arc voltage control panel), but ascending speed in automatic mode are not related with the settings. It is only related with the settings of sensitivity. See figure 4-3 SDN1 descending speed setting switch 2# control logic chip SUP1 ascending speed setting switch SDL1 positioning speed setting switch 1# control logic chip Figure 4-3: location of speed setting band switch 16