Download Test Waters
Transcript
Results and computation Record the Oocystson the slides of input and output samples and convert them into Oocystsper liter of sample. Live cyst reduction can be calculated by subtracting the number of live cysts of output/L from live cyst of input/L The oocystinactivation is expressed as log reduction and is calculated asLive Oocystlog reduction = Log10 (value of live oocystsin input)/ L – log10(value of average live oocystin output)/ L. [(Count of live oocysts in O-1+ O-2+ O-3)*1000/ (total volume of sample tested O-1+ O-2+ O-3)]. The microbiological water purifier must demonstrate 3 Log10 reduction in the viability of Cryptosporidiumparvumoocysts.