Download F Note

Transcript
380
CANSAS Users Manual
General Technical Specs
General technical specs
· Built-in signal processor for online data compression, filtering, statistics and generation of virtual
channels.
· Configurable by means of optional configuration software.
· Synchronized sampling of all measurement channels.
· Automatic activation upon application of supply voltage.
· 16-bit resolution.
· Number of virtual channels <100. Depending on the module, a certain number of virtual channels are
already used internally. Those channels reduce the number of available virtual channels.
· Operating temperature -30°C to 85°C, condensation allowed. (unless otherwise indicated)
· Shock resistance 50g pk over 5 ms (without connector pods).
· Isolation strength to power supply and CAN-bus: ± 50 V (unless otherwise indicated)..
· TEDS base isolation
· Power supply 10 V to 50 V DC except from BRIDGE2, CANSER, C12 and ISO8: 9 V to 32 V DC. Modules
build before April 2011: 9 V to 32 V, see specification label.
· power consumption 4W (unless otherwise indicated)
Unless otherwise indicated, the technical specs given are valid for the following ambient conditions:
· temperature 23°C
· air pressure 1013 mbar
· relative humidity 40%
CANSAS Users Manual Manual version 1.7 Rev 2