10. Other Operation Functions
10. Other Operation Functions
10.1 Position Table(PT) Operation Example
Input ‘PT A0~ PT A7’ signals to set PT number. Input ‘PT Start’number to execute
speed control operation. For more information, refer to 「User Manual – Position Table
Function」.
【Position Table Setting 】
PT
No.
Command
type
Position
Low
Speed
High
Speed
Accel.
time
Decel.
time
Wait
time
Continuous
Action
JP Table
No.
0
1
2
3
3
3
3
3
10000
1000
5000
-2500
1
1
1
1
2500
500
1500
1000
50
50
300
300
300
300
0
0
300
0
1
1
0
0
1
2
3
-
10.2 Jog Operation Example
The machine executes speed control operation at the speed set by parameters a ccording to
inputting ‘Jog+’ and ‘Jog-‘ signals.
【Parameter Setting 】
No.
6
7
8
Parameter Name
Jog Speed
Jog Start Speed
Jog Acc Dec Time
Setting Value
1500
100
200
www.fastech.co.kr
Unit
[pps]
[pps]
[msec]
51