P30U-09A/1
USERS MANUAL
Route of the interface line is presented in the Fig. 3. In order to obtain
correct transmission, it is necessary to connect the lines A and B in parallel
to their equivalents in other devices. Connection should be made with a
shielded cable. The cable shield should be connected to the protective
terminal as close to the transducer as possible (the shield is to be
connected to the protective terminal at one point only).
GND line is intended for additional protection of the interface line in case of
long connections. Then you should connect the GND signals of all the
devices on the RS-485 bus.
In order to get connected with a computer you must have the RS-485
interface card or an appropriate converter such as PD51 or PD10. The
method of connecting the devices is presented in the Fig. 23.
Fig.23. Method of connecting the RS-485 interface.
Designation of the transmission lines for the card in a PC computer
depends on the card manufacturer.
51