Transcript
CBECC-COM User Manual 2013 Version 1f Electric Use section IntPDReg: Total regulated connected lighting power density for all interior lighting systems in a Space. This includes the loads for lamps and ballasts. Schedules (IntPDReg): Reference to a schedule that describes the fraction of lighting use on an hourly basis. Fraction to Space (IntPDReg): Fraction of regulated interior lighting heat gain going to space air. Radiant Fraction (IntPDReg): Fraction of regulated interior lighting radiant heat gain going to space surfaces. IntPDNonReg: Total non-regulated connected lighting power density for all interior lighting systems in a Space. This includes the loads for lamps and ballasts. Schedules (IntPDNonReg): Reference to a schedule that describes the fraction of lighting use on an hourly basis. Fraction to Space (IntPDNonReg): Fraction of non-regulated interior lighting heat gain going to space air. Radiant Fraction (IntPDNonReg): Fraction of non-regulated interior lighting radiant heat gain going to space surfaces. RecptPwrDens: The usage of electrical devices plugged into receptacles in a space based on the occupancy type. Schedules (RecptPwrDens): Reference to a schedule that describes the fraction of receptacle use on an hourly basis. ProcElecPwrDens: Process electrical power density resulting from an activity or treatment not related to the space conditioning, lighting, service water heating, or ventilating of a building as it relates to human occupancy. Process load may include sensible and/or latent components. For data centers this includes transformers, UPS, PDU, server fans, power supplies, etc. Schedules (ProcElecPwrDens): Reference to a schedule that describes the fraction of receptacle use on an hourly basis. RadFrac (ProcElecPwrDens): The fraction of radiant heat gain to a space based on appliance energy use. LatFrac (ProcElecPwrDens): The fraction of latent heat gain to a space based on appliance energy use. LostFrac (ProcElecPwrDens): The fraction of heat lost to the exterior is based on appliance energy use. RfrgPwrDens: The amount of power supplied to a unit area for refrigeration. Schedules (RfrgPwrDens): Reference to a schedule that describes the fraction of refrigeration use on an hourly basis. Natural Gas Use section GasEqpPwrDens: Commercial gas power density is the average power density for all commercial gas equipment, assuming constant year-round operation. Schedules (GasEqpPwrDens): Reference to a schedule that describes the fraction of gas equipment use on an hourly basis. ProcGasPwrDens: Process load is the gas energy consumption in the conditioned space of a building resulting from an activity or treatment not related to the space conditioning, lighting, service water heating, or ventilating of a building as it relates to 63