Download AXIS AX-7 Cobra+ - Technical Reference

Transcript
THE PARAMETER LIST
#100 Option Select 3 (continued)
Bit 2 ($04):Valid Form Feed Positions
Value Description
*0
1
Notes:
FF is valid at 1st print position and MPP+1
FF is valid anywhere
1. This switch is used in DSC/DSE mode only.
2. This switch emulates an IBM RPQ.
Bit 3 ($08): Automatic Function at End of Job
Value Description
*0
1
Notes:
NL is generated at end of print buffer
FF is generated at end of print buffer
1. This switch is used in DSC/DSE mode only.
2. This switch emulates an IBM RPQ.
Bits 4 - 6 ($10 - $40): Reserved
Bit 7 ($80): Space as delimiter
Value Description
*0
1
Spaces can not be used as delimiter in ext. emulation sequences
Spaces can be used as delimiter in ext. emulation sequences
#102 Physical Maximum Print Position
Selects the physical paper width for Right-to-Left print mode.
Value
Description
0 - 255 Physical paper width (max. print position)
*132
Factory default value
Notes:
Related
parameters:
1. This parameter is only active when an Arabic or Hebrew Code Page and ASCII
Character Set is selected.
#003 Maximum Print Position
#063 ASCII Character Set
#005 System Language
#065 Right-to-Left Mode Sequence
Axis AX-7 Cobra+ Technical Reference
92