Download CAR-14 - MICRO-AIDE

Transcript
CAR‑14 U ser M anual
1. Establish a Telnet connection with the Reporter using HyperTerminal or Tera Term. Refer to the section
entitled “Connecting Remotely” on page 36.
2. Log on to the Reporter. From the Main Menu select the Remote Port command. The following menu
will be displayed.
Remote Menu
S Setup Remote Port
A Access Remote Port
Remote Port Command
3. Select the Setup Remote Port command. The following menu will be displayed.
Remote Port
----------Terminal Port Baud Rate
9600
Terminal Port Mode
Remote
4. Move the highlight to the Terminal Port Mode field. Press the Spacebar once. The setting will change
to Terminal. Remote Port Mode is now disabled and Terminal Port Mode resumes.
If no further alternate device sessions are required, the user may wish to disconnect the cable between
the Terminal Port and alternate device. The port will again be available to a local PC user.
F ront P anel C ontrol
of
R emote P ort M ode
Remote Port Mode can also be enabled and disabled by pressing the Maintainer Mode PB switch for
10 seconds without interruption. The status will toggle with each successive action. Refer to the section
entitled “Control of Remote Port Mode” on page 36 for additional details.
4
L ive S tatus (L)
The Live Status feature provides the user with a continuously updated view of Alarm and Input status. It
utilizes a single screen to convey Alarm, Digital, Analog and Virtual Input information.
To view the status information, select the Live Status command from the Main Menu. Data similar to
the following will be displayed. Union Pacific’s c14sear2.v100 Setup Database was used to provide the
sample data.
[ESC]=exit
L01:
L02:
L03:
L04:
L05:
L06:
L07:
L08:
L09:
L10:
L11:
L12:
L13:
L14:
L15:
L16:
L17:
L18:
L19:
L20:
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
1B
2B
3B
4B
PR
PR
AR
TN
GC
LA
Live Status
XR
: Off
B1
D2
: Off
B2
AnaFail : Off
B3
HiTemp : Off
B4
GateProb: Off
D6
: Off
V1
D7
: Off
V2
D8
: Off
V3
D9
: Off
V4
POR
: On
V5
V6
V7
V8
Live Status Command
40
M icro ‑A ide
:
:
:
:
:
:
:
:
:
:
:
:
11:17:20 06-04-12
Off
Off
Off
Off
13.1Vdc
13.9Vdc
0.0Vdc
0.0Vdc
Off
Off
Off
Off
Off
Off
Off
Off