Download GM-2730S User Manual

Transcript
GOSPELL Digital Technology Co., Ltd
Multifunctional ASI+IP-to-IP
Adapter
GM-2730S
User Manual
GOSPELL Digital Technology Co., Ltd
-1-
GOSPELL Digital Technology Co., Ltd
Safety Instructions
Read this manual carefully before start operating the device.
Removal of device cover without permission may cause harm to human body and
the maintenance bond will be invalidated.
Handle the device with care to avoid crashing and falling, or otherwise it may cause
hazards to the internal hardware components.
Keep all inflammable, metal and liquid materials from dropping into the device
casing, or otherwise it may cause damages to the device.
Avoid dusty places and places with heating resources nearby, direct projection of
sunlight or instant mechanical vibrations for installation of the device.
Connect the grounding connector on the rear panel to protect earth contact
properly while in operation.
Choose proper type of cable connectors for connecting network interfaces of the
device.
Avoid rapid and frequent power on/off, or it may cause damages to the
semiconductor chipsets.
Keep proper direction of the power cord when plug into or out from a power socket.
Do not touch the power socket with wet hands to avoid electric shocks.
Take off all jewelry or ornaments, such as ring, necklaces, watches, bracelets, etc.,
before operating the device, or otherwise the metal contact may possibly cause
short circuit and result in components damage.
Make sure the AC power is unplugged in case of operator services within the
device casing or close to power supply are needed.
Only GOSPELL trained and approved staff is permitted to perform live line
operation and maintenance within the device casing.
Ensure good ventilation when the device is in operation, or otherwise it may cause
damages to the device due to overheating.
It is recommended to unplug the power cord from the socket if the device will not be
used for a long period of time.
-2-
Table of Contents
Safety Instructions ........................................................................................................................- 2 - Table of Contents .............................................................................................................................. 3 §1 Introduction ................................................................................................................................. 5 §1.1 Functionality ..................................................................................................................... 5 §1.2 Key Features ..................................................................................................................... 5 §1.3 Front Panel ........................................................................................................................ 5 §1.4 Rear Panel ......................................................................................................................... 6 §1.5 Typical Application Architecture ...................................................................................... 7 §2 Before Use the Device ................................................................................................................. 8 §2.1 Operation Requirements ................................................................................................... 8 §2.1.1 Requirements for Digital TV Devices ................................................................... 8 §2.1.2 Requirements for Network Devices ....................................................................... 8 §2.2 System Requirements ....................................................................................................... 8 §3 Operating the Device ................................................................................................................... 9 §3.1 Quick Start ........................................................................................................................ 9 §3.2 Web Management Operation of GM-2730S ................................................................... 10 §3.2.1 Web User Login ................................................................................................... 10 §3.2.2 User Management ................................................................................................ 12 §3.2.2.1 Add new user ............................................................................................ 13 §3.2.2.2 Edit users’ information .............................................................................. 14 §3.2.2.3 Delete a user.............................................................................................. 14 §3.2.3 Basic parameter setting ........................................................................................ 15 §3.2.3.1 IP setting ................................................................................................... 15 §3.2.3.2 MAC address setting ................................................................................. 16 §3.2.3.3 Parameter setting about system clock ....................................................... 16 §3.2.4 Advanced Parameter setting................................................................................. 17 §3.2.4.1 Import/export/reset the parameters ........................................................... 17 §3.2.4.2 Back-up/recover the parameters ............................................................... 20 §3.2.4.3 Upgrade/back-up the software .................................................................. 20 §3.2.4.4 Device control ........................................................................................... 22 §3.2.5 SNMP Settings ..................................................................................................... 23 §3.2.6 Input/output setting .............................................................................................. 24 §3.2.6.1 Enquiry of ASI interface status ................................................................. 24 §3.2.6.2 Enquiry and settings for IP Input Interface Status .................................... 24 §3.2.6.3 Enquiry and Settings for IP Output interface status .................................. 25 §3.2.7 Multiplexing setting of Programs ........................................................................ 27 §3.2.7.1 General setting .......................................................................................... 27 §3.2.7.2 PID mapping function ............................................................................... 29 §3.2.7.3 PSI information insertion .......................................................................... 31 §3.2.7.4 Output service ........................................................................................... 35 §3.2.7.5 Batch output services settings ................................................................... 39 §3.2.8 Monitoring ........................................................................................................... 41 §3.2.8.1 Alarms ....................................................................................................... 41 §3.2.8.2 Bitrate Monitor ......................................................................................... 43 §3.3 Front Panel Operation of GM-2730S.............................................................................. 49 GOSPELL Digital Technology Co., Ltd
Annex A: Technical Specifications ................................................................................................. 51 Annex B: Frequently Asked Questions.......................................................................................- 53 - Postscript ........................................................................................................................................ 54 4
GOSPELL Digital Technology Co., Ltd
§1 Introduction
§1.1 Functionality
GM-2730S is a new generation of ASI+IP-to-IP adapter for transforming MPTS to SPTS, which has
eight channels of ASI inputs, IP inputs, and multiplexes. It adopts our newly developed functions
such as “Module Management”. The flexible customization and high expansibility can satisfy the
user’s current and future DTV system requirements.
The product is applied mainly to the DTV network head end room, edge of DTV backbone network,
and DTV branch head end room.
§1.2 Key Features
This product has the following key features:
8 ASI inputs, 120 IP inputs
450 IP outputs
IP output data rate range: 1~800Mbps
Support multiplex via IP interface output
Payload of UDP: 7 of 188-byte-length TS packets
Support multiplex and PSI/SI process
Support up to 512 program multiplexed
Support SI/PSI auto-generation during multiplexing
Support auto-generation of network information
Support PID filtering and mapping
Data input and output parameters can be flexibly configured and it can auto-detect the input bit
stream
Support many network protocols, such as UDP、ARP、ICMP、IGMP
Support HD/SD program transmission
Support Web/SNMP-based management and online remote update
Support both Chinese and English in web page and related technical document
Power-failure memory recovery
Support device configuration import/export
Powerful background configuration function and web monitor system, ensure the device’s high
stability
§1.3 Front Panel
As shown in figure 1, there are one LCD display、one 6-key keypad and three LED indicators on the front
panel of GM-2730S.
The model type and logo notification information will be displayed on the LCD screen during the device
initialization stage. User can check part of the working status of device, and set part of the parameters of
GM-2730S by exploring a menu realized by buttons/LCD screen after system initialization, see section
§3.3 for details.
5
GOSPELL Digital Technology Co., Ltd
The POWER LED will be light if the device powers on successfully.
The STATUS LED will show some working status of the device, see section §3.3 for details.
The ALARM LED will indicate warning messages of the device, if exists, see section §3.3 for
details.
Fig.1 Front Panel View of GM-2730S
§1.4 Rear Panel
As shown in figure 2, the rear panel of GM-2730S consists of one power supply connector, one power
switch, one RJ45 connector for management, eight BNC ASI connectors for data input, one RJ45
connector for data output, and a grounding point.
Power Input Port: To connect to 100~240V 50/60Hz AC input;
Power Switch: To turn GM-2730S on or off;
Management Port: RJ45 interface, to connect to management server via 100BaseT or Gigabit
Ethernet;
Data Input/Output Port: RJ45 interface, to connect to switches via Gigabit Ethernet;
ASI Input Port: BNC-Female port, to connect to any ASI output device via ASI cable;
Grounding Point: To connect the device with conductive earth. Please make sure of proper
grounding of the device before start operating it for the safety of the operators and the device
itself!
Fig.2 Rear Panel View of GM-2730S
6
GOSPELL Digital Technology Co., Ltd
§1.5 Typical Application Architecture
Fig.3 System Application Block Diagram of GM-2730S
7
GOSPELL Digital Technology Co., Ltd
§2 Before Use the Device
§2.1 Operation Requirements
I In order to ensure proper operation of GM-2730S, there are some requirements for other digital TV and
network devices, which will connect with GM-2730S. Please see below for details:
§2.1.1 Requirements for Digital TV Devices
The output or input transport streams of the devices, which will provide signal source to or receive signal
from GM-2730S should comply with the following standards:
Transport Stream (TS): This means that the TS stream with one or more channels of digital TV, digital
audio broadcasting or any other digital TV services should comply with DVB standard; it must contain
PAT and PMT tables, which can completely describe the services.
For GM-2730S, the TS packets must be encapsulated into UDP datagram. Each output TS should have
unique destination IP address (unicast or multicast) and port number. The length of the UDP payload
must be 7*188Byte (TS packets), and the payload must be synchronized by sync byte 0x47.
GM-2730S may be able to receive/feed multiple transport streams from/into any devices with the TS
format complies with the above-mentioned format.
§2.1.2 Requirements for Network Devices
The switch used for the GM-2730S data output and its destination devices’ (the IPQAM modulator shown
in figure 3) output port switch (the “gigabit switch” in figure 3) must be a Layer 3 gigabit switch which can
be managed, indispensability to support IGMP2.0. The backboard exchange speed must be higher than
10Gbps; the maximum throughput of each port must be higher than 1Gbps.
The switch for the GM-2730S and the managing workstation should be a 100M or gigabit switch, the
maximum data exchange speed of each port must be higher than 40Mbps. Normally, It can be the same
switch with GM-2730S’s output data switch, the two ports need to be configured to different VLANs.
Any hosts that may worsen the network traffic, such as some workstations or servers installed real-time
communication tools, streaming media server or WEB server, must not be located at the LAN switch of
the output of GM-2730S. These additional signals may cause packet loss, network jitter worsening, and
hence due to audio/video distortion at the audiences.
§2.2 System Requirements
Management workstation must have network connection and support TCP/IP protocol. Microsoft
Windows 2000/XP (or higher versions) and Internet Explorer 6.0 (or higher version) are the
recommended operating systems of the management workstation, and JavaScript must be supported by
the web browser.
8
GOSPELL Digital Technology Co., Ltd
§3 Operating the Device
§3.1 Quick Start
Please follow the procedures below if it is the first time for you to use GM-2730S for constructing DTV
head-end system:
1、 Construct your hardware environment, including chassis installation, power supply system
deployment, and connecting switches, GM-2730S, the preceding device(s)(e.g. IRD, encoders,
etc.), the succeeding device(s), management workstation properly .
2、 Plan for the IP addresses of management port and data port, the cable connectors (coaxial cable,
Gigabit network) of each preceding/succeeding devices; as well as number of digital TV
transport streams and their output channels. It is recommended to take remark of device
addresses, port numbers and other configurations and keep it safely for checking purposes in
future.
3、 Boot up each preceding devices of GM-2730S and configure the operating parameters, in order
to ensure the proper signal receiving/decoding or output of encoded digital TV transport streams.
Please refer to the user manuals of preceding devices provided by their suppliers for detailed
configuration.
4、 Boot up GM-2730S, If you have known the management port IP address of the GM-2730S you
are currently using, and it is in the same subnet with the management workstation, you may also
start configuring GM-2730S from the management workstation directly. Or otherwise you will
need to configure the IP address of management port using front panel control (refer to section
错误!未找到引用源。)
5、 Login to the web browser from the management workstation, key in the default user name
“admin” and password “000000”; add and configure usernames and passwords of users allowed
to access the device (refer to section§3.2.2 )
6、 Configure the input and output data port(refer to section§3.2.2 )
7、 Search for input programs tree (refer to section §3.2.7.3), configure the output program settings,
including: select input program for output stream(refer to section 错误!未找到引用源。),
configure the ES PID, SI/PSI version number of each program, and configure the auto-generated
SI parameters or upload SI segments output program parameter (refer to section 错误!未找到
引用源。); if needed.
8、 Configure the SNMP parameters if needed. (refer to section 错误!未找到引用源。).
9、 Configure the data IP address of GM-2730S’s preceding devices. The work parameter setting of
GM-2730S’s succeeding device refers to the user manuals provided by their suppliers.
10、 Make use of stream analyzer to test the system. If the device works properly and the output
signal can be received, then it is ready for transmission in the real network
9
GOSPELL Digital Technology Co., Ltd
§3.2 Web Management Operation of GM-2730S
Monitoring and control of GM-2730S can be performed through Web browser. We recommend you to
use Microsoft Internet Explorer 6.0 or above and set your screen resolution to 1152 * 864.
§3.2.1 Web User Login
After launching the Web browser, key in the IP address of GM-2730S’s management port into the
Address bar of Web browser. Embedded Web server of GM-2730S will prompt with username and
password for authentication, as shown in the figure below:
Fig.4 Web Login
There is a factory default administrator user “admin” in GM-2730S with password of “000000”. Please
use this user and password to login to the system for the first time operation of GM-2730S. But changing
password for this user is strongly recommended, and the new password should be kept safe. If you
choose “remember my proof”, you needn’t input your user and password when you login in the next time.
But to ensure the safety, please do not choose this option in the public server.
The default state of Web management page is in English. If you want to use Chinese, please set the
language to Simple Chinese by changing the operation language in the pull-down list in the home page.
Fig.5 Login navigation
Fig.6 Operation language pull-down list
When you set this to Chinese, if there isn’t any Chinese font library in your operation system, maybe
some unreadable codes appear in your page.
After successfully logging into the system, browser will display the default page of GM-2730S, as shown
in the figure below:
10
GOSPELL Digital Technology Co., Ltd
Fig.7 Default Page
In the default page, there is the information of device (model, serial number, etc), authorization state,
and some important specifications will be refreshed in real time. You could enter into the “device
monitoring”, “Input & Output”, “program multiplexing”, “program scrambling”, “device setting” page by
clicking different hyperlinks in the area of main-menu across the top of this page.
Remark: Device will not autosave your parameters. If the device restarts, the
parameters will change to the state which you saved last time. If you have never
saved your parameters, all the parameters will change to the default state. So if you
want to save your own parameters, please click
after you finish setting GM-2730S.
11
in lower right corner
GOSPELL Digital Technology Co., Ltd
§3.2.2 User Management
We recommend you to change the user and password after login by the default user and password for
the safety. You can edit your user information in the user management page.
Click “device setting” in the home page, and then you have the device setting page, as shown in the
figure below:
Fig.8 Device setting page
Click “user management”
in the “select option” area on the left side of this page, and
then you have the user management page, as shown in the figure below:
12
GOSPELL Digital Technology Co., Ltd
Fig.9 User management page
In this page, you could add new user, edit old users’ information or delete a user.
Remark: Only “admin” user could enter into the user management page.
§3.2.2.1 Add new user
In the area of “adding user”, please input correctly users’ user and password, and then confirm the
password.
After finishing these steps, click “submit” to add a new user. If you add successfully a new user, there will
show your user information on the right side, as shown in the figure below:
13
GOSPELL Digital Technology Co., Ltd
Fig.10 new user information
Remark: All new users are normal users. They are only permitted to set different parameters, but they
don’t have the right to manage the other user or upgrade the system.
§3.2.2.2 Edit users’ information
In the user information list in this page, you can edit a user by clicking the modification button in the
same row.
That makes you edit your password, as shown in the figure below:
Fig.11 Edit users information
In this bar, you can edit your user’s password and that will be accomplished by clicking “submit”.
Remark: You could not delete the “admin” user, but you can change the password for this user.
When you use GM-2730S for the first time, you should change admin’s password at first and then save
this password.
§3.2.2.3 Delete a user
In the user information list in this page, click the “delete” button in the same row to delete this user.
Remark: GM-2730S will not permit you to delete admin user but the normal user..
14
GOSPELL Digital Technology Co., Ltd
§3.2.3 Basic parameter setting
In the system setting page, click “basic setting” in the “select option” area
To enter basic parameter setting page, as shown in the figure below:
Fig.12 basic parameter setting page
In this page, you could accomplish the setting of IP address, MAC address, set the IP address of time
synchronization server, open or close this service, and set the UTC time synchronization, etc.
§3.2.3.1 IP setting
In the page of figure 12, input a right IP address in the “IP setting” bar, then click “submit” to set
GM-2730S’ network parameter.
15
GOSPELL Digital Technology Co., Ltd
Remark: To ensure the working of device, you should guarantee that the management port IP address
and GM-2730S’ management server IP are in the same network segment
§3.2.3.2 MAC address setting
In the page of figure 12, input a right MAC address in the “MAC setting” bar, then click “submit” to set
GM-2730S’ MAC address.
Remark: Gospell’s products have the first 3 bytes “00:5C:B1” in the MAC address, that shouldn’t be
modified.
§3.2.3.3 Parameter setting about system clock
Set time synchronization server: In the page of figure 12, you can set IP address of network clock
server, auto synchronization time lag, auto synchronization switch in the “time synchronization protocol”
bar.
Remark: When you set a right network clock server address, GM-2730S will update his system clock
with the period which the user sets if SNTP service and network clock server are enabled.
Set system clock by manual operation: In the page of figure 12, you can set manually the system
clock in the “date/time(UTC)” bar. And you can also click ”get UTC time”, then click ”submit” button to
finish setting.
Remark:
1. If the network clock server address has already configured and enabled, and the SNTP server works
properly, the device will get the system clock from the network clock server, at this time, the manually
configured clock will be invalid.
2. The device will keep the system clock according to its internal circuit after each manually
configuration; this clock circuit can work properly over two years without the external power supply.
3. Select the synchro-browser UTC clock to be the standard UTC(0 zone) clock, and this clock may be
different from the clock shown on server, e.g. if the server clock is UTC+8:00, the final clock will be
differ about 8 hours.
16
GOSPELL Digital Technology Co., Ltd
§3.2.4 Advanced Parameter setting
In the “system setting” page, click “Advanced setting” in the “select option” area
To enter the parameter setting page, as shown in the figure below:
Fig.13 Advanced setting page
In this page, you could import/export/reset the parameters, back-up/recover the parameters,
upgrade/back-up the software, import the authorization document, restart the device, etc
§3.2.4.1 Import/export/reset the parameters
Import the parameters: In the page of figure 14, click “browse” button in the “import/export/reset the
parameters” bar to choose the parameters’ document of the device.
17
GOSPELL Digital Technology Co., Ltd
Fig.14 Import/export/reset the parameters page
After choosing the parameters’ document, click “Open” button. Then return to last page, click “import”
button, system will change the page to uploading management page, as shown in the figure below:
System will checkout the uploading document, if its format is right, there will appear
mark in the
“uploading” bar and “document checkout” bar. Click “submit” button, you’ll have this dialog box:
Click “OK” button to import the parameters.
Remark:
1. Please do not turn off the device or pull the power off when the device is importing the
parameters.
2. The device will restart after importing the parameters.
Export the parameters: In the page of figure 14, click “export” button, then you’ll have this dialog box:
18
GOSPELL Digital Technology Co., Ltd
Click “save” button to choose the path you want to save these parameters. 2730S
Export the XML:
In the page of figure 14, click “export XML” button, then you’ll have this dialog box:
Click “save” button to choose the path you want to save these parameters.
Reset the parameters: In the page of figure 14, click “reset” button, then you’ll have this dialog box:
19
GOSPELL Digital Technology Co., Ltd
§3.2.4.2 Back-up/recover the parameters
Back-up the parameters: In the page of figure 15, there is a “parameter back-up/restore” bar:
Fig.15 “parameter back-up/restore” bar
Fill in the “input parameter description information” (just like 2012-10-26), click “back-up” button, you’ll
have this dialog box:
Click ”OK” button, system will create a new back-up document. In the same time, “input parameter
description information” will show you the new back-up document’ description, as shown in the figure
below:
Remark: System could only save a unique back-up document each time, the new back-up document will
cover the last one.
Recover the parameters: When the device has a back-up document, click “recover” button, you’ll have
this dialog box:
Click “OK” button to import the parameters
§3.2.4.3 Upgrade/back-up the software
As shown in the figur16, you can choose the upgrade document in the “software upgrade/back-up” bar,
then import it to upgrade the device.
20
GOSPELL Digital Technology Co., Ltd
Fig.16 Software upgrade/backup page
Click “browse” button, you’ll have the file selection box:
Select the upgrade document, click “Open” button, as shown below:
Click “upgrade” button, system will change the page to uploading management page, as shown below:
System will checkout the uploading document, if its format is right, there will appear
mark in the
“uploading” bar and “document checkout” bar. Click “submit” button, you’ll have this dialog box:
Click “OK” button to upgrade the device.
After upgrading, you can check the device version information in the “device information” bar.
21
GOSPELL Digital Technology Co., Ltd
Remark:
1.
2.
Please do not turn off the device or pull the power off when the device is importing the
parameters.
The device will restart after importing the parameters authorization
§3.2.4.4 Device control
As shown in the figure 17, there is a “restart” option in the “device control” bar.
Fig.17 Device control page
Click “restart” button, you’ll have this dialog box:
Click “OK” button, to restart the device.
22
GOSPELL Digital Technology Co., Ltd
§3.2.5 SNMP Settings
Click “SNMP Settings”
in select items of “System Settings” to enter the SNMP page:
23
GOSPELL Digital Technology Co., Ltd
§3.2.6 Input/output setting
Click “Input/Output” hyperlink in the navigation menu of the home page to input/output setting page of
GM-2730S. The number and the name of input/output channel of the device is listed in the “Select Items”
in the left side of this page, as shown below
Fig.18 List of the input/output channel
§3.2.6.1 Enquiry of ASI interface status
Click “ASI” hyperlink as shown above, the status of ASI interface is shown in the right side of the main
page, as shown below:
Remark: the number and type of interface are subject to the available products.
§3.2.6.2 Enquiry and settings for IP Input Interface Status
Click “Input channel 02 Ethernet” hyperlink as shown in figure below. The Ethernet interface parameters
24
GOSPELL Digital Technology Co., Ltd
are shown in the channels setting page, as shown below:
Ethernet parameters:
IP address, subnet mask, gateway and MAC could be configured.
Channel parameters:
In the Ethernet interface parameters setting menu, user can set such as protocol interface type, source
IP address and port, input switch parameters.
Parameters setting range:
Protocol type: UDP/RTP
Source IP address: 001.000.000.000~126.255.255.255 and 128.000.000.000~239.255.255.255”
Source port: 1000~65535
Input switch: ON/OFF
After IP channel parameters are setting OK, click “Submit” button at right-bottom of the page to save the
setting.
§3.2.6.3 Enquiry and Settings for IP Output interface status
Click “Ethernet” hyperlink under “output channel” to enter the following interface (the interface name is
subject to the available products):
25
GOSPELL Digital Technology Co., Ltd
Channel parameters:
In the Ethernet interface parameters setting menu, user can set such as protocol interface type, source
IP address and port, input switch parameters.
Parameters setting range:
Protocol type: UDP/RTP
Source IP address: 001.000.000.000~126.255.255.255 and 128.000.000.000~239.255.255.255”
Source port: 1000~65535
Input switch: ON/OFF
After IP channel parameters are setting OK, click “Submit” button at right-bottom of the page to save the
setting.
26
GOSPELL Digital Technology Co., Ltd
§3.2.7 Multiplexing setting of Programs
Click “MUX Setting” hyperlink in the navigation menu of the home page to Multiplexing setting page of
GM-2730S, as shown below:
Fig.19 Multiplexing setting of programs
The multiplex parameter configurations are listed in the “Select Items” in the left side of this page,
including the general setting, manual PID map, manual PSI inserter, NIT edit, input programs and output
programs.
Fig.20 List of the multiplex parameter configurations
§3.2.7.1 General setting
Click “General Setting” hyperlink, the basic information of the system is displayed in the right side of the
page, as shown below:
27
GOSPELL Digital Technology Co., Ltd
Fig.21 Base setting of program multiplexing
The default of input/output character-sets, time zone and TDT/TOT can be set in this page.
§3.2.7.1.1 The setting of the default character-sets
The character-sets setting and transform functions built in GM-2730S to ensure the received program
information over transport stream can be displayed correctly, meanwhile ensure this information can be
displayed correctly in the next device.
It can be set in the column of default character-sets of input/output.
There are 3 kinds of character-sets:LATIN、GB2312、UTF-8
§3.2.7.1.2 Setting of time zone
Setting of time zone affect TOT table, after analyze the TOT table at the receiver side, the receiver can
get this time zone.
28
GOSPELL Digital Technology Co., Ltd
§3.2.7.1.3 Setting of TDT、TOT
The TDT table update cycle and TOT switch can be set in the column of TDT/TOT setting.
TDT update cycle(per second): update the TDT table with cyclical time.
TOT switch: set it on, the device insert TOT table in the sent transport stream.
After the configuration, click “Submit” button at right-bottom of the page to save the setting.
§3.2.7.1.4 Setting of SDT Switch
Select ON or OFF in SDT switch bar, and then click the “submit” button to complete the setting.
§3.2.7.2 PID mapping function
The system will discard the private PID, if it cannot be identified. The needed private PID can be mapped
by the PID mapping function, and mapped private PID can be passed through and transmitted by the
device.
§3.2.7.2.1 Add new PID mapping function
As shown in figure 21, click “Manual PID Map” hyperlink, the PID mapping setting page will display in the
right side. The following figure shows the “PID mapping” page:
29
GOSPELL Digital Technology Co., Ltd
Fig.22 PID mapping
Click “add” button in the bottom of this page, a new column of PID parameter setting will display, as
shown bellow:
Input TS index: choose the input TS channel from 1 to 16.
Input PID: select the PID, which is needed to map.
Output TS index: choose the output channel from 1 to 8.
Output PID: set a PID number from the input PID.
Switch: switch on, the selected PID will map to selected channel.
After the configuration, click “Submit” button at right-bottom of the page to save the setting.
Remark:
1. When the input TS index is out of the boundary, the operation will failure.
2. When the output TS index is out of the boundary, the operation will failure.
3. The input/output PIDs are decimal number
§3.2.7.2.2 Delete PID mapping
30
GOSPELL Digital Technology Co., Ltd
As shown above, select the check box in any column, after that click the “Delete” button in the bottom of
this page, then, click “Submit”, the selected PID mapping will be deleted.
As shown above, the second PID mapping has been deleted.
§3.2.7.3 PSI information insertion
As shown in figure 23, click “ ” button, which at the left side of the “input program” hyperlink, the input
program menu spread up, as shown below:
Fig.23 Input program menu
The type of the current input channel is displayed in the input program menu. As shown in figure 24,
spread “channel 01” menu, the number of this type of channel can be checked.
Fig.24 Input channel list
As shown in figure 24, click any hyperlink of channel (i.e.: “TS 0100”), the input TS program information
can be checked at the right side of the page.
31
GOSPELL Digital Technology Co., Ltd
Fig.25 Input TS program information
§3.2.7.3.1 Program search
As shown in figure 25, click
button at the bottom of the page, the system will search
the corresponding channel automatically, and display the information, as shown below:
Fig.26 Input program information
§3.2.7.3.2 Program information check
32
GOSPELL Digital Technology Co., Ltd
The information of the TS is displayed above the program list, as shown below:
Fig.27 TS information
Click any “ ” button at the right side of the program name, the details spread up below:
Fig.28 Program TS information
§3.2.7.3.3 Single program multiplexing
When user multiplex the single program, the multiplexing output channel of this program can be chose,
as shown below:
33
GOSPELL Digital Technology Co., Ltd
Fig.29 Program TS information
After the configuration, click “Submit” button at right-bottom of the page to save the setting.
§3.2.7.3.4 Batch program multiplexing
GM-2730S supports batch program multiplexing. It means multiplex all the programs of one channel to
another selected channel. As shown below:
34
GOSPELL Digital Technology Co., Ltd
Fig.30 Program TS information
Open the drop-down list box of “the output location of the batch select program” and select the channel,
click the “Submit” button, the multiplexing sets successfully as shown below:
Fig.31 Batch multiplexing
§3.2.7.3.5 Other functions
As shown in figure 25, “Keep Services When Failed”, “Default Charset” and “Analyze Timeout” are also
in this page:
Analyze timeout: when the search time is over the user setting, the search will stop.
Default char-set: detail in 3.2.6.1.1
Keep services when failed: when the search failure, switch on will delete all the information of current
page.
§3.2.7.4 Output service
As shown in figure 32, unfold “Output Service” to open the output program channel menu, shown as
below:
Fig.32 Output Channel Menu
Output program channel will list the type of output channel. As shown in figure 32, unfold “channel 01”
35
GOSPELL Digital Technology Co., Ltd
menu to check the number of channels, shown as below:
Fig.33 Output Channel List
Shown as figure 33, click a channel link, for example “TS001”, to enter the output TS program
information page, shown as below:
36
GOSPELL Digital Technology Co., Ltd
Fig.34 Output TS information page
§3.2.7.4.1 Output TS Information Monitoring and Configuration
Shown as figure 34, the output TS information page will display the TS related information, such as TS
ID, PAT version, PMT version, output programs, etc.
PSI/SI Information: users can manually configure the PSI/SI information of the output TS.
Remark: firstly, turn on the SDT switch to configure the SDT related settings.
Configurable parameters includes:
z TS ID
z PAT version, PAT sending interval
z SDT version, SDT sending interval
z TDT/TOT sending interval
【Remark】range of PAT version0 – 31.
§3.2.7.4.2 Program Information Edit
GM-2730S allows users to edit each individual program information. Click
program name to open the program information. As shown following:
button at the front of the
Fig.35 Program TS information
Editable information include program name, program number, PMT information, PCR PID, EIT
information, CA related information, ES information, etc.
z TS information
Users can type the program name, program number, and provider in the corresponding boxes, and click
“Submit” button to validate the setting.
z PMT information
Users can type the value of PMT PID, PMT version, sending interval in the corresponding boxes, and
37
GOSPELL Digital Technology Co., Ltd
click “Submit” button to validate the setting.
z PCR PID
Users can type the value of PCR PID in the corresponding box, and click “Submit” button to validate the
setting.
z EIT information
Users can turn ON/OFF the EIT time table tag, EIT previous/succeeding information tag, and click
“Submit” button to validate the setting.
z CA information
button in front of SCS CAS to open the CA information list.
Click
Users can type the value of CA PID in the corresponding box and turn ON/OFF the CA channel, then
click “Submit” button to validate the setting.
z PMT descriptor
To edit the PMT descriptors, click the “Edit”, then the “Descriptor Type” box at the bottom of the page will
display Service PMT Descriptors, shown as below:
The way to edit PMT descriptor is the same as the way to edit NIT descriptor, see section 3.2.6.4.1.
z SDT descriptor
To edit the SDT descriptors, click the “Edit”, then the “Descriptor Type” box at the bottom of the page will
display Service SDT Descriptors, shown as below:
The way to edit SDT descriptor is the same as the way to edit NIT descriptor, see section 3.2.6.4.1.
z ES information
Click
button in front of the TS to open the TS information list.
Users can type the value of ES PID in the corresponding box and turn ON/OFF the sending switch. To
38
GOSPELL Digital Technology Co., Ltd
edit ES descriptor, click “Edit” button, then the “Descriptor Type” box at the bottom of the page will
display Service ES Descriptors, shown as below:
Remark:
1.
PMT, SDT descriptors uses hexadecimal format.
2.
Please strictly comply with the DVB SI standard to edit the descriptors.
§3.2.7.4.3 Remove Service
To delete a service, check its corresponding service remove box, shown as below:
Fig.36 Delete Single Program
Click “Submit” button to delete the program. To delete all programs, check the “Service Remove Mark
Select All” box at the lower left corner, shown as below:
Fig.37 Remove All services
All service remove mark will be automatically checked, then click “Submit” button to delete all programs.
§3.2.7.5 Batch output services settings
Click the “batch output services setting” link to display the batch setting page, as shown
below:
39
GOSPELL Digital Technology Co., Ltd
The output service name and number could be modified by clicking of “submit”.
Remark: repetitive inspection to service No, are not allowed,
40
GOSPELL Digital Technology Co., Ltd
§3.2.8 Monitoring
Click “Monitor” button in the navigation bar to enter the monitoring page, shown as below:
Fig.38 Monitoring Page
§3.2.8.1 Alarms
Unfold “Alarms” menu to open the alarming information page, shown as below:
Fig.39 Alarms Menu
§3.2.8.1.1 Alarms Display
Click “Display” button, the alarm display page will be shown as below:
41
GOSPELL Digital Technology Co., Ltd
Fig.40 Alarm Information
Shown as figure 40, right column displays multiple alarm information. When there is no alarm, the status
light wll be
; when there is an alarm, the status light will turn to
, and the counter will start to count
the number of errors occurred.
The counter will not automatically restore to zero even the error is cleared. Users need to click the
“Reset” button to reset the counter to zero.
【Remark】the status light will stay red as long as the counter is not zero (though there may not be any
real-time errors).
§3.2.8.1.2 Alarm Setting
Click the “Setting” link to enter the alarm setting page, shown as below:
42
GOSPELL Digital Technology Co., Ltd
Fig.41 Alarm Setting page
As shown in figure 41, the left column is for the temperature alarm setting and the right column is for
other alarm information settings.
General Switch: choose between ON/OFF to enable/disenable the temperature alarms. Click
“Submit” to validate the setting.
Trap: when it is ON, GM-2730S will send the trap information to server through SNMP.
Panel: when it is ON, the alarm light on the front panel of GM-2730S will display the alarm.
Log Level: set level of severity for the alarm, from lowest to highest level: disable, info, warning,
critical. SNMP will judge the severity of the alarm depending its log level.
When finish the settings, click “Submit” button to validate them.
【Remark】The realization of Trap and log level is relate to the SNMP, for specific instructions, see the
SNMP user manual.
§3.2.8.2 Bitrate Monitor
Shown as figure 56, Unfold the “Bitrate Monitor” menu to select to monitor the input/output bit rate,
shown as below:
43
GOSPELL Digital Technology Co., Ltd
Fig.42 Bitrate Monitor Menu
§3.2.8.2.1 Input Channel Bit Rate
Shown as figure 42, Unfold the “Input Channel” menu, shown as following:
Fig.43 Input channel sub-menu
1、ASI input alarm
Click “channel 01 - ASI” link to enter the input channel bit rate monitoring page and set alarm information,
shown as below:
Fig.44 Input Channel Bit Rate Monitoring
Shown as figure 44, the left column displays the real-time bit rate of each channel; the right column
enable users to set the bit rate alarm setting, including lower limit, upper limit, and the enable switch.
Lower Limit: when the real-time bit rate is lower than this lower limit value, it will trigger an alarm.
Upper Limit: when the real-time bit rate is higher than this upper limit value, it will trigger an alarm.
Enable Switch: turn ON/OFF the alarm.
When finish the settings, click “Submit” button to validate them.
Shown as figure 43, unfold “channel 01 - ASI” menu, shown as below:
44
GOSPELL Digital Technology Co., Ltd
Fig.45 Channel sub-menu
Click “sub-channel 01” to enter the sub-channel Pid and bitrate information page, shown as following:
Fig.46 Channel sub-menu
2、IP input alarm
Click “channel 012- Ethernet” link to enter the input channel bit rate monitoring page and set alarm
information, shown as below:
45
GOSPELL Digital Technology Co., Ltd
§3.2.8.2.2 Output Channel Bit Rate
Shown as figure 47, Unfold the “Output Channel” menu, shown as following:
Fig.47 Output channel sub-menu
Click “channel 01 - Ethernet” to enter the output channel bit rate monitoring page, and set alarm
information, shown as below:
46
GOSPELL Digital Technology Co., Ltd
Fig.48 Output Channel Bit Rate Monitoring
Shown as figure 48, the left column displays the real-time bit rate of each channel; the right column
enable users to set the bit rate alarm setting, including lower limit, upper limit, and the enable switch
Lower Limit: when the real-time bit rate is lower than this lower limit value, it will trigger an alarm.
Upper Limit: when the real-time bit rate is higher than this upper limit value, it will trigger an alarm.
Enable Switch: turn ON/OFF the alarm.
When finish the settings, click “Submit” button to validate them.
Click “sub-channel 01” to enter the sub-channel Pid and bitrate information page, shown as following:
47
GOSPELL Digital Technology Co., Ltd
Fig.49 Output sub-channel Pid and bitrate monitor page
§3.2.8.2.3 System Bit Rate
Shown as figure 50, the lower right corner displays the system input, output, and insert bit rate, shown as
below:
Fig.50 System Bit Rate Monitoring
48
GOSPELL Digital Technology Co., Ltd
§3.3 Front Panel Operation of GM-2730S
Front panel LCD display of GM-2730S will show some initializing messages of the device at boot up
stage, such as but not limited to company logo, model number, etc. If there is an error during boot up,
then it will display the error message.
The front panel display will be locked if there is no key pressed within 60 seconds after device booting.
System configuration and menu browsing cannot be performed through the front panel keypad while it is
in LOCK status, and the LCD display will show current working status and alert messages (if available)
alternately.
User may unlock the LCD display by pressing "UP" and "DOWN" key continuously while it is locked, in
order to activate the front panel menu. After activating the menu, the LCD display will show the first
sub-menu of the main menu (VIEW ALARMS), as shown in the figure below:
Fig.51 Front Panel Menu
When entering operating menu, user may switch between different sub-menus by pressing “LEFT” and
“RIGHT” keys.
The front panel sub-menu items of GM-2730S are shown in the below table:
Menu ID
Function
Operating Description
1.0
Alarms
Display the system alarm information if
available.
Use “↑” and “↓” keys to switch between
alarms if there are more than one alarms.
2.0
Serial No.
Display serial number of the device
2.1
Software Version
Display software version information.
2.2
Hardware Version
Display hardware Version information.
2.3
Software Release
Date
Display software release date.
2.4
FPGA
Date
Display FPGA version information.
3.0
Local IP
Release
Set the management port IP address of
GM-2730S.
Press “ENTER” key to remove cursor.
49
Remarks
Read-only
The IP address should
be within the same
subnet
with
the
GOSPELL Digital Technology Co., Ltd
Use “←” and “→” keys to switching
between different digits of the IP address.
Press “ENTER” key to apply changes.
management
workstation.
Subnet Mask
Set the management port subnet mask of
GM-2730S.
Press “ENTER” key to remove cursor.
Use “←” and “→” keys to switching
between different digits of the subnet
mask.
Press “ENTER” key to apply changes.
3.2
Default Gateway
Set the management port gateway of
GM-2730S.
Press “ENTER” key to remove cursor.
Use “←” and “→” keys to switching
between different digits of the default
gateway.
Press “ENTER” key to apply changes.
3.3
MAC Address
Display the MAC address.
Read-only
Factory reset
Execute a factory reset.
Press “ENTER” key to enter the selection
mode.
Use “←” and “→” keys to select.
Select “OK” to reboot
the device.
Factory Defaults
Restore to factory defaults.
Press “ENTER” key to enter the selection
mode.
Use “←” and “→” keys to select.
Press “ENTER” key to apply changes.
Select “OK” to reboot
the device.
Language
Set the menu language on front panel.
Press “ENTER” key to enter the selection
mode.
Use “←” and “→” keys to select.
Press “ENTER” key to apply changes.
Support
Chinese/English menu.
3.1
4.0
4.1
5.0
Default
255.255.255.0
is
After complete menu operation, user may lock the front panel LCD display and keypad by
Pressing “MENU” and “ENTER” key continuously.
50
GOSPELL Digital Technology Co., Ltd
Annex A: Technical Specifications
A.1 Common Technical Specifications
Properties
Characteristic
Specifications
AC Input Voltage
100~240VAC
Power Supply &
AC Input Frequency
50~60Hz
Consumption
Power Consumption
35W
No. of Power Supply Modules
1
Operating Temperature
5°C ~40°C (41°F ~104°F)
Storage Temperature
-25°C ~70°C (-13°F~158°F)
Air Pressure
86~106KPa
Humidity
10%~90%
Operating/Storage
Environment
A.2 Interfaces
Characteristic
Data Input
Interface
Management
Port
Data
input/outputs
Properties
Specification
BNC-FEMALE
RJ45
Quantity
8
Impedance
75Ω
MAC
IEEE 802.3 1000BASET self-adaptive
Connector
RJ45
Physical bandwidth
100Mbps
Maximum transmission distance
100M
Cable requirement
Cat5e or Cat 6
MAC
IEEE 802.3 1000BASET self-adaptive
Connector
RJ45
Quantity
1
Physical bandwidth
1250Mbps
Maximum transmission distance
100M
Cable requirement
Cat5e or Cat 6
A.3 Multiplexing Specifications
Characteristic
TS input
TS output
Properties
Specification
Input TS number
0~128
Total services number(total)
0~512
Service number per input TS
Output TS number
Total services number(total)
0~64
0~450
0~512
51
GOSPELL Digital Technology Co., Ltd
Service number per output TS
0~64
ISO/IEC 13818-1
Standard(syntax and send period)
DVB SI(ESI EN300468)
PSI for output TS
PAT/PMT: Generated automatically
Table type
TDT/TOT: Optional
A.4 Input / Output Performance
Characteristic
ASI Input
IP Input
IP Output
Properties
Specification
Quantity
0~8
Maximum bit rate per channel
≤100Mbps
Quantity
Total bit rate
Quantity
Total bit rate
0`~120
≤800Mbps
0`~450
≤800Mbps
52
GOSPELL Digital Technology Co., Ltd
Annex B: Frequently Asked Questions
Symptoms
Possible Causes
The power supply cable is not
plugged in
No display at boot up
The error message “ cannot find
server” appears on the screen
when access equipment by a
web browser
Fail to scan any input programs
Fail to scan programs in specific
input
Succeeding device
receive any program
fails
to
Succeeding device fails to
receive data in specific output.
Network connect error
IP address mismatch
Subnet mismatch, i.e., manage
port of GM-2730S and computer
locate in different subnet
Improper connection of BNC cable
at data input.
Source device is not working
properly
Improper connection of output
cable
Error IP address of succeeding
device
The succeeding device is not
working properly.
Serious mis-decoding occurs in
all programs.
Program data overflow.
Serious mis-decoding occurs in
specific program.
Preceding device of this program is
not working properly.
- 53 -
Recommended Resolution
Plug in the power supply cable
Check if the manage computer and the
manage port of GM-2730S has been
connected to a same network
Input correct IP address in URL bar
Modify the manage port IP of GM-2730S
by front panel operations.
Check if the cable is properly connected.
Check malfunction in the source device
Connect the output cable properly.
Check the IP address of succeeding device
Check malfunction in the succeeding
device(e.g. DVB-C receiver)
Reduce number of programs or streams in
order to maintain the total output bit rate
under the total modulated output bit rate.
Check the configuration errors and
malfunction in the preceding device.
Postscript
Thank you for purchasing products of GOSPELL Digital Technology Co., Ltd!
GOSPELL Digital Technology Co., Ltd and Chengdu TONCY Digital System Co., Ltd fully own the
intelligent property rights of this product. Our company reserves the rights to pursue legal actions against
unauthorized duplication and usage of the product and its software by any organizations or individuals.
For ensuring long-term stability of product operation, please strictly follow the methods, procedures and
constraints introduced by this manual while operating the device.
After purchasing of our devices, please leave your contact details to our customer service staff. We will
track the usage of the device randomly, and inform you while there is a new version of software available
for your device upgrading.
When encountering malfunction of the device, please contact our customer service staff in time for
maintenance and repairing.
GOSPELL Digital Technology Co., Ltd
Address: F10-F12 Idea Land, F518 Baoyuan Road, Baoan Central Distinct, Shenzhen, China
Technical Support Tel: +86-755-26715680
Fax: +86-755-26716142
Technical Support Email: [email protected]
Website: www.gospell.com