Download MFB for Modicon M340 using Unity Pro
Transcript
Maintenance Replacing a Faulty Servodrive At a Glance If the servodrive fails, it may be necessary to swap it for an identical servodrive (reference). To do this, you are advised to save the adjustment parameters to a data table using the TE_UPLOADDRIVEPARAMETER (see Unity Pro, Motion Function Blocks, Block Library) block. The TE_DOWNLOADDRIVEPARAM (see page 60) block then allows you to restore the saved data to a new servodrive. Data Backup The table below describes the procedure used to back up the servodrive’s data using the TE_UPLOADDRIVEPARAMETER (see Unity Pro, Motion Function Blocks, Block Library) block: Step 76 Action 1 Disable the Enable parameter, which belongs to the MC_POWER (see Unity Pro, Motion Function Blocks, Block Library) block. Result: the servodrive switches to Disable (see Unity Pro, Motion Function Blocks, Block Library) mode. 2 Enable the input parameter Execute. Result: the servodrive switches to Downloading (see Unity Pro, Motion Function Blocks, Block Library) mode. The data table assigned to the output parameter PARAMETERSET is filled in. Note: Please back up data to a .DAT file using PLC →Transfer PLC data to the file if the PLC has no memory card. 35013563 05/2010