Download AUDIO PRECISION System One Users
Transcript
ERROR MESSAGES 1 : Select or use only DSP programs supplied by Audio Precision with the .DSP extension. To date all DSP programs released are compatible with the 2.10A release of S1.EXE. 33-17 CORRECTIONS : Select generator amplitude (GENAMP) as a sweep SOURCE-2 parameter only. GENFREQ may only be a sweep source-2 selection 2 : Select the appropriate version DSP programs to be run with the selected S1.EXE software or visaversa. NOTE : Error generated by the FFTGEN DSP program. NOTE : Refer to the technical bulletins issued with each update. CAUSES : Caused by trying to select GENFREQ as sweep SOURCE-1. FILE WRITE ACCESS DENIED — DIRECTORY FULL OR WRITE PROTECTED CORRECTIONS : Select generator frequency (GENFREQ) as a sweep SOURCE-2 parameter only. CAUSES : The selected file cannot be written to a storage medium because the file attribute is set to READ ONLY, the storage medium does not have room to store the file, or the disk is write protected. Generator waveform frequencies too close for triggering or frequency correction CORRECTIONS : Clear the READ ONLY file attribute using the DOS ATTRIB command, create room for the desired file, or remove the write protection from the storage medium. NOTE : Error generated by the FASTTRIG DSP program. CAUSES : An attempt to execute a test with a DSP generator waveform loaded that has tones that violate the minimum frequency spacing of six bins (about 35 Hz with maximum resolution signal). FREQRS may only be a sweep source-2 selection CORRECTIONS : NOTE : Error generated by the FASTTEST and FASTTRIG DSP programs. CAUSES : Attempting to select the frequency resolution (FREQRS) as a sweep SOURCE-1 stimulus. CORRECTIONS : Select frequency resolution (FREQRS) as a sweep SOURCE-2 parameter only. G GENAMP may only be a sweep source-2 selection NOTE : Error generated by the FFTGEN, MLS, FASTTEST and FASTTRIG DSP programs. CAUSES : Attempting to set the generator amplitude (GENAMP) parameter as the sweep SOURCE1 selection on the sweep definitions panel. 1 : Change to a waveform which conforms to the minimum spacing criteria. 2 : Disable generator waveform & frequency correction warnings by setting the MEASURE right hand field to OFF on the FASTTRIG DSP panel. GOTO CANNOT FIND TARGET LABEL CAUSES : The procedure currently being run can’t find the label designated by the GOTO command. CORRECTIONS : Check to see that the label exists in the same procedure as the GOTO statement and that the characters in the label are the same as designated by the GOTO statement. H