Transcript
Overview and Specifications 1-1-1-1. Example1: Application to detect objects with void space (hole) When an object has a void space (small size) and moves at a constant speed Chapter (Example of Off-Delay function) Muting with Single Beam Sensor 䠄Conventional䠅 Muting with F3W-MA Safety Light Curtain Safety Light Curtain 1 System Overview Void Space F3W-MA Single Beam Sensor A B Stable detection is not possible due to void space B A A B B A Off-Delay function ignores impact of void space Muting Input A Muting Input A Muting Input B Muting Input B Muting State Muting State Muting State: Stopped Muting State: Maintained When an object has a void space (small size) and moves at a very slow speed (Example of Void Space Prevention function) Muting with Single Beam Sensor (Conventional) Muting with F3W-MA Very slow speed Void Space Prevention function helps the stable detection by multi-axis detection Off-Delay function can not fit this application due to very slow speed 1-1-1-2. Example2: Application where an object temporarily stops and moves back and forth (Example for Chattering Prevention function) Muting with Single Beam Sensor 䠄Conventional䠅 㻭 㻮 F3W-MA User’s Manual 㻮 㻭 㻭 Stable detection is not possible due to vibration if object suddenly stops at the position of muting sensor Chattering Prevention function helps the stable detection Muting Input A Muting Input A Muting Input B Muting Input B Muting State Muting State BMuting State: Stopped 2 Muting with F3W-MA Muting State: Maintained 㻮 㻮 㻭