Download ATOM1 : MPC860 ATM Microcode User`s Manual

Transcript
Initial Entry
Point
HUNT
4 Byte by 4 Byte
Search for
Correct HEC
Alpha (7)
Consecutive
Incorrect HECs
Restart
Reception
Command
Single Correct
HEC
Single
Incorrect
HEC
SYNCH
Cell by Cell
Verification of
HECs
PRESYNC
Restart
Reception
Command
Cell by Cell
Search for
Correct HECs
Delta (6) Consecutive
Correct HECs
Figure 18. Cell Delineation State Diagram
I.432 specifies that the hunt state searches for a correct HEC on a bit-by-bit basis but ATOM1
uses a word by word search. For G.804 framing of ATM cells, the HEC field is always aligned
with the E1 or T1 frame octet timeslots so bit-by-bit searching is not required. To ease
implementation, this was taken a stage further and ATOM1 uses a word by word search. Over
the course of four cells received (212 bytes) with correct HECs, there will be one matching and
aligned HEC. This is the point where the state machine jumps to the presync state.
In the presync state, ATOM1 has detected cell boundaries and is verifying that they are correct.
ATOM1 leaves the presync state after a single cell with an incorrect HEC is received or the
Restart Reception command is given. When six consecutive cells with valid HECs are received,
ATOM1 jumps to the sync state and begins reception. The state machine advances immediately
after reception of the sixth correct HEC and is not delayed until the end of the cell. This means
that five cells with valid HECs are discarded and the sixth is received into a data buffer.
In the synch state, ATOM1 receives data and control cells and discards incoming empty cells.
When a stream of cells with incorrect HECs are received, the first six consecutive cells are
received and on reception of the seventh incorrect HEC, ATOM1 immediately jumps to the
hunt state and does nor receive the cell with the seventh incorrect HEC. ATOM1 also jumps to
the hunt state after the Restart Reception command.
When cell payload scrambling is enabled, the descrambler will self-synchronise with the
incoming data after 43 bits. Hence, after starting the receiver, the descrambler will attain
synchronisation during reception of the first cell in the presync state.
MPC860 ATOM1 User’s Manual 1.0
-35-
No Restriction on Circulation