Quantum and Evolution Series Installation and Operating Handbook 1.19.3.1.3 Edit-Tx-Clocks Screen Tx-path clock source: [Tx Clock In] New: Receive reference Options: Tx Clock In The external clock supplied on the interface Clock In line will be used. Should this clock fail then the modem will switch to an internal backup clock. Internal The modem outputs a clock on the Int Tx Clock Out line for use by external equipment. The clock is normally generated from the internal frequency reference. Alternatively, a station clock of 10MHz can be applied to the unit and used to synchronise all internal clocks and IF synthesisers which normally use the internal reference. Receive reference The Tx clock is generated from the Rx output clock. This is only of any practical use when the Rx clock is set to Satellite or Station clock. Station The Tx clock is generated from the station clock. Hub Factory default: Description: Internal Sets the clock source for the Tx path. 7-23