Download User`s Manual - Rorke Data

Transcript
Rorke Data
Error Message
Reason/s For The Error
Things You Can Do
Array # LUN #: [old status] => Initialization
Required
• The specified LUN is newly
created and waiting to be
initialized as there is still a
pending LU under initialization.
• No action required.
Array # LUN #: [old status] => LUN Failed
• The specified LU had not
been configured successfully.
• Delete and Initialize the LU
once again.
Disk #: [old status] => Failed
• The specified disk drive has
failed.
• Replace the disk drive with a
new disk drive for it to start
reconstruction.
Disk #: [old status] => Offline
• Specified disk drive was
assigned as offline, or the array
the drive belongs to was
removed.
• No action required.
Disk #: [old status] => Missing
• The disk drive was removed.
• Insert the disk into the drive
to start reconstruction.
Disk #: [old status] => Reconstruction Mode
• Specified disk drive is under
reconstruction.
• No action required.
Disk #: [old status] => Retry Mode
• Specific disk drive under
retry mode.
• No action required.
Disk [disk #]: [old status] => Blank
• Offline disk was removed.
• No action required.
Power Supply #: [old status] => Failed
• Power supply has failed.
• Replace power supply.
Power Supply #: [old status] => Missing
• Power supply is not found.
• Insert power supply.
Fan #: [old status] => Failed
• Fan module has failed.
• Replace fan module.
Fan #: [old status] => Missing
• Fan module is not found.
• Insert fan module.
Primary Controller: [old status] => Failed
• Primary controller has
failed.
• Replace primary controller
card.
Primary Controller: [old status] => Missing
• Primary controller is not
found.
• Insert primary controller
card.
Secondary Controller: [old status] => Failed
• Secondary controller has
failed.
• Replace secondary
controller card.
Secondary Controller: [old status] => Missing
• Secondary controller is not
found.
• Insert secondary controller
card.
Battery Backup Unit #: [old status] => Failed
• Battery module has failed.
• Replace battery module.
Battery Backup Unit #: [old status] => Missing
• Battery module is not found.
• Insert battery module.
Battery Backup Unit #: [old status] => Insufficient
• Battery module is running
low.
• Replace/Calibrate battery
module.
7.5
States of Components/Features
The following are tables for the possible states that the Galaxy HDi components/features may
have. When these states occur, they are included on the messages for E-mail notification and/or
SNMP traps.
158