Rorke Data Error Message Reason/s For The Error Things You Can Do Array # LUN #: [old status] => Initialization Required • The specified LUN is newly created and waiting to be initialized as there is still a pending LU under initialization. • No action required. Array # LUN #: [old status] => LUN Failed • The specified LU had not been configured successfully. • Delete and Initialize the LU once again. Disk #: [old status] => Failed • The specified disk drive has failed. • Replace the disk drive with a new disk drive for it to start reconstruction. Disk #: [old status] => Offline • Specified disk drive was assigned as offline, or the array the drive belongs to was removed. • No action required. Disk #: [old status] => Missing • The disk drive was removed. • Insert the disk into the drive to start reconstruction. Disk #: [old status] => Reconstruction Mode • Specified disk drive is under reconstruction. • No action required. Disk #: [old status] => Retry Mode • Specific disk drive under retry mode. • No action required. Disk [disk #]: [old status] => Blank • Offline disk was removed. • No action required. Power Supply #: [old status] => Failed • Power supply has failed. • Replace power supply. Power Supply #: [old status] => Missing • Power supply is not found. • Insert power supply. Fan #: [old status] => Failed • Fan module has failed. • Replace fan module. Fan #: [old status] => Missing • Fan module is not found. • Insert fan module. Primary Controller: [old status] => Failed • Primary controller has failed. • Replace primary controller card. Primary Controller: [old status] => Missing • Primary controller is not found. • Insert primary controller card. Secondary Controller: [old status] => Failed • Secondary controller has failed. • Replace secondary controller card. Secondary Controller: [old status] => Missing • Secondary controller is not found. • Insert secondary controller card. Battery Backup Unit #: [old status] => Failed • Battery module has failed. • Replace battery module. Battery Backup Unit #: [old status] => Missing • Battery module is not found. • Insert battery module. Battery Backup Unit #: [old status] => Insufficient • Battery module is running low. • Replace/Calibrate battery module. 7.5 States of Components/Features The following are tables for the possible states that the Galaxy HDi components/features may have. When these states occur, they are included on the messages for E-mail notification and/or SNMP traps. 158