Download 5.1 Programming the SMCS116SpW
Transcript
Astrium GmbH Doc No: SMCS_ASTD_UM_116 Rev.: 1.2 Date: 16.06.2008 Page: 136 of 157 SMCS116SpW User Manual 12.21 Test Port (JTAG) Description Symbol Min. Max. (5 V) (5 V) Min. Max. Unit (3.3 V) (3.3 V) TCK period tTCK 100 100 ns TCK width high tTCKH 40 40 ns TCK width low tTCKL 40 40 ns TMS, TDI setup before TCK high tTIS 8 15 ns TMS, TDI hold after TCK high tTIH 8 8 ns TDO delay after TCK low tTDO SMCS Inputs setup before TCK high tSYSS 8 8 ns SMCS Inputs hold after TCK high tSYSM 8 8 ns SMCS Outputs delay after TCK low tSYSO 18 23 27 – All Rights Reserved – Copyright per DIN 34 – 43 ns ns