Transcript
2 General Specifications Performance (Accuracy) (The specifications are expressed with simulated inputs.) Basic pH Linearity Repeatability Accuracy :± 0.01 pH : ±0.01 pH : ±0.01 pH ORP Linearity Repeatability Accuracy :± 1 mV : ±1 mV : ±1 mV Measurement Parameter The FLXA21® can be configured to measure: • pH/Oxidation-reduction Potential (pH/ORP) • Contacting Conductivity (SC) • Inductive Conductivity (ISC) • Dissolved Oxygen (DO) Note: T he available measurement parameter depends on a sensor module installed in the analyzer. Analyzer Structure Module structure Composition of Analyzer One (1) Base module General Purpose • CSA, FM, ATEX, (pending) • FOUNDATION Fieldbus, (pending) • PROFIBUS (pending) One (1) or two (2) Sensor modules inputs The FLXA21® supports up to two sensors of the same type, thereby reducing installation costs. Allowable combinations when two modules are installed are: • pH/ORP and pH/ORP • SC and SC • DO and DO pH/Redox Potential (pH/ORP) Input Specification Dual high impedance input (≥1012 Ω), compatible with all Yokogawa pH/ORP sensors and most competitor electrodes. Temperature: Pt1000 Pt100 6k8 PTC10k NTC 8k55 3k Balco PTC500 with Pt100 Linearity Repeatability Accuracy Calibration Semi-automatic 1 or 2 point calibration using pre configured NIST, US, DIN buffer tables 4, 7 & 9, or with user defined buffer tables, with automatic stability check; or Manual adjustment to grab sample. Input Range Conductivity : - 2 to 16 pH : -1500 to 1500 mV : 0 to 100 rH : : : : : : : -30 -30 -30 -30 -10 -30 -30 to to to to to to to 140 140 140 140 120 140 140 °C °C °C °C °C °C °C (-22 (-22 (-22 (-22 (-22 (-22 (-22 Input Specification Two or four electrode measurement with square wave excitation. Any cell constant from 0.005 to 50.0 cm-1 can be used. Influence of cable can be adjusted by doing an AIR CAL with the cable connected to a dry cell. to to to to to to to 284°F) 284°F) 284°F) 284°F) 284°F) 284°F) 284°F) Resistivity Temperature: Pt1000 Pt100 Ni100 NTC 8k55 Pb36(JIS NTC 6k) Cable length Cable length Output Range pH ORP rH Temperature :± 0.4 ºC : ±0.1 ºC : ±0.4 ºC Conductivity (SC) Measurement Input Range pH ORP rH Temperature (with Pt1000, 6k8, PTC10k, NTC 8k55, 3k Balco, PTC500) Linearity : ±0.3 ºC Repeatability : ±0.1 ºC Accuracy : ±0.3 ºC :6 0 meters (196 feet) from the sensor to the analyzer : : : : : : : : GS 12A01A02-01E-E min. Span 1 pH max. Span 20 pH min. Span 100 mV max. Span 3000 mV min. Span 2 rH max. Span 100 rH min. Span 25 ºC max. Span 200 ºC (for 8.55kV NTC sensor max. 120 ºC) Output Range Conductivity Resistivity Temperature :m in. 0 µS/cm : max. 200 mS x Cell constant (over range 2000 mS/cm) : min. 0.005 kΩ / Cell constant : max. 1000 MΩ x cm : : : : : - 20 -20 -20 -10 -20 to to to to to 250 200 200 120 120 ºC ºC ºC ºC ºC (-4 to 482°F) (-4 to 392°F) (-4 to 392°F) (14 to 248°F) (-4 to 248°F) :6 0 meters (196 feet) from the sensor to the analyzer. Influence of cable can be adjusted by doing an AIR CAL with the cable connected to a dry cell. :m in. 0.01 µS/cm : max. 2000 mS/cm (max 90% zero suppression) : min. 0.001 kΩ x cm : max. 1000 MΩ x cm (max 90% zero suppression) : min. 25 ºC (77°F) : max. 200 ºC (392°F) (for NTC 8k55 sensor max. 120 ºC (248°F))