Download Positioning ACU
Transcript
3.5.1.3 No motor encoder, external encoder for positioning In some applications the speed control accuracy and the dynamic behaviour of a sensorless motor control are sufficient. Positioning is possible in non-slip and in slipcontaining systems via an external encoder. Configuration 30 = 440, only position encoder Encoder 1 Encoder 2 Motorregler Position controller Operation mode Operation mode 490 493 Actual Speed Source 766 = 3 - Actual Position Source 1141 = Machine Model Division Marks Division Marks 491 494 "1 - Speed Sensor 1" or "2 - Speed Sensor 2", depending on the application Level 495 Set the encoder behaviour in the correlative parameters for speed sensor 1 and speed sensor 2. The speed sensor 1 parameters are only available if an expansion module with speed sensor input is installed. 3.5.1.4 Consider the operation mode settings for speed sensor input The digital input signals S4IND, S5IND and S6IND can set as signal sources in all configurations (parameter Configuration 30). − In parameter settings Operation Mode 490 > 0 the inputs S4IND and S5IND are evaluated only as speed sensor inputs. Other functions at these inputs are not evaluated. − In parameter settings Operation Mode 490 > 1000 additional the input S6IND is evaluated as speed sensor track. Other functions at this input are not evaluated. Digital inputs S4IND S5IND S6IND 20 Operation Mode 490 = 1001 … 1132 1 … 1000 0 Speed sensor 1 track B Free programmable Speed sensor 1 track A Free programmable Speed sensor 1 track Z Home switch Application manual Positioning 04/08