Download Positioning ACU
Transcript
6.3 Status word 411 Parameter Status word 411 includes two specific bits of the positioning. These bits can be evaluated by the logic control. Note: The applicable status word is dependent on the operation mode Local/Remote 412. The status word is used in most of the operation modes for parameter Local/Remote 412. If the inverter is controlled via statemachine (Local/Remote 412 = „1 Control via Statemachine“) a different status word is applicable. Refer to the operating instructions of the communication modules or expansion modules. Statusword 411 Bit-No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 8 14 Function Ready for being switched on Switched on Operation – released Error Voltage – disabled Quick Stop Starting lock-out Warning Homing Done Remote Reference value reached Limit value reached Target Position Reached Warning 2 Homing Done. Homing is carried out successfully. The home position is set. This bit stays set until homing is restarted. The bit is only output in the settings of parameter Local/Remote 412 ≠ “1 - Control via Statemachine”. Target Position Reached. Target Position/Distance 1202 of a positioning operation was reached, and current actual position is within the range set in parameter Target window 1165 for a minimum period of Target window time 1166. The bit is only output in the settings of parameter Local/Remote 412 ≠ “1 - Control via Statemachine”. The bit is reset if: − The drive travels out of the range set in parameter Target window 1165 or − JOG-Mode is enabled or − Homing is started or − Operation mode “Teach-In” is enabled 154 Application manual Positioning 04/08