CAUTION
A step-down transformer is optional on some
machine models. Be certain to verify transformer
Kva rating (where applicable), as well as local
electrical code requirements before sizing and
installing the incoming power wiring. End user must
use a step-down transformer where factory electrical
power varies more than ± 10% of machine's
nameplate voltage.
All wiring is to be preformed by a competent,
licensed electrician.
Note: Step-down or voltage regulating transformers
are external (peripheral) to machine tool and are
considered primary input line (source) for machine.
Local electrical code or practice may require a circuit
breaker or other switching device for isolation of
electrical power when this type of transformer is
used. In such cases, machine tool end user is required
to supply necessary circuit breaker or switching device.
FAILURE TO COMPLY CAN RESULT IN
PERSONAL INJURY AND/OR DAMAGE TO
MACHINE.
ELECTRICAL CONNECTIONS
All wiring is to be performed by a competent, Licensed
Electrician in accordance with all local, state, and
federal codes and regulations; along with any special
information provided on machine nameplate or
electrical specification plate.
1. Verify supply voltage is same as voltage listed
on ELECTRICAL SPECIFICATION PLATE located
on side of Electrical Enclosure.
FIGURE 1-4, Back of Electrical Enclosure
GAGE
CAUTION
Doors are equipped with lockable Safety Door
Latches. Doors should be closed and latched during
operation to prevent accidental interruption of
operation from doors being opened. Doors Latches
should be Locked-Out and Tagged during servicing
to prevent machine from being powered up.
CANISTERS
2. If applicable: Loosen Safety Latches on door(s) to
enclosure, using a screwdriver. Or, on CE models,
unlock doors to Electrical Control Enclosure using
key supplied with machine. Door(s) to enclosure is
equipped with Key-Lock Safety Latches.
FIGURE 1-5, Filter Canister
WARNING
Residual Voltage exists for 2-3 minutes after
Master ON/OFF Switch is turned OFF. Before
working inside Enclosure, wait for all fans to stop
running to allow drives to discharge.
LATCH
3. Turn Master ON/OFF Switch to OFF position and
open Doors (see Figure 1-4). (Doors WILL NOT open
unless Master ON/OFF Switch is in OFF position.)
WARNING
You must use hole provided. Drilling any new holes in
electrical enclosure may void machine warranty.
FIGURE 1-6, Coolant Reservoir
2