Download Manual - Festo
Transcript
A. Technical appendix Power supply for bus interface/internal electronics Pins 2, 3; bus interface – Rated value – Tolerance – Current consumption (at 24 V) External fuse required 24 V DC (not protected against incorrect polarity) 11.5...25 V 50 mA Residual ripple 4 Vpp (within tolerance) Bridging time during logic voltage failure 20 ms Electromagnetic compatibility – Interference emission – Immunity to interference *) Tested as per EN 55011 Limit value class A*) Tested as per EN 50082-2 The CPV valve terminal with direct connection for DeviceNet type CPV..-GE-DN-8 may also be used with individual authorization in residential areas (living, business and commercial areas, small firms). Technical specifications for the pneumatic components can be found in the “Pneumatics manual, P.BE-CPV-...”. A-4 Festo P.BE-CP-DN-EN en 0009a