Figure 77. Doors Form
Fields and controls
The following is a list of fields that may require additional information for you to complete. Because forms are
user customizable some of these fields may not appear, or may appear in a different order than that shown in
the following table. There is no required sequence to follow.
Table 80. Doors form fields
Field name
Description
Door Values
Define the door and the times allowed before alarms are enabled.
Description
Type a door description up to 60 alphanumeric characters long.
Unlock Time
(secs)
Enter the number of seconds that this door may remain unlocked due to a valid badge read or an exit button
being pushed. This field controls how long the door strike is unlocked for the badge holder to open the door.
After that, the Allowable Open Time controls how long the badge holder may keep the door open while the
badge holder is passing through.
Forced Open
Shunt Time
(secs)
Enter the number of seconds that the Door Forced Open alarm will be shunted before an alarm is generated.
When the shunt time expires, the Door Forced Open alarm is enabled.
Allowable
Open Time
(secs)
Enter the number of seconds that this door may be open (due to a valid badge read) before an alarm condition
exists. Be sure to set the Held Open Sensing button to Detected (in the Door Control box) to activate this
feature.
The number of seconds set here must be greater than the Unlock Time. This field controls how long a door
strike will remain unlocked after the Unlock Time expires so a badge holder can open the door and not get a
Door Forced Open alarm.