Download "user manual"
Transcript
IM2830AJ.DOC IM2830A Directory: 962830A Shadin Avionics INSTALLATION MANUAL FUEL/AIR DATA COMPUTER P/N 962830A-1(A), 962830A-2(A), 962830A-3(A) Rev: J Page: 9-20 Stage 3 Loop-back configuration: Switch 1 is set to 3 to indicate that the stage 3 loop-back is being performed. SWITCH 2, K-FACTOR TABLE SELECTION: For F/ADC 962830-1(A) and 962830-2(A) only. 0 1 2-F - Standard K-FACTOR Matrix 0 - (Table 2 in this manual) Alternate K-FACTOR Matrix 1- (Table 3 in this manual) (DO NOT USE) SWITCH 3, FUEL FLOW DELAY TIME 0 - No Delay 1 - 5 Second Delay 2 - 10 Second Delay 3 - 15 Second Delay 4 - 20 Second Delay 5 - 25 Second Delay 6 - 30 Second Delay 7 - 35 Second Delay 8 - 40 Second Delay 9 - 45 Second Delay A-F - (DO NOT USE) SWITCH 4 0 1 2-F SPECIAL OPTION DESCRIPTION -ARINC 429 labels 206 (IAS) and 210 (TAS) are not transmitted if the IAS < 20 knots -ARINC 429 labels 206 (IAS) and 210 (TAS) are transmitted as zero knots if the IAS < 20 knots Reserved – DO NOT USE F/ADC Software Version 93.00.67 and up 93.00.67 and up