Download USER MANUAL
Transcript
Operating the PL-18 Control Port Expander 6 Operating the PL-18 Control Port Expander The PL-18 is typically used to expand the number of ports available to an RC series remote control device. The combined RC 1 and PL-18 are configured from the RC device using RC-SV software that can be downloaded from the Kramer Web site 2. The PL-18 can also be operated directly from a PC, touch screen system, or other serial controller using the serial commands of Kramer’s Protocol 3000. For an explanation of all control commands, see section 9. In addition to operating the PL-18, machine software can be upgraded, and device parameters can be accessed and changed using P3K Wizard software also available from the Kramer Web site2 (see section 10). 7 Technical Specifications The PL-18 technical specifications are shown in Table 2: Table 2: PL-18 Control Port Expander Technical Specifications PORTS: OUTPUTS: LED INDICATORS: POWER SOURCE: DIMENSIONS WEIGHT: ACCESSORIES: OPTIONS: 3 2 bi-directional RS-232 ports on terminal block connectors; 1 USB 4 relays on terminal block connectors, 36V AC or DC, 1A, 60V AC max on noninductive load; 2 IR outputs on 3.5mm mini jack connector ON (green), RS-232 (Tx - red and Rx - green), IR (green), relays (green) 5V DC, 260mA 12cm x 7.6cm x 2.4cm (4.72" x 2.97"x 0.96") W, D, H 0.6kg (1.4lbs) Power supply 5V DC 15 meter and 20 meter IR emitter extension cables 1 When configuring an RC-2 to work with the PL-18, the RC-SV software version must be at 2.1.2.32 or higher and the RC-2 firmware version must be at 1573 or higher 2 At www.kramerelectronics.com 3 Specifications are subject to change without notice 6 KRAMER: SIMPLE CREATIVE TECHNOLOGY