Download User`s Manual

Transcript
AT-140GE
TriggerMode Off:
While AcquisitionActive is effective, self
running operation takes place.
 ExposureEnd trigger:When ExposureMode is set at TriggerControlled, this
controls the stop timing only when ExposureStart is ON.
TriggerMode On:
While AcquisitionActive is effective, ExposureMode is
TriggerControlled and ExposureStart is ON, the exposure
is stopped by using the signal selected by ExposureEnd as
the trigger and the data is output.
TriggerMode Off:
While AcquisitionActive is effective, self
running operation takes place.
9.2.2 Memory readout control
It is possible to control the readout timing after the signal from the CCD is stored in
the Frame Memory.
 JAI_AcquisitionTransferStart:This activates the memory readout control.
TriggerMode ON :
TriggerMode OFF :
While AcquisitionActive is effective,
AcquisitionTransferStart outputs the stored data.
While AcquisitionActive is effective, the stream is
output.
9.2.3 Triggersoftware
This is one of the trigger sources and is the software trigger command.
This has one command signal to each of the 6 items of TriggerSelector.
To use this function, TriggerSource must be set at TriggerSoftware.
9.2.4 Triggersource
The following signals can be selected as the trigger signal source.
① Off
② Software
③ Line 1(TTL out1)
④ Line 2(TTL out2)
⑤ Line 3(Opt out1)
⑥ Line 4(Opt out2)
⑦ Line 5(Opt in1)
⑧ Line 6(Opt in2)
⑨ Line 7(TTL in1)
⑩ Line 8(LVDS in)
⑪ Timer1Start
⑫ Timer1End
⑬ Counter1Start
⑭ Counter1End
⑮ UserOut1
⑯ UserOut2
⑰ UserOut3
- 42 -