Download USO RESTRITO
Transcript
USO RESTRITO 1 Barco Vivaldi Set the RS485/RS422 Vivaldi II port to MPK protocol and the address to match that show in TallyMan for the quad-split display. The port must be configured as 1 x 4. The address field at the bottom of the list of four fields in the Vivaldi set-up is the one that must match TallyMan first address for that particular Vivaldi’s address - decimal or hex. All other ports must be set to a different protocol, and are not used. Remote 1 Socket TM1 / TM2 RS-232 VIVALDI RS-232 D9 Socket 2 3 D9 Plug → RX → 8 ← TX ← 7 5 GND 6 RS 422 Cable Connections TM1 / TM2 VIVALDI RCDS BUS D9M Control Port (D9 Plug) (D9 plug) 3 ← 4 8 ← 2 7 → 5 2 → 3 6,4 GND 7 TM1 / TM2 RS 422 Control Port Details CONTROL RS 422 / RS485 CONNECTORS D9 SOCKETS 1 0v 6 0v 2 TX- 7 TX+ 3 RX+ 8 RX- 4 0v 9 0v 5 - Communication Parameters • • • • • 38K4 baud 8 data bits Even parity 1 start bit 2 stop bits Multiviewers V8 6