Calibrating a Data Source Calibrating the displayed data is possible for many of the Data Sources. Press and hold the & and " keys for ten seconds to enter the Calibration Editor (until you hear a long beep). The data source value, display identifier (1, 2, 3, L or r) and the word “CAL” will be displayed as shown in Figure 22. Quick press the & key to select the desired display identifier (1, 2, 3, L or r). Press and hold the % and $ keys to change the calibration value. Press the & key for 1 second (until the long beep) to accept the new value, save it to memory and leave the Calibration Editor mode. Figure 24 - Calibration Editor Editing the calibration for the Data Source shown on digital display #2 When calibrating the Time-Of-Day clock a Clock Calibration value between 0 and 100 (nominal value is 50 ) will be shown on Display #1 and the time of day shown on Display #3. Increase the Clock Calibration value to speed up the clock, decrease the Clock Calibration value to slow down the clock. Increasing the Clock Calibration value by one will increase the clock speed by 1 second per day. Decreasing the Clock Calibration value by one will decrease the clock speed by 1 second per day. Page 23