Download Applikon bioconsole ADI1035 manual NL
Transcript
GEBRUIKSAANWIJZING ADI 1035 Bio Console Versie 3, oktober 1996 BIO CONSOLE ADI 1035 GEBRUIKSAANWIJZING 1. Basis Bio Console 2. Gastoevoer 3. Temperatuurregeling 4. Roersnelheidsregel ing 5. Niveauregeling 6. Pompen 7. Schakelaarstanden 8. Tekeningen appiiKorf DEPENDABLE INSTRUMENTS V1UJNL1013 D e c l a r a t i o n of Nederlands Meetinstituut Product description Manufacturer Brand Type Serial number(s) Number of tested products Conformity Bio Console Applikon Dependable Instruments B.V. Applikon AD11035 P19196/2 1 This declaration of conformity is issued based on testing a series produced sample of the above-mentioned product(s) in conformity with the following standard: Standard Issue EN 50081-1 (1992), EN 50082-1 (1992), EN 50082-2 (1995). EN 61000-3-2 (1995), EN 61000-3-3 (1995), EN 50082-2 (1995): Table A.4 Positive The measuring results are available at NMi with project number: 10047984 This declaration of conformity is granted under project number: 10047984 Name applicant Address applicant Postal code/City Country Applikon Dependable Instruments B.V. De Brauwweg 13 3125 AE SCHIEDAM The Netherlands Niekerk T.E.T. NMiC Nederlands Meetinstituut P.O. Box 15 9822 ZG Nlekerk (NL) Smldshornerweg 18 9822 TL Niekerk Telephone +31 594 505005 Telefax +31 594 504804 Nederlands Meetinstituut N.V. (Registered at the Chamber of Commerce Delft number 28701} Offices: Delft, Bergum, Utrecht, Dordrecht, Helmond, Niekerk Subsidiary companies: NMi Van Swinden Laboratorium B.V. (28703) NMi Ukwezen B.V. (28700) NMi Certin B.V. (33418) NMi Test- en Adviescentrum (TAQ B.V. (28702) This declaration is issued under the provision that Nederlands Meetinstituut N.V. nor its subsidiary companies accept any liability. Reproduction of the complete certificate is allowed. Parts of the certificate may only be reproduced after written permission. GEBRUIKSMNWIJZING SYMBOLEN ADI 1035 Bio Console Versie 3, oktober 1996 SYMBOLEN De volgende symbolen worden gebruikt op de instrumentatie en in de documentatie: Let op; kijk in de gebruiksaanwijzing. Let op; kans op electrische schok. I Belangrijke opmerking; lees de instructies zorgvuldig. Applikon Dependable Instruments 3125 AE Schiedam Tel.: 010-4621855 <a appiikor? DEPENDABLE INSTRUMENTS De Brauwweg 13 Nederland Fax.: 010-4379648 GEBRUIKSMNWIJZING BASIS BIO CONSOLE ADI 1035 Bio Console Versie 3, oktober 1996 HOOFDSTUK 1 BASIS BIO CONSOLE 1.1 INLEIDING: De ADI 1035 Bio Console is een aandrijvings-console voor gebruik in combinatie met een ADI 1030 Bio Controller. Het ondersteunt de regeling van gassen (met rotameters), regelingen van roersnelheid, niveau, temperatuur (met heet en koud water of met een verwarmingsmantel) en het toevoegen van vloeistoffen met pompen. Tevens wordt de koelwatervoorziening voor de koeler in het reactordeksel ondersteund. Door een zeer compact ontwerp stelt de ADI 1035 Bio Console u in staat om een "bioproces" te voeren op een minimale tafelruimte (de ADI 1030 Shelf-Top Bio Controller past precies bovenop de ADI 1035 Bio Console). Let op: De ADI 1035 Bio Console mag uitsluitend worden gebruikt als een aandrijvings-console voor regelaars bij een biotechnologisch proces! Op de volgende pagina's ziet u voor- en achteraanzicht van de ADI 1035 Bio Console en staan er instructies vermeld ten aanzien van de installatie en aansluitingen. <8 DEPENDABLE INSTRUMENTS 1-1 GEBRUIKSAANWIJZING BASIS BIO CONSOLE ADI 1035 Bio Console Versie 3, oktober 1996 1.2 VOORAANZICHT: B oooo f D E oooo IB22X2? „», Bh Console ADI 1035 o o © o •:6; G -7-® © © © H © I © © ® A = Plaats voor gastoevoervoorziening C = Voedingsgedeelte E = Niveauregeling G = Plaats voor pomp met instelbare snelheid I = Reactor-aansluitingen B = Plaats voor gasselectieblok D = Roersnelheidsregeling F = Temperatuurregeling H = Koeler-aansluitingen J = Pompplaats met vaste snelh. appiikon ($> DEPENDABLE INSTRUMENT'S 1-2 GEBRUIKSAANW1JZING BASIS BIO CONSOLE ADI 1035 Bio Console Versie 3, oktober 1996 1.3 ACHTERAANZICHT: B A H A © © © D E F © © G TZT A = Aansluiting voor afstandsbediening C = Gas-aansluitingen E = Ontluchting G = Netkabel I = Roersnelheidsregeling conn. B = Voeding voor de ADI 1030 D = Water-aansluiting F = Afvoer H = Mass-flow-control conn. N.B.: D Mass Flow Control aansluitingen MFCl tot en met MFC4 (H) zijn voor toekomstig gebruik. Let op: De geschakelde voeding "B" is bedoeld voor de voeding van de ADI 1030 Bio Controller. In het geval dat deze aansluiting wordt gebruikt voor de voeding van andere instrumentatie, is de maximale totale belasting (beide aansluitingen) 250 W. DEPENDABLE INSTRUMENTS 1-3 GEBRUIKSMNWIJZING BASIS BIO CONSOLE ADI 1035 Bio Console Versie 3, oktober 1996 1.4 INSTALLATIE: NETVOEDING: De ADI 1035 Bio Console is inzetbaar in het gehele netvoedingsbereik van 110 tot 240V- (wel moet het apparaat ingesteld zijn voor de juiste spanning): Z310351010 : Bio Console ADI 1035 110 - 240 Vac. Controleer het gekozen voltage (zie de gele voltage-sticker naast de netvoedingskabel); indien het gekozen voltage niet juist is, waarschuw dan uw service-dienst. LET OP! KANS OP ELEKTRISCHE SCHOK! Sluit de netvoedingskabel als volgt op het lichtnet aan: - bruin = fase, - blauw = nul, - groen/geel = aarde. Voedingsgedeelte van de ADI 1035 A = Hoofdvoedingszekeringen B = Aan/uit-schakelaar MAIN POVER FUSES C = Aan/uit indicator D = Centrale alarm indicator ZEKERINGSWAARDE: 220 - 240 V ~ : T 8A, 110-120 V ~ : T 16A. De toegepaste zekeringen moeten voldoen aan IEC 127! De ADI 1035 Bio Console kan nu worden ingeschakeld met de "Power On/Off" schakelaar. De "Alarm" LED kan worden gebruikt als algemene alarm indicatie voor sensor-waarden (alarmen op de ADI 1030 moeten worden toegewezen aan uitgang 3; niveau-detectieschakeling moet "aan" zijn (zie hoofdstuk 7: schakelaarstanden)). toapplikorf ^ • ^ DEPENDABLE INSTRUMENTS 1-4 GEBRUIKSAANWIJZING ADI 1035 Bio Console BASIS BIO CONSOLE Versie 3. oktober 1996 GASTOEVOER: Indien een of meerdere rotameters zijn geplaatst, dient de overeenkomstige gastoevoer te worden aangesloten op de daarvoor bestemde schotkoppeling aan de linkerzijde van de ADI 1035 Bio Console; zie hoofdstuk 2: Gastoevoer. WATERTOEVOER: Indien het waterbad, de koudwaterklep of de koeler toegepast worden, dient kraanwater met een gereduceerde druk (30-50 kPa, 0.3-0.5 bar, 4-7 psi) aangesloten te worden aan de linker zijkant van de ADI 1035 Bio Console; zie hoofdstuk 3: Temperatuurregeling. Centraal in het pompgedeelte zit een naaldventiel waarmee de koelwaterstroom naar de koeler op het reactordeksel geregeld kan worden. Daaronder zitten twee snelkoppelingen voor slangaansluitingen van en naar de koeler; de koppeling naar de koeler bevat een terugslagklep waardoor de koeler niet leegloopt wanneer deze aansluiting wordt losgemaakt. Onder de aansluitingen voor de koeler zitten twee wateraansluitingen voor de reactormantel (van en naar de mantel); ook hier zit in de koppeling naar de reactor een terugslagklep waardoor de snelkoppeling losgemaakt kan worden zonder dat de reactormantel leegloopt. <Sappiikorf DEPENDABLE INSTRUMENTS GEBRUIKSMNWUZING ADI 1035 Bio console BASIS BIO C O N S O L E Versie 3, oktober 1996 AANSLUITING VAN DE ADI 1035 AAN DE ADI 1030 CONTROLLER: Wanneer de ADI 1030 Bio Controller wordt gebruikt in combinatie met de ADI 1035 Bio Console, dan MOET de ADI 1030 worden gevoed vanuit de ADI 1035; hierdoor kan het gehele systeem afgeschakeld worden door de aan/uit-schakelaar van de ADI 1035. De volgende kabels zijn beschikbaar: Z510303200 Netvoedingskabel voor het processordeel van de ADI 1030, Z510303210 Netvoedingskabel voor de uitgangsmodule van de ADI 1030, Z510303220 Regelkabel (regelingssignaal vanuit de ADI 1030 naar de ADI 1035). LET OP! INDIEN DE PROCESREGELAAR (B1JVOORBEELD DE ADI 1030) NIET GEVOED WORDT VANUIT DE ADI 1035, MOET DE VOEDING VANUIT DE REGELAAR AAN DE ADI 1035 WORDEN AANGEBODEN. KIJK IN HOOFDSTUK 7.2 VOOR INSTRUCTIES T.A.V. AANSLUITING EN SCHAKELAAR-STAND! De voedingskabels passen in de stekkerbussen aan de achterkant van de ADI 1035. De status van de ADI 1035 aandrijvers wordt bepaald door de uitgangssignalen van de ADI 1030 Bio Controller; de regelkabel moet worden gebruikt voor de aansluiting tussen de uitgangs-module van de ADI 1030 en de aansluiting voor afstandsbediening op de ADI 1035 (achterzijde). De regelkabel moet op de volgende manier op de ADI 1030 Bio Controller worden aangesloten (zie tabel op de volgende pagina): LET OP! KANS OP ELEKTRISCHE SCHOK! SCHAKEL DE VOEDING VAN DE ADI 1035 /1030 COMBINATIE AF ALVORENS ENIGE AANSLUITING TE MAKEN! appiikorrf DEPENDABLE INSTRUMENTS 1-6 GEBRUIKSMNWIJZING BASIS BIO CONSOLE ADI 1035 Bio Console Versie 3, oktober 1996 ADI 1030 Uitgangsnr. ADI 1030 Klem Draadkleur ADI 1035 Aandrijver Uitgang 1 X1-1 WH (wit) Pomp 1 Uitgang 2 X1-4 BR (bruin) Pomp 2 Uitgang 3 X1-7 GN (groen) Pomp 3 of Alarm Uitgang 4 X1-10 YE (geel) Rotameterklep 1 Uitgang 5 X1-13 GR (grijs) Rotameterklep 2 Uitgang 6 X1-1B PK (paars) Rotameterklep 3 Uitgang 7 X1-19 BL (blauw) Rotameterklep 4 Uitgang 8 XI-22 RD (rood) Verwarming Uitgang 9 X1-25 BK (zwart) Koeling N.B.: Uitgang 3 van de ADI 1030 Bio Controller kan worden gebruikt om pomp 3 van de ADI 1035 te regelen (in dit geval mag er geen niveau-regeling geplaatst zijn in de ADI 1035) of als centrale alarm-indicator (LED) in het voedingsgedeelte van de ADI 1035 (wanneer er wel een niveau-regeling geplaatst is in de ADI 1035). Zie ook hoofdstuk 5 (niveau-regeling) en hoofdstuk 7 (schakelaarstanden). EXTERNE AANSLUITINGEN: Gastoevoer-schotkoppelingen: slang: ID 4 mm max. druk: 200 kPa (2 bar, 29 psi) Watertoevoer: slang: ID 6 mm max. druk: 50 kPa (0.5 bar, 7 psi) min. druk: 30 kPa (0.3 bar, 4 psi) Koeleraansluitingen: slang: ID 6 mm Reactormantelaansluitingen: slang: ID 6 mm <S DEPENDABLE INSTRUMENTS 1-7 GEBRUIKSMNWIJZING ADI 1035 Bio Console BASIS BIO CONSOLE Versie 3, oktober 1996 OMGEVINGSCONDITIES: De ADI 1035 Bio Console kan worden gebruikt op lokaties met de volgende omgevingscondities: - Gebruik binnenshuis, Hoogte: tot 2000 meter boven zeeniveau, Omgevingstemperatuur: 4°C - 45°C, Maximum relatieve vochtigheid: 80% voor temperaturen tot 31°C, lineair afinemend tot 50% bij 45°C, - Voedingsspanning: 115/230 Vac (+15%/-20%), 50/60 Hz, - Transciente overvoltages volgens INSTALLATIE CATEGORIE II, - VERVUILINGSGRAAD 2 volgens IEC 664. I I DEPENDABLE INSTRUMENTS 1-8 GEBRUIKSMNW1JZING GASTOEVOER ADI 1035 Bio Console Versie 3, oktober 1996 HOOFDSTUK 2 GASTOEVOER 2.1 HET GASTOEVOERGEDEELTE: Het ADI 1035 Gastoevoergedeelte ondersteund de toepassing van vier rotameters en een gasselectieblok: A = Gasselectiekleppen Het optioneie gasselectieblok bevat vier gasselectiekleppen. Met deze kleppen wordt het type gastoevoer ("sparging" of "overlay") gekozen. N.B.: - De bovenste gasinlaatkoppeling komt overeen met de linker rotameter en de bovenste klep van het gasselektieblok. Ordernummer van het gasselektieblok: Ordernummer van een gasuitlaatkoppeling: Op de volgende pagina staan de rotameters vermeld. Z311302020 Z311302060 (gapplikorf ^ • ^ DEPENDABLE INSTRUMENTS 2-1 GEBRUIKSAANW1JZING GASTOEVOER ADI 1035 Bio Console Versie 3, oktober 1996 Beschikbare rotameters: Z3RM000005 Rotameter Z3RM000010 Rotameter Z3RM000020 Rotameter Z3RM000030 Rotameter Z3RM000040 Rotameter Z3RM000050 Rotameter Z3RM000060 Rotameter Z3RM000070 Rotameter Z3RMOOOO8O Rotameter assembly assembly assembly assembly assembly assembly assembly assembly assembly 2.5 - 25 ml/min, 5 . 0 - 5 0 ml/min, 9.0 - 90 ml/min, 27 - 270 ml/min, 50 - 500 ml/min, 0.1-1.0 1/min, 0.5 - 5.0 1/min, 1.0 - 10 1/min, 2.3 -23 1/min. Rotameters kunnen worden toegepast met of zonder klep: A = Rotameter B A - - B = Elleboog C I C = Terugslagklep D = Bevestigingsplaat E = Gas-in F = Gas naar reactor Rotameter A + C = Inschroefkoppeling -A B B = Slang D = "Solenoid"-klep -C D E = Montagemateriaal G = Gas-in F = Gas naar reactor Rotameter met klep-module <8 i i DEPENDABLE INSTRUMENTS 2-2 GEBRUIKSAANWIJZING GASTOEVOER ADI 1035 Bio Console Versie 3, oktober 1996 De klep-raodule is leverbaar in twee verschillende versies: Z311302040 Valve Module for Rotameter Ass., 220 - 240 Vac, Z311302045 Valve Module for Rotameter Ass., 110 - 120 Vac. LET OP: INDIEN ZUURSTOF WORDT TOEGEPAST ALS EEN VAN DE GASSEN, DAN DIENEN VOOR INSCHAKELING VAN DE NETSPANNING DE KOPPELINGEN EN SLANGEN OP LEKKEN TE WORDEN GETEST! N.b.: - De rotameterkleppen kunnen worden geschakeld door de digitale uitgangen 4 t/m 7 van de ADI 1030 Bio Controler; zie hoofdstuk 1.4 van deze gebruiksaanwijzing: Installatie. I I DEPENDABLE INSTRUMENTS 2-3 GEBRUIKSAANW1JZING TEMPERATUURREGELING ADI 1035 Bio Console Versie 3, oktober 1996 HOOFDSTUK 3 TEMPERATUURREGELING 3.1 TEMPERATUURREGELINGSGEDEELTE: A = Netvoedings-indicatie B = Max. temperatuur-indicatie C = Koeling-indicatie D = Verwarmings-indicatie E = Stopcontact voor verwarming F = Voedingszekering G = Max. temperatuurs-instelling H = Aan / uit / vul-schakelaar ZEKERINGSWAARDE: 220- 240 V~: T 3.15A, 110- 120 V~: T 6.3A. De toegepaste zekeringen moeten voldoen aan IEC 127! Het temperatuurregelingsgedeelte verzorgt verwarmen en koelen door middel van verschillende principes: In de Basis Lay-Out is het aansturingssignaal voor verwarmen (uitgang 8 van de ADI 1030) doorgeschakeld naar het stopcontact in het temperatuurregelingsgedeelte. Hierop kan een verwarmingsmantel worden aangesloten (temperatuurregeling met slechts een aansturing). LET OP! KANS OP ELEKTRISCHE SCHOK. ZODRA AANSTURING WORDT INGESCHAKELD, WORDT DE NETSPANNING DIRECT DOORGESCHAKELD NAAR HET STOPCONTACT! MAXIMAAL VERMOGEN = 400 W. DEPENDABLE INSTRUMENTS 3-1 GEBRUIKSAANWIJZING ADI 1035 Bio console TEMPERATUURREGELING Versie 3, oktober 1996 N.B.: - In dit geval worden de indicaties voor de maximum temperatuur van het waterbad en het koelen niet gebruikt. - Met de aan/uit-schakelaar in de middelste (Vul) stand is de temperatuurregeling operationeel. Met een extra koudwaterklep in de ADI 1035 kan een dubbele temperatuurregeling tot stand worden gebracht (verwarmen en koelen). Het aandrijvingssignaal voor koelen (uitgang 9 van de ADI 1030) wordt doorgeschakeld naar deze koudwaterklep. N.B.: - In dit geval is de indicatie voor de maximum temperatuur van het waterbad niet in gebruik. - Met de aan/uit-schakelaar in de middelste (Vul) stand is de temperatuurregeling operationeel. Een andere manier van dubbele temperatuurregeling is de toepassing de waterbadmodule voor de ADI 1035. Op deze manier wordt de temperatuur geregeld door heet of koud water rond te pompen. N.B.: - In dit geval is het stopcontact voorop niet in gebruik. In geval het waterbad of de koudwaterklep wordt toegepast of koud water nodig is voor de koeler op het reactordeksel, dient leidingwater met gereduceerde druk te worden aangesloten (bovenste koperen koppeling aan de linkerzijde van de ADI 1035); inlaatdruk: 30 - 50 kPa (0.3 - 0.5 bar, 4 - 7 psi). Een waterdruk-reduceerventiel is leverbaar. De onderste koperen koppeling wordt gebruikt om water af te voeren, de middelste koppeling is voor de ontluchting (lucht uit het circulatie-systeem). Hieronder staat de order-informatie van alle toepasbare modulen vermeld: Z310180030 Z310180040 Z310180060 Z310180070 Z310180050 Z311020022 Z311020030 Z311020050 Z311020070 Z311020150 Thermo-circulator module 220 - 240 Vac, ADI 1035, Thermo-circulator module 110 - 120 Vac, ADI 1035. Cold water valve module 220 - 240 Vac, ADI 1035, Cold water valve module 110-120 Vac, ADI 1035. Water pressure reducer for ADI 1018. Silicone heating blanket, 2 liter reactor, 230 Vac, Silicone heating blanket, 3 liter reactor, 230 Vac, Silicone heating blanket, 5 liter reactor, 230 Vac, Silicone heating blanket, 7 liter reactor, 230 Vac, Silicone heating blanket, 15/20 liter reactor, 230 Vac. N.B.: - Indien geen temperatuurregeling wordt toegepast, kan de wateraansluiting worden gebruikt voor watertoevoer naar de koeler op het reactordeksel (zie ook 1.4). <a appliko ft DEPENDABLE INSTRUMENTS 3-2 GEBRUIKSAANWIJZING ADI 1035 Bio console TEMPERATUURREGELING Versie 3, oktober 1996 3.2 KOUDWATERKLEP: De koudwaterklep kan worden gebruikt voor het koelen van de reactor; in dit geval stuurt de regelaar (de ADI 1030 Bio Controller) deze klep direct aan. Zodra de reactor te warm wordt, wordt de netspanning direct doorgeschakeld waardoor de klep wordt geopend. Toelaatbare druk voor de koudwaterklep: zie voorgaand hoofdstuk (3.1). Bij gebruik van deze klep heeft de vulpositie van de aan / uit-schakelaar geen functie en is de instellingsknop voor de maximum-temperatuur van het waterbad afwezig; de temperatuurregeling is echter wel actief!. (8appiikorff DEPENDABLE INSTRUMENTS 3-3 GEBRUIKSMNWIJZING TEMPERATUURREGELING ADI 1035 Bio Console Versie 3, oktober 1996 3.3 WATERBAD-MODULE: SCHEMATISCHE LAY-OUT: ^~f~mmm B H K A = Warmtewisselaar C = Terugslagklep E = Veiligheidsklep G = Drukreduceer I = Naar Reactor K = AfVoer B = Circulatie Pomp D = Ontluchtingsventiel F = 2-Wegklep H = Waterinlaat J = Vanuit Reactor L = Ontluchting N.B.: - De aansluitingen "To -" en "From Condenser" worden niet getoond in deze lay-out. - De warmtewisselaar bevat een Thermo Element en een Thermo Schakelaar die het Thermo Element uitschakelt zodra de maximaal toegestane temperatuur van het waterbad wordt bereikt. LET OP: WANNEER HET WATERBAD LEEG WORDT AANGEZET, ZULLEN DE KERAMISCHE LAGERS VAN DE CIRCULATIEPOMP BESCHADIGEN. ,® DEPENDABLE INSTRUMENTS 3-4 GEBRUIKSAANWIJZING ADI loss Bio console TEMPERATUURREGELING Versie 3, oktober 1996 Zodra de netvoeding wordt ingeschakeld met de aan/vul/uit-schakelaar (middelste of bovenste positie) wordt de circulatiepomp gestart. De temperatuurregelaar (ADI 1030 Bio Controller) kan het verwarmingselement of de koeling aansturen; ingeval van koeling wordt de afvoerklep geopend, waardoor warm water kan wegstromen en koel leidingwater in het circulatiesysteem wordt toegelaten. De ontluchtingsklep is een gasdoorlaatbare klep, waardoor lucht in het circulatie-systeem wordt afgevoerd. De veiligheidsklep is in het circulatie-systeem opgenomen om te hoge drukken te voorkomen; bij een interne druk van ongeveer 100 kPa (1 bar, 14 psi) gaat deze klep open (circulatiewater gaat naar de afvoer) totdat de druk weer is afgenomen. GEBRUIK VAN HET WATERBAD: De waterbad-module voor de ADI 1035 kan in werking worden gesteld door de onderstaande stappenlijst te volgen: - Sluit het ADI 1035 waterbad aan op de warmtewisselaar in de reactor of op de mantel van de reactor d.m.v. slang met ID 6 mm (gebruik slangenklemmen om het losschieten van slangen te voorkomen). De "To Reactor" koppeling bevat een terugslagklep; de "From Reactor" koppeling is van binnen open. - Sluit slangen (ID = 6 mm) aan op de afvoer- en ontluchtingskoppelingen om op deze manier water en lucht naar een open afvoer te leiden. - Sluit leidingwater met gereduceerde druk (max. inlaatdruk van 500 kPa (= 0.5 bar, 7 psi)) aan op de waterinlaat; gebruik hiervoor slang ID = 6 mm. Water stroomt nu het circulatie-systeem in; lucht verlaat het waterbad door de ontluchting. - Sluit de netkabel aan op het netvoedingsstopcontact. - Het vullen van het waterbad wordt versneld door de aan/vul/uit-schakelaar van het waterbad in de middelste (Fill) stand te zetten; de 2-wegklep wordt nu geopend en zodra het waterbad gevuld is, stroomt het water naar de afvoer. Zodra dit het geval is, kan de aan/uit/vul-schakelaar aan of uit worden gezet. Alle achtergebleven luchtbellen zullen worden afgevoerd door de ontluchtingsklep. Indien de circulatiepomp herrie maakt, dan zit er veel lucht in de pomp; schakel voor ca. 15 seconden terug naar de vulstand. Regel de maximum waterbadtemperatuur "Max. Loop Temperature" zo in, dat er geen lokale "hot-spots" in de reactor kunnen voorkomen. Het omlaag brengen van de maximale waterbadtemperatuur vermindert natuurlijk de maximale warmteoverdracht van het waterbad. appkorf DEPENDABLE INSTRUMENTS 3-5 GEBRUIKSAANWIJZING ADI 1035 Bio console TEMPERATUURREGELING Versie 3, oktober 1996 N.B.: De interne maximale waterbadtemperatuur = ca. 95°C; de maximale temperatuur van het water in het rondpompsysteem = ca. 80°C. Het ADI 1035 waterbad is nu klaar om in gebruik te worden genomen. ONDERHOUD: Indien de waterbadtemperatuur hoog is ingesteld (>80°C) en koelwater regelmatig in het systeem wordt toegelaten, kan het verwarmingselement door kalkaanslag vervuilen waardoor de warmteoverdracht afneemt. Indien dit het geval is, dient de ADI 1018 te worden teruggestuurd voor service. Raadpleeg uw service-dienst. DEPENDABLE INSTRUMENTS 3-6 GEBRUIKSAANWiJZING ROERSNELHEIDSREGELING ADI 1035 Bio Console Versie 3, oktober 1996 HOOFDSTUK 4 ROERSNELHEIDSREGELING 4.1 MOTORREGELING: De ADI 1035 Bio Console kan worden uitgerust met twee verschillende typen motorregelingen; de een voor de roermotoren P100, P140 en P310, de andere voor de roermotor PI000. Motorregelingsgedeelte: A = Spannings/"overload" ind. B = Snelheidsweergave (r.p.m.) C = Roermotoraansluiting D = Hand/afstands-schakelaar E = Motorzekering F = Regelaarzekering G = Potmeter roersnelheid H = Aan/uit-schakelaar Let op: - Volgens wetgeving van de Europese Gemeenschap is de roermotor een machine met mogelijk aanrakingsgevaar. Kijk in de gebruiksaanwijzing van de roermotor voor veiligheidsinstructies, zekeringwaarden, functionaliteit en gebruik. - In het geval de roermotorregeling voor de P1000 motor is geinstalleerd, mag de motorkabel niet worden verwijderd terwijl de voedingsspanning (H) is ingeschakeld; de spanning op de connectoren kan de 60V (gelijkspanning) overschrijden! Met de aan/uit tuimelschakelaar kan de motorregeling worden aan/uitgezet; de "power/overload" indicator is groen zodra de voeding is ingeschakeld, in geval het maximum leverbare koppel wordt bereikt verkleurt de indicator naar rood. Het "liquid cristal display" geeft het actuele aantal toeren per minuut aan. <a DEPENDABLE INSTRUMENTS 4-1 GEBRUIKSAANW1JZING ROERSNELHEIDSREGELING ADI 1035 Bio Console Versie 3, oktober 1996 De "Local/Remote" tuimelschakelaar wordt gebruikt om van handbediening over te schakelen op afstandsbediening: "Local" = roersnelheid wordt met de hand ingesteld (potmeter op voorzijde), "Remote" = roersnelheid wordt geregeld door een extern 4 - 2 0 mA signaal (bijv. vanuit de ADI 1030 Bio Controller). De kabelaansluiting voor de roermotor is op de voorzijde geplaatst; de aansluiting voor afstandsbediening door de ADI 1030 Bio Controller zit aan de achterkant (9 pins sub-D connector). Orderinformatie voor toepasbare modulen en motoren: Z510354000 Z510354040 Stirrer speed controller P100 - P310 ADI 1035, Stirrer speed controller P1000 ADI 1035, Z5100002M0 Z5100002M1 Z5100002M3 Z51 OOP 1000 Z510000001 Z510000002 Z51 OOP 1005 Stirrer motor assembly P100, Stirrer motor assembly P140, Stirrer motor assembly P310, Stirrer motor assembly P1000, Stirrer motor assembly PI00 1=6, Stirrer motor assembly P140 1=2, Stirrer motor assembly PI000 1=5, Z510121C02 Cable for P100 - P1000 ADI 1035, Z510120900 Control cable motor speed short (ADI 1030), Z510120000 Recalibration of stirrer speed controller (gewenst calibratiebereik moet worden opgegeven). <8 appiikorf DEPENDABLE INSTRUMENTS 4-2 GEBRUIKSAANW1JZING NIVEAUREGELING ADI 1035 Bio Console Versie 3, oktober 1996 HOOFDSTUK 5 NIVEAUREGELING De niveauregelingsmodule van de ADI 1035 Bio Console kan worden gebruikt om een pomp te activeren zodra er vloeistof-contact gemaakt wordt met de niveau-sensor; deze optie kan zowel worden gebruikt als anti-schuim- als niveauregeling. Niveauregelingsgedeelte: A = LED indicatie voor pomp 3 B = Doorvoer voor sensor kabels AUTO POWER D LEVEL SENSOR (Q) (O) C = Aansluiting niveau-sensor D = Voedingszekering E = Aan/uit/auto-schakelaar ZEKERINGWAARDE: 220 - 240 V~: T 1A, 110- 120 V~: T2A. De toegepaste zekeringen moeten voldoen aan IEC 127! Met de tuimelschakelaar in de: "on" positie is pomp 3 altijd aan, "off positie is pomp 3 altijd uit, "auto" positie is pomp 3 aan wanneer er vloeistofcontact is aan de niveau-sensor. De LED indicator geeft de status van pomp 3 aan. Let op: Indien de niveauregelingsmodule is geplaatst, dan kan uitgang 3 van de ADI 1030 worden gebruikt als centrale alarm indicatie (LED op het voedingsgedeelte van de ADI 1035); zie ook hoofdstuk 7 (schakelaarstanden). Indien geen niveauregelingsmodule geplaatst is, kan pomp 3 voor andere doeleinden worden gebruikt (handmatig of met afstandsbediening. appiikoff DEPENDABLE INSTRUMENTS 5-1 GEBRUIKSMNWIJZING ADI 1035 Bio console NIVEAUREGELING Versie 3, oktober 1996 Orderinformatie voor toe te passen modulen: Z510203095 Z510203096 Z71513AF02 Level control module ADI 1035, 220 - 240 Vac, Level control module ADI 1035, 110 - 120 Vac, Cable for level sensor. DEPENDABLE INSTRUMENTS 5-2 GEBRUIKSAANWIJZING POMPEN ADI 1035 Bio Console Versie 3, oktober 1996 HOOFDSTUK 6 POMPEN Het pompgedeelte bevat vier pompposities: B A = Potmeterpositie voor pomp met variabele pompsnelheid B = Positie voor pompaandrijving met variabele snelheid C = Aan/uit/afstands-schakelaar voor pomp 1, 2 en 3 (vaste snelheid) D = Positie voor pompaandrijving 1, 2 en 3 (vaste snelheid) Op pomppositie 1, 2 en 3, kunnen pompaandrijvingen met een vaste snelheid worden geplaatst; de pompen kunnen met de hand of vanaf afstand worden bestuurd (in geval dat de niveauregelings-module is geplaatst, wordt pomp 3 gebruikt voor niveauregeling). Iedere pomp kan met een tuimelschakelaar in de standen aan/uit/afstand gezet worden. Op pomppositie 4 kan een pompaandrijving met variabele snelheid worden geplaatst voor handmatig gebruik. appiikon' DEPENDABLE INSTRUMENTS 6-1 GEBRUIKSAANWIJZING POMPEN ADI 1035 Bio Console Versie 3, oktober 1996 Let op: Volgens wetgeving van de Europese Gemeenschap is een pompaandrijving een machine met potentieel gevaar. Pas bij deze aandrijvingen uitsluitend de pompkoppen en slangen toe die hieronder worden vermeld! Gebruik de slangenpompaandrijvingen niet voor andere doeleinden dan het verplaatsen van vloeistoffen (of gassen). Schakel de voeding van de pompaandrijving af alvorens slangen of pompkoppen te vervangen. Gebruik van beschadigde slangen kan tot gevolg hebben dat vloeistof in de aandrijving lekt! Controleer de kwaliteit van de slang in de pompkop voor de start van elk fermentatieproces. De volgende twee typen pompkoppen kunnen op de aandrijvingen worden gebruikt: FLOW DIRECTION Masterflex Easy-Load pompkop Standaard Masterflex pompkop De pompaandrijving met variabele snelheid heeft een interne zekering. Zekeringwaarde: 250 V~ T 0,8A. De toegepaste zekeringen moeten voldoen aan IEC 127! Orderinformatie betreffende de toepasbare pompkoppen en slangen vindt u op de volgende pagina: DEPENDABLE INSTRUMENTS 6-2 GEBRUIKSAANWIJZING POMPEN ADI 1035 Bio Console Versie 3, oktober 1996 Z311500010 Z311500011 Z311500020 Z311500021 Z311600010 Z311600011 Z311500005 Z3 75180000 Z375180200 Z370132000 Z3 70142000 Z370152000 Z3 70162000 Z370182000 Fixed speed drive 5 rpm, 220 - 240 Vac, ADI 1035, Fixed speed drive 6 rpm, 110 - 120 Vac, ADI 1035, Fixed speed drive 17 rpm, 220 - 240 Vac, ADI 1035, Fixed speed drive 20 rpm, 110 - 120 Vac, ADI 1035, Variable speed drive 10 - 120 rpm, 220 - 240 Vac, ADI 1035, Variable speed drive 10 - 120 rpm, 110 - 120 Vac, ADI 1035, Blind plate for unused pump position, Easy-load pump head for thin wall tubing, Easy-load pump head for thick wall tubing, Standard pump head 7013-20, Standard pump head 7014-20, Standard pump head 7015-20, Standard pump head 7016-20, Standard pump head 7018-20. Beschikbaar slangmateriaal: - Norprene Food (zeer lange levensduur en chemisch inert), - Siliconen, - Pharmed. DEPENDABLE INSTRUMENTS 6-3 GEBRUIKSMNWIJZING DOORVERBINDINGEN ADI 1035 Bio Console Versie 3, oktober 1996 HOOFDSTUK 7 DOORVERBINDINGEN Naast de inbouwinstructies op de Documentatie-tekeningen (zie hoofdstuk 8 van de Engelse versie van deze gebruiksaanwijzing) moeten de doorverbindingen op het ADI 1035 controller board (gelegen net onder de scheidingsplaat) overeenkomen met de gekozen configuratie: - SI: wel of geen waterbad - S2: Intern / Extern (voeding van de aandrijvingssignalen) - S3: wel of geen niveauregeling LEDS © ® .22. 0 0 0 AUttU NEXT. LEXT, X3 HCAWC l i SI S3 1YZ.U-. ® , L . . . . .1,1. . . . . . . HCABNC BL/COtD n COOUHC I I I® 0 0 v w' p. s\. / \ X11 r\ r\ /^ A K A A AX6A ^ A , o o "Central Control Board" Standaard doorverbindingen: - SI: Geen waterbad - S2: Interne voeding van aandrijvingssignalen - S3: Geen niveauregeling appiikorf DEPENDABLE INSTRUMENTS 7-1 GEBRUIKSAANW1JZING DOORVERBINDINGEN ADI 1035 Bio Console Versie 3, oktober 1996 7.1 WATERBAD: In geval de waterbad-module Z31018003/40 is geplaatst, moeten de draadbruggen op SI als volgt worden geplaatst: si 9 NO THERM.CIRC./THERM.CIRC. Connector X27 dient te worden verwijderd van X2 op het "Central Control Board" en geplaatst worden op connector X2 op het "Controller Board" van het waterbad. Connector X28 dient te worden verwijderd van XI op het "Central Control Board" en geplaatst worden op connector XI op het "Controller Board" van het waterbad. Het verwarmings-uitgangssignaal van de teraperatuurregeling moet worden aangeboden op pin 8 van de "Remote Control Connector". Het koelings-uitgangssignaal van de temperatuurregeling moet worden aangeboden op pin 9 van de "Remote Control Connector". Zie ook 7.4. 7.2 VOEDING VAN DE REGELAAR: Indien de netvoedingskabels van de regelaar (de ADI 1030 Bio Controller) aangesloten worden op de MAINS SUPPLY CONNECTORS FOR ADI 1030, hoeft aan de draadbruggen in S2 niets gedaan te worden. Indien de netvoedingskabels van de S2 regelaar (de ADI 1030 Bio Controller) niet • zijn aangesloten op de MAINS SUPPLY CONNECTORS FOR ADI 1030, maar op • een eigen voeding, moeten de draadbruggen in S2 als volgt geplaatst te zijn: Tevens moet deze voeding van de regelaar ook worden aangeboden op de "REMOTE CONTROL CONNECTOR" aan de achterzijde van de ADI 1035 (fase = pin-11, nul = pin-12). Zie ook 7.4. De geschakelde voeding kan een totaal vermogen leveren van 250 W. <a appiikorf DEPENDABLE INSTRUMENTS 7-2 GEBRUIKSMNWIJZING DOORVERBINDINGEN ADI 1035 Bio Console Versie 3, oktober 1996 7.3 NIVEAUREGELAAR: In geval de niveauregelaar is geplaatst (op XI4, binnen-achterzijde) moeten de draadbruggen op S3 als volgt te worden geplaatst: t £ Z NO LEVEL DET./LEVEL DET Aandrijver voor niveau-detectie: pomp 3 (pompschakelaar moet in de stand "Remote" staan). In dit geval kan pin 3 van de "Remote Control Connector" (achterop de ADI 1035) worden gebruikt als centrale alarm voor de regelaar (LED indicatie op het voedingsgedeelte van de ADI 1035). Indien schakelaar S3 in de stand "No Level Detector" staat, kan pomp 3 gebruikt worden voor handmatige bediening of afstandsbediening. 7.4 REMOTE CONTROL CONNECTOR: REMOTE CONTROL De 12-pins aansluiting voor afstandsbediening aan de achterzijde van de ADI 1035 Bio Console heeft de volgende lay-out: 12 3 4 5 6 7 8 9101112 DDDDDanDDDDD Aansluitings Pinno. Functie 1 Pomp 1 2 Pomp 2 3 Pomp 3 of Alarm 4 Rotameterklep 1 5 Rotameterklep 2 6 Rotameterklep 3 7 Rotameterklep 4 8 Verwarmings-element 9 Koel-element 10 Alarm 11 Externe Fase 12 Externe Nul 0 DEPENDABLE INSTRUMENTS 7-3 GEBRUIKSMNW1JZING TEKENINGEN ADI 1035 Bio Console Versie 3, oktober 1996 HOOFDSTUK 8 TEKENINGEN De volgende tekeningen gebruiksaanwijzing: D103 5-3 .12.101 D1035-1 .12.002 D1035-la.12.020 D1035-1 .12.202 D1035-la.12.206 Dl018-2b. 12.003 D1035-lc.12.106 D1035-la.12.400 D1035-la.12.404 D1035-lc.12.110 D1035-lb.12.220 D1035-1 .12.000 zijn opgenomen in de Engelse versie van deze Bio console basic 110 - 240V ADI 1035 Rotameter assembly Valve module for rotameter Basic gas selection block Gas outlet bulkhead connector set Thermo circulator module 110 - 220V ADI 1035 Cold water valve 110/220V ADI 1035 Stirrer speed contr. P100 - 310 ADI 1035 Stirrer speed contr. P1000 ADI 1035 Fixed speed drive 5/20 rpm ADI 1035 Var. speed drive 10 - 120 rpm ADI 1035 Blind plate for pump position ADI 1035 <2 DEPENDABLE INSTRUMENTS 8-1 USER MANUAL ADI 1035 Bio Console Version 3, November 1996 BIO CONSOLE ADI 1035 INSTRUMENT MANUAL 1. Basic unit 2. Gas supply 3. Temperature control 4. Stirrer speed control 5. Level control 6. Pumps 7. Switch settings 8. Drawings appiKorf DEPENDABLE INSTRUMENTS V1UJCE1013 USER MANUAL SYMBOLS ADI 1035 Bio Console Version 3, November 1996 SYMBOLS The following symbols are used on equipment and documentation: Caution; refer to this user manual. Caution; electrical shock hazard. I Importent note; read the instructions carefully. Applikon Dependable Instruments 3125 AE Schiedam Tel.: (31 )(0)10-4621855 appiikort DEPENDABLE INSTRUMENTS De Brauwweg 13 The Netherlands Fax.:(31)(0)10-4379648 CE CONFORMITY EU DECLARATION OF CONFORMITY The company Applikon Dependable Instruments B.V., Schiedam, The Netherlands, hereby certifies that the instrument: AD11035 BIO CONSOLE meets the requirements of the EU Directives 89/336/EEC (Electromagnetic Compatibility) and 73/23/EEC (Low Voltage). SOURCE OF THE SPECIFICATIONS: 89/336/EEC: 73/23/EEC EN 50081-1 (1992) EMC Generic emission standard. Residential, commercial and light industry. EN 61000-3-2 (1995) EMC Limits for harmonic current emissions (equipment input current < 16A per phase). EN 61000-3-3 (1995) EMC Limits concerning voltage fluctuations and flicker for equipment having an input current up to and including 16 A per phase. EN 50082-1 (1992) EMC Generic immunity standard. Residential, commercial and light industry. EN 50082-2 (1995) EMC Generic immunity standard. Industrial environment (including table A.4). EN 61010 Safety requirements for electrical equipment for measurement, control and laboratory use. ing J. van Burg, President. Applikon Dependable Instruments 3125 AE Schiedam Tel.: (31 )(0)10-2983555 appiikorf DEPENDABLE INSTRUMENTS 23.10.96 De Brauwweg 13 The Netherlands Fax.: (31 )(0)10-4379648 USER MANUAL BASIC UNIT ADI 1035 Bio Console Version 3, November 1996 CHAPTER 1 BIO CONSOLE BASIC UNIT 1.1 INTRODUCTION: The ADI 1035 Bio Console is an actuator console that can be used in combination with an ADI 1030 Bio Controller. It supports gas flow regulation (with rotameters), stirrer speed control, level control, temperature control (with hot and cold water or heating blanket) and liquid addition with pumps. It also supports tuning the flow of cooling medium to the condenser. Because of its compact design, the ADI 1035 Bio Console allows you to run a bioprocess on a minimum amount of bench space (the ADI 1030 Shelf-Top Bio Controller is designed to be placed on top of the ADI 1035 Bio Console). Caution: The ADI 1035 Bio Console is designed as an actuator console for bio process control and must not be used for other purposes! On the next pages, the front and rear view are presented and the installation instructions and external connections are described. applikorf DEPENDABLE INSTRUMENTS 1-1 USER MANUAL BASIC UNIT ADI 1035 Bio Console Version 3, November 1996 1.2 FRONT VIEW: B oooo D E ®@ oooo Bio Conxlt ADI 1035 o o O •O: © 0— -e o o © © H @- © © I ®© G © A = Gas supply unit C = Power section E = Level control G = Variable speed pump drive I = Reactor connections © © B = Gas selection block D = Stirrer speed control F = Temperature control H = Condenser connections J = Fixed speed pump drive appikorf DEPENDABLE INSTRUMENTS 1-2 USER MANUAL BASIC UNIT ADI 1035 Bio Console Version 3, November 1996 1.3 REAR VIEW: A I H © © A = Remote control connector C = Gas inlet connections E = Drain G = Mains inlet cable I = Stirrer speed control connector © © © © B = Power socket for ADI 1030 D = Water inlet connection F = Air vent H = Mass flow control connectors Note: The Mass Flow Control Connectors MFCl through MFC4 (H) are for future use. Caution: The switched power supply "B" (2 Euro-outlets) is ment for the ADI 1030 Bio Controller supply. In case these sockets are used for the power supply of other hardware, the total maximum load for both sockets = 250 VA. appiikort DEPENDABLE INSTRUMENTS 1-3 USER MANUAL BASIC UNIT ADI 1035 Bio Console Version 3, November 1996 1.4 INSTALLATION: MAINS SUPPLY: The ADI 1035 Bio Console is available in a universal voltage version: Z310351010 : Bio Console ADI 1035 110-240 Vac. Verify the selected voltage (see voltage sticker at the main supply cable gland); if this selection is not correct, contact your service office. CAUTION! ELECTRICAL SHOCK HAZARD! Connect the main supply cable to the line voltage: - brown = live wire, - blue = neutral wire, - green/yellow = earth wire. Power Section of the ADI 1035 A = Main power fuses B = Power on/off switch C = Power-on indicator D = Central alarm indicator Main fuse rating: 220 - 240 V: T 8A, 110-120 V: T16A. Applied fuses must comply with IEC 127! The ADI 1035 Bio Console can now be switched on/off with the "Power On/Off switch. The "Alarm" LED can be used for a general alarm status indication of sensor values (alarms on ADI 1030 must be configured to output 3; level detector switch setting must be positive (see chapter 7: switch settings)). cippiikorf DEPENDABLE INSTRUMENTS 1-4 USER MANUAL ADI 1035 Bio Console BASIC UNIT Version 3, November 1996 GAS SUPPLY: If one or more gas flow regulators (rotameters) are installed, the corresponding gas supplies must be connected to the blue bulkhead connectors at the left hand side of the ADI 1035 Bio Console; see chapter 2: Gas Supply. WATER SUPPLY: If the thermo-circulator module, cold water valve or condenser is installed, reduced water supply (30-50 kPa, 0.3-0.5 bar, 4-7 psi) must be connected at the left hand side of the ADI 1035 Bio Console; see chapter 3: Temperature Control. In the center of the pump section, a tuning valve is located for cooling water to the condenser at the head plate of the bioreactor. The bulkhead connectors for water to and from the condenser are quick-connectors; the nipple to the condenser also contains a check-valve so the condenser will not be drained when the nipple is disconnected. Below the condenser bulkhead connnectors, two bulkhead connectors can be found for water to and from the reactor; these are also quick-connectors, where the nipple to the reactor contains a check-valve to prevent draining of the reactor-jacket (or heat exchanger) when the nipple is disconnected. cippikorf DEPENDABLE INSTRUMENTS 1-5 USER MANUAL BASIC UNIT ADI 1035 Bio Console Version 3, November 1996 CONNECTION OF THE ADI 1035 TO THE ADI 1030 BIO CONTROLLER: When the ADI 1030 Bio Controller is used in combination with the ADI 1035 Bio Console, the Mains Power for the ADI 1030 SHOULD be supplied through the ADI 1035; as a result, the complete system can be switched off by the Main Power switch of the ADI 1035. Use the following cables: Z510303200 Cable power supply micro processor part of ADI 1030, Z510303210 Cable power supply output module of ADI 1030, Z510303220 Control cable (controller output from ADI 1030 to ADI 1035). CAUTION! ELECTRICAL SHOCK HAZARD. WHEN THE CONTROLLING DEVICE (ADI 1030 OR ANY OTHER) DOES NOT OPERATE ON THE MAINS FROM THE ADI 1035, REFER TO CHAPTER 7.2 FOR PROPER SWITCH SETTING AND REMOTE CONNECTION! The power cables fit in the switched-power sockets at the rear side of the ADI 1035. The status of the ADI 1035 actuators depend on the outputs of the ADI 1030 Bio Controller; the control cable should be used for connection between the ADI 1030 Output Module and the Remote Control connector of the ADI 1035 (rear side). The control cable must be connected to the ADI 1030 Bio Controller in the following way (see next page): CAUTION! ELECTRICAL SHOCK HAZARD. MAKE SURE THAT THE POWER OF THE ADI 1035 / 1030 IS SWITCHED OFF BEFORE MAKING ANY CONNECTIONS! Note: The ADI 1030 Bio Controller comes with ferrite beads (in two sizes). The larger one must be connected on the control cable near the ADI 1030! cippikorf DEPENDABLE INSTRUMENTS 1-6 USER MANUAL BASIC UNIT ADI 1035 Bio Console Version 3, November 1996 ADI 1030OutpjjtNbr. ADI 1030 Terminal Wire Color ADI 1035 Actuator Output 1 X1-1 WH (white) Pump 1 Output 2 X1-4 BR (brown) Pump 2 Output 3 X1-7 GN (green) Pump 3 or Alarm Output 4 X1-10 YE (yellow) Rotameter Valve 1 Output 5 X1-13 GR (grey) Rotameter Valve 2 Output 6 X1-16 PK (pink) Rotameter Valve 3 Output 7 X1-19 BL (blue) Rotameter Valve 4 Output 8 X1-22 RD (red) Heating Element Output 9 X1-25 BK (black) Cooling Element Note: Output 3 from the ADI 1030 Bio Controller can be used to control pump 3 in the ADI 1035 (only when no level control module is installed in the ADI 1035) or as a central alarm output to the Alarm LED in the power section of the ADI 1035 (only when the level control module is installed in the ADI 1035). Also refer to chapter 5 (level control) and chapter 7 (switch settings). EXTERNAL CONNECTIONS: Gas inlet bulkhead connectors: tubing: ID 4 mm max. pressure: 200 kPa (2 bar, 29 psi) Water inlet: tubing: ID 6 mm max. pressure: 50 kPa (0.5 bar, 7 psi) min. pressure: 30 kPa (0.3 bar, 4 psi) To/from condenser: To/from reactor: tubing: ID 6 mm tubing: ID 6 mm appiKorf DEPENDABLE INSTRUMENTS 1-7 USER MANUAL ADI 1035 Bio Console BASIC UNIT Version 3, November 1996 ENVIRONMENTAL CONDITIONS: The ADI 1035 Bio Console may be used at locations with the following environmental conditions: - Indoor use, Altitude: up to 2000 m, Temperature: 4°C to 45°C, Maximum relative humidity 80% for temperatures up to 31°C, decreasing linearly to 50% relative humidity at 45°C, Mains supply voltage: 115/230 Vac (+15%/-20%), 50/60Hz, Transient overvoltages according to INSTALLATION CATEGORIES II, POLLUTION DEGREE 2 in accordance with IEC 664, P-max=1600VA. appikorf DEPENDABLE INSTRUMENTS 1-8 USER MANUAL GAS SUPPLY ADI 1035 Bio Console Version 3, November 1996 CHAPTER 2 GAS SUPPLY 2.1 THE GAS SUPPLY UNIT: The ADI 1035 Gas Supply Unit supports four rotameter assemblies and a gas selection block: A = Gas selection valves .!__ . lAL.—..-_ ™ *v^ ~i*~ J J ^ ^ ™ The optional gas selection block contains four gas selection valves. With the gas selection valves, the application ("sparging" or "overlay") of the gas is selected. Note: - The upper gas inlet connector corresponds with the left hand rotameter assembly and the upper gas selection valve/bulkhead connector for gas outlet. Ordering number of the gas selection block: Ordering number of gas outlet bulkhead connectors: On next page, the available rotameter assemblies are listed. appiikorf DEPENDABLE INSTRUMENTS Z311302020 Z311302060 2-1 USER MANUAL GAS SUPPLY ADI 1035 Bio Console Version 3, November 1996 Available rotameter assemblies: Z3RM000005 Rotameter assembly Z3RM000010 Rotameter assembly Z3RM000020 Rotameter assembly Z3RM000030 Rotameter assembly Z3RM000040 Rotameter assembly Z3RMOOOO5O Rotameter assembly Z3RM000060 Rotameter assembly Z3RM000070 Rotameter assembly Z3RMOOOO8O Rotameter assembly 2.5 - 25 ml/min, 5.0 - 50 ml/min, 9.0 - 90 ml/min, 27 - 270 ml/min, 50 - 500 ml/min, 0.1 - 1.0 1/min, 0.5 - 5.0 1/min, 1.0 - 10 1/min, 2.3 -23 1/min. Rotameter assemblies can be applied with or without a Valve Module: B A - - C A = Rotameter B = Elbow C = Non return valve D D = Bracket E = Gas in F = Gas to reactor Rotameter Assembly A + C = Male connector h A B Ill I C D ;K B = Tubing D = Solenoid valve E = Mounting material 1 "J I"J• _1. G = Gas in =:__F -*-G F = Gas to reactor Rotameter Assembly with Valve Module appiikorf DEPENDABLE INSTRUMENTS 2-2 USER MANUAL GAS SUPPLY ADI 1035 Bio Console Version 3, November 1996 The Valve Modules are available in two versions: Z311302040 Valve Module for Rotameter Ass., 220 - 240 Vac, Z311302045 Valve Module for Rotameter Ass., 110 - 120 Vac. CAUTION: IF OXYGEN IS ONE OF THE SUPPLIED GASSES, VERIFY THAT THE CONNECTIONS AND TUBING INSIDE THE ADI 1035 ARE FREE OF LEAKS! Note: - The rotameter valves can be switched by outputs 4 through 7 of the ADI 1030 Bio Controler; see chapter 1.4 of this manual: Installation. appikorf DEPENDABLE INSTRUMENTS 2-3 USER MANUAL TEMPERATURE CONTROL ADI 1035 Bio Console Version 3, November 1998 CHAPTER 3 TEMPERATURE CONTROL 3.1 TEMPERATURE CONTROL SECTION: A = Power-on indication B = Max. loop temp, indication C = Cooling indication D = Heating indication E = Socket for heating blanket F = Power fuse G = Max. loop temp, adjustment H = Power on/off and fill switch FUSE RATING: 220-240 Vac: T3.15A, 110- 120 Vac: T 6.3A. Applied fuses must comply with IEC 127! The temperature control section supports heating/cooling in several ways: In the Basic Lay-Out, an actuator output signal for heating (output 8 from ADI 1030) is connected to the wall socket in the temperature control section. Heating blankets can be applied for heating the bioreactor (single actuator temperature control). CAUTION! ELECTRICAL SHOCK HAZARD. WHEN THE HEATING ACTUATOR IS SWITCHED ON, MAIN VOLTAGE IS DIRECTLY CONNECTED TO THE SOCKET! MAXIMUM LOAD = 400 VA. Note: - In this case, the Max. Loop Temperature adjustment/indication and cooling indication are not in use. - With the power switch in the middle (Fill) position, the temperature control module is in operation. appikorf DEPENDABLE INSTRUMENTS 3-1 USER MANUAL ADI 1035 Bio console TEMPERATURE CONTROL Version 3, November 1998 With an additional Cold Water Valve that can be installed in the ADI 1035, dual actuator temperature control can be obtained (heating and cooling). The actuator output signal for cooling (output 9 from ADI 1030) is directed to the Cold Water Valve. Note: - In this case, the Max. Loop Temperature adjustment/indication is not in use. - With the power switch in the middle (Fill) position, the temperature control module is in operation. An other way for dual temperature control is installing the Thermo Circulator Module for the ADI 1035. In this way the temperature is controlled by circulating heating/cooling water. Note: - In this case, the wall socket is not in use. In case the thermo-circulator module or the cold water valve is used or cooling water is required for the condenser, tap water supply must be connected (upper brass bulkhead connector at left hand side of ADI 1035); inlet pressure: 30 - 50 kPa (0.3 - 0.5 bar, 4 - 7 psi). A water pressure reducer is available as an option (see drawing D1018-la.12.005, art. nbr. Z310180050). The lower brass bulkhead connector is used for drain purposes, the middle bulkhead connector is used as vent (air from the circulation system). Below, the ordering information for all applicable hardware is listed: Z310180030 Z310180040 Thermo-circulator module 230 Vac, ADI 1035, Thermo-circulator module 110 - 120 Vac, ADI 1035. Z31O18OO6O Cold water valve module 230 Vac, ADI 1035, Z310180070 Cold water valve module 110 - 120 Vac, ADI 1035. Z31018005 0 Water pressure reducer for ADI 1018. Z311020022 Silicone heating blanket, 2 liter reactor, 230 Vac, Z311020030 Silicone heating blanket, 3 liter reactor, 230 Vac, Z311020050 Silicone heating blanket, 5 liter reactor, 230 Vac, Z311020070 Silicone heating blanket, 7 liter reactor, 230 Vac, Z311020150 Silicone heating blanket, 15/20 liter reactor, 230 Vac. Note: - When no temperature control actuators are installed, the water-inlet connection can still be used for condenser-cooling; connect ID 6 mm tubing to the "To -" and "From Condenser" tubing (see also chapter 1.4: water supply). appiikorf DEPENDABLE INSTRUMENTS 3-2 USER MANUAL ADI 1035 Bio console TEMPERATURE CONTROL Version 3, November 1998 3.2 COLD WATER VALVE: When a Cold Water Valve is installed, it can be used as a cooling actuator. In this case, the controlling device (e.g. the ADI 1030 Bio Controller) directly activates this cooling valve; when the reactor temperature exceeds setpoint, a 115/23 0Vac signal will open the Cold Water Valve for cooling. Pressure range of cooling water: see previous chapter (3.1). Using this option, the middle (Fill) position of the power switch has no function (temperature module is in operation!) and the Max. Loop Temp, adjustment is not present. appiikorf DEPENDABLE INSTRUMENTS 3-3 USER MANUAL TEMPERATURE CONTROL ADI 1035 Bio Console Version 3, November 1998 3.3 THERMO CIRCULATOR MODULE: SCHEMATIC LAY-OUT: W— H K A = Heat Exchanger C = Non Return Valve E = Safety Valve G = Pressure Reducer I = To Reactor K = Drain B = Circulator Pump D = Vent Valve F = 2-Way Valve H = Water In J = From Reactor L = Vent Note: - The connections "To -" and "From Condenser" are not shown in this lay-out. • The Heat Exchanger contains a Thermo Element and a Thermo Switch that will switch off the Thermo Element when the Maximum Loop Temperature is reached. CAUTION: THE CERAMIC BEARING OF THE CIRCULATOR PUMP WILL BE DAMAGED WHEN IT IS RUN DRY. applikort DEPENDABLE INSTRUMENTS 3-4 USER MANUAL ADI 1035 Bio console TEMPERATURE CONTROL Version 3, November 1998 The Circulator Pump is activated as soon as the power is switched on (lever in upper position). The controlling device (e.g. an ADI 1030 Bio Controller) can activate the heating actuator (thermo element) or the cooling actuator (2-way valve is opened: circulation water flows to the drain and cooling water is introduced into the system). The vent valve is a gas permeatic valve that will remove air/gas bubbles from the circulation system. The safety valve is a relief valve that opens at an internal pressure of approx. 100 kPa (1 bar, 14 psi); in this case, the circulation water flows to the drain until the pressure is reduced. USING THE THERMO CIRCULATOR: The Thermo Circulator Module for the ADI 1035 can be put in operation by following the steps that are listed below: - Connect the ADI 1035 Thermo Circulation System to the heat exchanger or jacket of the reactor using ID 6 mm tubing (use hose clamps to secure the tubing). The "To Reactor" tube-nipple contains a non-return valve; the "From Reactor" tube-nipple is a straight union. - Connect tubing (ID = 6 mm) to the Drain and Air Vent connector in order to lead any water or air to an open drain. - Connect the Mains cable to the wall socket. - Connect the water supply with max. inlet pressure of 500 kPa (= 0.5 bar, 7 psi) to the water inlet using ID = 6 mm tubing (use hose clamps to secure the tubing). Water is now introduced into the circulation system; air leaves the system through the Vent Valve. - The filling speed of the circulation system is increased by putting the Power-On switch in the middle (Fill) position; as a result, the 2-way valve is opened and water will eventually flow to the drain. When the circulation system is sufficiently filled, put the Power switch again in the lower (Off) position. - When the circulation system is filled, put the Power switch in the upper (On) position. As a result, the circulation pump is started. Any remaining air bubbles will leave the system through the Vent Valve. cippikorf DEPENDABLE INSTRUMENTS 3 5 USER MANUAL ADI 1035 Bio console TEMPERATURE CONTROL Version 3, November 1998 If the circulation pump is noisy, it means that there are still air bubbles present in the pump; return to the filling mode for approx. 15 seconds. Adjust the Max. Loop Temperature in such a way, that no "hot-spots" can occur in the reactor. Decreasing the Max. Loop Temperature setting will of course reduce the heating capacity of the Thermo Circulator. Note: The internal maximum loop temperature is approx. 95°C; the external maximum loop temperature is approximately 80°C. The ADI 1035 Thermo Circulator is now ready to be put in operation. MAINTENANCE: In case the maximum loop temperature is adjusted to a high value (> 80°C) and cooling water is frequently introduced into the system, lime scale accumulation may occur in the heating element resulting in reduced heat transfer. This lime scale sediment can be removed by circulating an EDTA solution (pH = 1 0 ) through the system, using the following procedure: - switch off the Thermo Circulator by switching the "on/off/fill" switch in the "off position and use hose clamps to close the tubes to and from the jacket / heat exchanger of the reactor. - in case of a jacketed reactor: remove the upper hose connector from the jacket move the reactor in such a way that the lower hose connector is positioned above a sink or bucket and remove the lower hose connector in order to drain the jacket - in case of a heat exchanger: remove both hose connectors from the heat exchanger - insert both disconnected hoses in a flask (beaker) containing a 0.1 Molar EDTA solution (pH =10) (for further details, see the recipe below) and remove both hose clamps. - start circulation of the EDTA solution by switching the "on/off/fill" switch in the "on" position; keep circulation going for several hours (depending on the amount of lime scale deposit). - switch the "on/off/fill" switch to the "off position. Insert the hose "from reactor" in a flask (beaker) with at least 1 liter of tap water. Direct the hose "to reactor" to the sink (drain or bucket) and switch the "on/off/fill" switch again to the "on" position. Rinse the Thermo Circulator with tap water. Make sure that the pump is switched off again before it runs dry. - use the hose clamps again to close both hoses; rinse the outside of both hoses with tap water to remove any left EDTA solution from its surface. The Thermo Circulator now again can be put to normal operation. Recipe for a 0.1 Molar EDTA (ethylene diamino terra acetic acid) solution with a pH of 10: - Dissolve 8 gram NaOH in a small amount of water (solution will be very hot!) - make it up to 1 liter - add 37.2 gram of EDTA (di-sodium salt), stir until all solids are dissolved - the solution is now ready to be used appiikorf DEPENDABLE INSTRUMENTS 3-6 USER MANUAL ADI 1035 Bio Console TEMPERATURE CONTROL Version 3, November 1998 WARNING: The EDTA solution is alkaline (pH = 10). Contact of this solution with skin, especially mucous membrane or eyes, must be avoided. If such contact occurs, the affected area must be thoroughly rinsed with water. appiikorf DEPENDABLE INSTRUMENTS •3 7 °' USER MANUAL STIRRER SPEED CONTROL ADI 1035 Bio Console Version 3, November 1996 CHAPTER 4 STIRRER SPEED CONTROL 4.1 STIRRER SPEED CONTROL: The ADI 1035 Bio Console can be equipped with two different stirrer speed controllers; one for the stirrer motors P100, P140 and P310, the other for the stirrer motor P1000. Stirrer speed control section: A B A = Power / overload indication B = Display stirrer speed (r.p.m.) C = Stirrer motor connection D = Local / remote switch E = Fuse for controller P100-310: T 1.6A/115Vac - T 0.8A/230Vac P1000: T6.3A/115Vac-T3.15A/230Vac F = Potentiometer manual speed G = Power on / off switch D Caution: - According to the European Community legislation on machinery, the stirrer motor is a machine with potential hazard. Refer to the stirrer motor user manual for safety instructions, fuse rating and functionality. - In case the stirrer speed controller for the P1000 motor is installed, the stirrer cable must not be disconnected while the power (H) is switched on; the voltage at the connectors may exceed 60Vdc so precaution must be taken to avoid risk of electric shock! The "On/Off tumbler switch is used to switch the stirrer speed controller on/off; the "power/overload" indicator will be green in case the power is switched on, in overload situations (maximum torque is reached) the indicator will become red. appiikorf DEPENDABLE INSTRUMENTS 4-1 USER MANUAL ADI 1035 Bio Console STIRRER SPEED CONTROL Version 3, November 1996 The liquid cristal display presents the current revolutions per minute. The "Local/Remote" tumbler switch is used for the selection of the stirrer speed controller function: "Local" = stirrer speed is set manually (potentiometer at front panel), "Remote" = stirrer speed is controlled by a remote 4 - 2 0 mA signal (e.g. from the ADI 1030 Bio Controller). The cable connection for the stirrer motor is located at the front panel; the cable connection for remote control by the ADI 1030 Bio Controller is located at the rear (sub-D connector). Ordering information for applicable hardware: Z510320030 Z510320040 Stirrer controller module P100 - P310, Stirrer controller module PI000, Z5100002M0 Z5100002M1 Z5100002M3 Z51 OOP 1000 Z510000001 Z510000002 Z51 OOP 1005 Stirrer motor assembly P100, Stirrer motor assembly P140, Stirrer motor assembly P310, Stirrer motor assembly P1000, Stirrer motor assembly P100 1=6, Stirrer motor assembly P140 1=2, Stirrer motor assembly PI000 1=5, Z510121C02 Cable for P100-P1000 ADI 1035, Z510120900 Control cable motor speed short (ADI 1030), Z510120000 Recalibration of stirrer speed controller (required calibration range must be specified). cippiikorr DEPENDABLE INSTRUMENTS 4-2 USER MANUAL LEVEL CONTROL ADI 1035 Bio Console Version 3, November 1996 CHAPTER 5 LEVEL CONTROL The Level Control option of the ADI 1035 Bio Console can be used to activate a pump on liquid contact with the level sensor; this option is used for both foam control and level control. Level control section: A = LED indication for pump 3 B = Tunnel for sensor cables C = Level sensor connection D = Power fuse E = On / off/ auto switch FUSE RATING: 230 Vac: T 1A, 110-120 Vac: T2A. Applied fuses must comply with IEC 127! With the tumbler switch in the: "on" position, pump 3 is activated continuously, "off position, pump 3 is stopped, "auto" position, pump 3 is activated when level contact is detected. The LED indicator shows the pump activity. Remark: When the level control module is installed, output 3 of the ADI 1030 can be used for general alarm indication (LED at the power section of the ADI 1035); also refer to chapter 7 (switch settings). When no level control module is installed, pump 3 can be used for other purposes (manual or remote control). appikorf DEPENDABLE INSTRUMENTS 5-1 USER MANUAL ADI 1035 Bio Console LEVEL CONTROL Version 3, November 1996 Ordering information for applicable hardware: Z510203095 Z510203096 Z71513 AF02 Level control module ADI 1035, 220 - 240 Vac, Level control module ADI 1035, 110 - 120 Vac, Cable for level sensor. appiikorf DEPENDABLE INSTRUMENTS 5-2 USER MANUAL PUMPS ADI 1035 Bio Console Version 3, November 1996 CHAPTER 6 PUMPS The Pump Section contains four positions for pumps: B A = Potentiometer for variable speed adjustment B = Position for variable speed drive C = On / off / remote switch for fixed speed drive 1, 2 and 3 D = Position for fixed speed drive 1, 2 and 3 At pump positions 1,2 and 3, fixed speed pump drives can be installed for manual or remote control operation (in case the level control module is installed, pump 3 is used for level control); each pump can be switched on/off/remote with a tumbler/toggle switch. At pump position 4, a variable speed pump drive can be installed for stand alone operation. appikorf DEPENDABLE INSTRUMENTS 6-1 USER MANUAL PUMPS ADI 1035 Bio Console Version 3, November 1996 Caution: Accordig to the European Community legislation on machinery, a pump drive is a machine with potential hazard. Only apply these drives with the pump heads and tubing that are described in this chapter! Do not use the tubing pump drives for other purposes than displacement of fluids (or gas). Switch off the power of the pump drive before replacing any tubes or pump heads! Application of damaged tubes may result in fluid leaking into the pump drive! Verify the tube quality inside the pump head before every fermentation run. The following two types of pump heads can be used on the available drives: •' FLOW DIRECTION M M DIRECTION Masterflex Easy-Load pump head Standard Masterflex pump head The variable speed pump drive has an internal fuse. Fuse rating: 250VacT0.8A. Applied fuses must comply with IEC 127! For ordering information of applicable hardware, see next page: appikorf DEPENDABLE INSTRUMENTS 6-2 USER MANUAL PUMPS ADI 1035 Bio Console Version 3, November 1996 Z311500010 Z311500011 Z311500020 Z311500021 Fixed Fixed Fixed Fixed speed drive 5 rpm, 230 Vac, ADI 1035, speed drive 6 rpm, 110 - 120 Vac, ADI 1035, speed drive 17 rpm, 230 Vac, ADI 1035, speed drive 20 rpm, 110 - 120 Vac, ADI 1035, Z311600010 Z311600011 Variable speed drive 10 - 120 rpm, 230 Vac, ADI 1035, Variable speed drive 10- 120 rpm, 110 - 120 Vac, ADI 1035, Z311500005 Blind plate for unused pump position, Z375180000 Z375180200 Easy-load pump head for thin wall tubing, Easy-load pump head for thick wall tubing, Z370132000 Z370142000 Z370152000 Z370162000 Z370182000 Standard pump head 7013-20, Standard pump head 7014-20, Standard pump head 7015-20, Standard pump head 7016-20, Standard pump head 7018-20. Available tubing material: Two types of tubing can be used for hydraulic and gaseous connections: Silicone tubing: inert and transparent material Norprene Food tubing: physically inert material, especially useful for tubing pumps (long lifetime) and aeration purposes (less gas permeable than silicone) Z364111300 Z364111400 Z364111500 Z364111600 Z364111800 Z364021300 Z364021400 Z364021500 Z364021600 Z364021800 Silicone tubing, 7.5 m, ID = 0.8 mm, for hose barb of 1.6 mm (1/16") (thin-wall tubing, used in pump head 7013) Silicone tubing, 7.5 m, ID = 1.6 mm, for hose barb of 1.6 mm (1/16") (thin-wall tubing, used in pump head 7014) Silicone tubing, 7.5 m, ID = 4.8 mm, for hose barb of 4.8 mm (3/16") (thick-wall tubing, used in pump head 7015) Silicone tubing, 7.5 m, ID = 3.1 mm, for hose barb of 3.2 mm (1/8") (thin-wall tubing, used in pump head 7016) Silicone tubing, 7.5 m, ID = 7.9 mm, for hose barb of 9.5 mm (3/8") (thin-wall tubing, used in pump head 7018) Norprene food tubing, 7.5 m, ID = 0.8 mm, for hose barb of 1.6 mm (1/16") (thin-wall tubing, used in pump head 7013)) Norprene food tubing, 7.5 m, ID = 1.6 mm, for hose barb of 1.6 mm (1/16") (thin-wall tubing, used in pump head 7014)) Norprene food tubing, 7.5 m, ID = 4.8 mm, for hose barb of 4.8 mm (3/16") (thick-wall tubing, used in pump head 7015)) Norprene food tubing, 7.5 m, ID = 3.1 mm, for hose barb of 3.2 mm (1/8") (thin-wall tubing, used in pump head 7016)) Norprene food tubing, 7.5 m, ID = 7.9 mm, for hose barb of 9.5 mm (3/8") (thin-wall tubing, used in pump head 7018) appiikorf DEPENDABLE INSTRUMENTS 6-3 USER MANUAL JUMPERS ADI 1035 Bio Console Version 3, November 1996 CHAPTER 7 JUMPERS Additional to the assembling information that is listed on the supplied drawings (see chapter 8 of the English copy of this user manual), SI, S2 and S3 on the ADI 1035 Control Board (located just below the Seperation Plate) must be properly jumpered: - SI: No-Therm. Circ. / Therm. Circ. - S2: Internal/External (mains of control signals) - S3: No-Level Detector / Level Detector LEDS 0 © © 0 o N CXI. 5:1 0 0 LUI, CDOUNCH 1 1 o UMG I a 0 xn ADI 1035 Control Board Default -SI: - S2: - S3: setting of the board: No-Therm. Circ. Internal No Level Detector appiikorf DEPENDABLE INSTRUMENTS 7-1 USER MANUAL JUMPERS ADI 1035 Bio Console Version 3, November 1996 7.1 THERMO CIRCULATOR: In case the Thermo Circulator Module Z31018003/40 is installed, S1 must be jumpered like: S1 9 5f £ I I NO THERM.CIRC./THERM.CIRC. Connector X27 must be removed from X2 on Central Control Board and be connected to X2 on the Controller Board of the Thermo Circulator. Connector X28 must be removed from XI on Central Control Board and be connected to XI on the Controller Board of the Thermo Circulator. The external Heating Control signal must be supplied at the Remote Control Connector pin 8. The external Cooling Control signal must be supplied at the Remote Control Connector pin 9. See also 7.4. 7.2 MAINS SUPPLY CONTROLLING DEVICE: If the power supply cable(s) of the controlling device (e.g. the ADI 1030 Bio Controller) are connected to the MAINS SUPPLY CONNECTORS FOR ADI 1030, S2 must be jumpered as default. Caution: If the power supply cable(s) of the controlling device (e.g. the AD11030 Bio Controller) are not connected to the MAINS SUPPLY CONNECTORS FOR ADI 1030 but have their own power source, S2 must be jumpered like: The external mains must be connected to the remote control connector at the rear of the ADI 1035 (live = pin-11, neutral = pin12). Refer to 7.4. The switched power sockets have a total maximum load of 250 W. appiKorf DEPENDABLE INSTRUMENTS S2 • 0• 0• n U • D ho en - j oo CO S! ho 7-2 USER MANUAL JUMPERS ADI 1035 Bio Console Version 3, November 1996 7.3 LEVEL DETECTOR: In case a Level Detector is installed (on X14, inner rear side), S3 must be jumpered like: S3 CJDCJD NO LEVEL DET./LEVEL OET. Actuator for level detection: pump 3 (pump status must be: remote operation). In this case, pin 3 of the remote control connector (rear of ADI 1035) can be used for general alarm indication of the controller (LED indication at the power section of the ADI 1035). If "No Level Detector" is selected, pump 3 can either be used by manual or remote control. 7.4 REMOTE CONTROL CONNECTOR: REMOTE CONTROL 0 The 12-pins remote control connector at the rear of the ADI 1035 Bio Console has the following lay-out: 12 3 4 5 6 7 8 9101112 DDDDDDDDDDDD Remote Control Pin-nbr. Function 1 Pump 1 2 Pump 2 3 Pump 3 or Alarm 4 Rotameter Valve 1 5 Rotameter Valve 2 6 Rotameter Valve 3 7 Rotameter Valve 4 8 Heating Element 9 Cooling Element 10 Alarm 11 External Live 12 External Neutral 0 Note: In case the ADI 1030 Bio Controller is used to generate the remote control signals, the standard control cable must be equipped with a ferrite bead (connected around the cable). Location of the ferrite bead: near the ADI 1030. The ferrite bead comes with the ADI 1030. appiikorf DEPENDABLE INSTRUMENTS 7-3 USER MANUAL DRAWINGS ADI 1035 Bio Console Version 3, November 1996 CHAPTER 8 DRAWINGS The following drawings are enclosed: D1035-3d.12.101 D1035-lb.12.002 D1035-lc.12.020 D1035-1 .12.202 D1035-la.12.206 D1018-2c.12.003 D1018-la.12.005 D1035-lc.12.106 D1020-lb. 12.309 D1035-le.12.110 D1035-ld.12.220 D1035-1 .12.000 Bio console basic 110 - 240V ADI 1035 Rotameter assembly Valve for rotameter Basic gas selection block Gas outlet bulkhead connector set Thermo circulator module 110 - 220V ADI 1035 Water Press. Reducer for ADI 1018 Cold water valve 115/230VADI1035 Level Control 110 - 240V ADI 1035 Fixed speed drive 5/20 rpm ADI 1035 Var. speed drive 10 - 120 rpm ADI 1035 Blind plate for pump position ADI 1035 appiikorf DEPENDABLE INSTRUMENTS 8-1 GAS SUPPLY UNIT GAS SELECTION POWER SECTION REMOTE CONTROL CONNECTOR MAINS SUPPLY CONNECTORS FOR ADI1030 STIRRER SPEED CONTROL• CONNECTOR MASS FLOW CONTROL• CONNECTORS STIRRER SPEED CONTROL GAS INLET CONNECTIONS Pmox: 2bar © LEVEL CONTROL ;H iff TEMPERATURE CONTROL © 18 © o o o zz. © to o «§ PUMP POSITION FIXED SPEED TUBING CONNECTIONS CONDENSER CO CO CO PUMP POSITION VARIABLE SPEED o © © WATER - INLET Pmax: 0.5bar ® TUBING CONNECTIONS REACTOR MAINS INLET © ® ® © DRAIN o CABLE • AIR VENT 3 3 I p. o PUMP POSITION FIXED SPEED PUMP POSITION FIXED SPEED en DIMENSIONS W x H x D : 400 mm x 630 mm x 370 mm REAR VIEW A ELBOW ROTAMETERNON RETURN VALVE TO GAS SELECTION UNIT IS LO CM BRACKET GAS IN \l Rotameter Rotameter Rotameter Rotameter Rotameter Rotameter Rotameter Rotameter Rotameter Rotameter Rotameter ass, app 2.5 - 25 ml/min. ass, app 5 - 5 0 ml/min. ass, app. 9 - 9 0 ml/min. ass, app. 27 - 270 ml/min. ass, app. 50 - 500 ml/min. ass, app 0.1 - 1.1 l/min. ass, app. 0.5 - 5 l/min. ass, app. 1 . 0 - 1 0 l/min. ass, app. 2.3 - 23 l/min. ass, app. 4.3 - 43 l/min. ass, app. 6.0 - 60 l/min. PVe REV. DRAWN PROJECTION : DRAWING NAME Z3RM000005 Z3RM000010 Z3RM000020 Z3RM000030 Z3RM000040 Z3RM000050 Z3RM000060 Z3RM000070 Z3RM000080 Z3RM000090 Z3RM000100 12 sep. 1996 12 sep.96 MVo REVISION REVISION DATE ROTAMETER ASSEMBLY PART NBR.: lOapplikorf SCAl£ DESIGNED ^ ^ 1 ^ DEPENDABLE INSTRUMENTS CHECKED DRAWING SEE ABOVE D1035-1b.12.002 NBR. : 1 SHEET: 1 OF 1 09 mar. 1992 MVo 09 mar. 1992 MVo _ 1996 Appllcon Dependable Instruments B.V. No part of mis drawng may be copied or reproduced in any form or by any means or transferred to any third party without we prior written consent of Appl&on Dependable Instruments B.V. A.D.I. B.V. E3P.O. BOX 149 CHECKED 3100 AC SCHIEDAM HOLLAND ©(31)10-4621855 DIMENSIONS ARE IN mm FAX (31)10-4379648 SZE : A4 ELBOW MALE CONNECTOR TUBING BRACKET MALE CONNECTOR SOLENOID VALVE NON RETURN VALVE CABLE FEMALE CONNECTOR MOUNTING MATERIAL TO BIOREACTOR GAS IN PLACE NON RETURN VALVE AND FEMALE CONNECTOR BELOW THE SOLENOID VALVE Valve rotameter 0 - 2 3 l/min. 230Vac Valve rotameter 0 - 2 3 l/min. 115Vac Z311302040 Z311302045 12 sep. 199612 sep.96 MVo PVe REV. DRAWN PROJECTION : DRAWING NAME REVISION DATE REVISION VALVE FOR ROTAMETER PART NBR.: toappiikorf SCALE DESIGNED ^ ^ 1 ^ DEPENDABLE INSTRUMENTS CHECKED DRAWING 1 20 may 1992 20 may 1992 NBR. : D1035-1c.12.020 MVo MVo © 1996 Applikon Dependable Instruments B.V. No part of this drawing may be copied or reproduced in any form or by any means or transferred to any third party without the prior written consent of Appltkon Dependable Instruments B.V. A.D.I. B.V. CHECKED BOX 149 3100 AC SCHIEDAM HOLLAND @ (31)10-4621855 APPR.:, SHEET: 1 OF DIMENSIONS ARE IN mm FAX (31)10-4379648 SIZE: A4 GAS SELECTION BLOCK GAS SELECTION VALVES — GAS INLET 1/4" TUBING CONNECTOR (4x) GAS OUTLET 1/4" TUBING CONNECTOR (2x) J> DESCRIPTION MATERIAL OR TYPE REMARKS PROA, BASIC GAS SELECTION BLOCK e Z311302020 applikorY DEPENDABLE INSTRUMENTS _pv DATE 16- DRAWING NO.: D1035-1 .12.202 SCALE 12-1992 SHEET T DIMENSIONS IN mm OF 1 I FORM: A 3 C !99%oolikon Dependable Instruments B.V No D^M ol thia drawing may be coo*ed or reproduceo >n any torn} of ay any means of transferee to any third party without the prior written consent of Applikon Oepondaole Instruments B.V. APPUKON DEPENDABLE INSTRUMENTS BV SCHIEOAM-MOLLAND I V < ] P O B 149 « © w 010 - 4 6 2 !8 55 FAX 0 1 0 • 4 3 7 9 6 4 8 i\ o o o <p> L_ BULKHEAD CONNECTOR! GAS OUT' xswe i O O O (®) .GAS IN a PVe PARTS LIST CHANGED. REV. DRAWN DRAWING NAME : ^ ^ REVISION DATE PART NBR.: DRAWING SCALE NBR. : DESIGNED DEPENDABLE INSTRUMENTS CHECKED 21 jan. 1993 PVe 22 jan. 1993 MVo 1994 Applikon Dependable Instruments B.V. lo part of this drawing may be copied or reproduced in any form or by any means or transferred to any third party without the prior written consent of Applikon Dependable Instruments B.V. A.D.I. B.V. 0 P . O . BOX 149 CHECKED GAS OUTLET BULKHEAD CONNECTOR SET Z311302060 D1035-1a.12.206 1 IQappiikorT ^ 20 jun. 199421 [un.94 MVo REVISION 3100 AC SCHIEDAM HOLLAND ©(31)10-4621855 SHEET: 1 OF DIMENSIONS ARE IN mm FAX (31)10-4379648 SIZE : A4 SECTION B - B WITH POSITION OF THERMO SWITCH WATER INLET • • CONNECTIONS : A - A / INLET ADM 018 - PUMP IN. DRAIN B-B / PUMP OUT - HEATER IN. C-C / HEATER OUT - TO REACTOR. D-D / FROM REACTOR - AIR RELIEF VALVE. AIR VENT E-E / PRESSURE RELIEF VALVE - WATER OUT. F-F / AIR RELIEF VALVE - AIR RELIEF OUT. G-G / V-JUNCTION - DRAIN. H-H / WATER INLET - INLET ADI1018. l-l / FROM CONDENSOR - V-JUNCTION. J - J / WATER INLET - TO CONDENSOR REGULATOR. K-K / FROM CONDENSOR REGULATOR - TO CONOENSOR. SECTION A - A WITH DETAIL OF THERMO SWITCH POSITION OF PASSAGE THROUGH SEPARATION PLATE OF WIRE THERMOSTAT SWITCH. ELBOW, V-DISTR. AND MALE ADAPTOR UNION COME WITH ADI1035. APPLY OMNIFIT SEAL 50H WHEN INSTALLING THE MODULE. DETAIL OF PROTECTION PLATE DESCRIPTION ART. NR. THERMO CIRCULATOR MODULE 1l0-120Vac ADI1035 Z31B180040 THERMO CIRCULATOR MODULE 220-240Voc ADI1035 Z310180030 CONNECTIONS OF ADI1035 WIRING TO ADI1018 MODULE: X23 X24 X25 X26 X27 X28 X29 ON X8 MAINS IN ON X10 "OFF/FILL/ON" SWITCH ON X3 "THERMOSTATE" SWITCH ON X9 CONTROL ON X1 FOR "MAX. LOOP TEMP./HEATING" LEDS ON X2 FOR "COOLING/POWER ON" LEDS ON THERMO SWITCH : WH - 11 BR - 12 GN - 14 (X27 AND X28 ARE MOUNTED ON CENTRAL CONTROL BOARD ADI1035) SWITCH SI ON CENTRAL CONTROL BOARD ADI1035 TO "THERM. CIRC." c iRHu 27 nov. 1995|27 nov. 9 5 RCI THERM.CIRC.MODULE 110-240Vac ADI1035 SEE SHEET D1018-2c.12.003 12 oct. 1993 PVe 13 oct. 1993 MVo SHEET: 1 Of ikon Dependoble Instruments B.V. meonj or transferred a drawing may be copied or reproduced in oay larm o by on/ m ndoble Insi AC SCHOAU HOUAND ?(3OI0-462.BU FAX (31)18-4379648 SIZI : A2 2 I CD 1 © 5^3 o Us M o o 5-3 I TO REACTOR n 1*1 o o o o5 5 I O .3* L§ >^ CO co OJ i S. CO CO OJ -o cf < t o oo I ro o 3 to o o cz VALVE NON-RETURN V MAX. 0.5 bar VALVE SAFETY (1 bar) OJ oo VALVE 2-WAY DRAIN Si en i TO ATMOSPHERIC DRAIN > o i NO OJ o en OJ WATER INLET VALVE AIR REUEF U CO CO O VALVE NON-RETURN oo I ro ro rO i m I PUMP i CO o FROM REACTOR 3 O m m co HEAT EXCHANGER AIR VENT TO ATMOSPHERIC DRAIN oo SI co en o o OJ Si LEGEND : ( T E ) THERMO ELEMENT TS) THERMO SWITCH WATER REGULATOR Pressure adjustment knob 1 WATER IN Pmax:25bar (362.6psi,2500kPa) WATER OUT Pmax:0.5bar (7.3psi,50kPa) CONNECTION 8mm POS. QTY. CONNECTION 8mm DESCRIPTION MATERIAL OR TYPE WATER PRESS. REDUCER FOR ADI1018 PART NO. I D applikon' ^ % | ^ ^ D E P E N D A B L E INSTRUMENTS SCALE DESIGN. Z31 01 80050 1 MVo REMARKS PRO), CHECKED: DRAWING NO.: 1 11018-10.12.005 DATE 18-02- MOD. Q I 11 0 4 9 4 I DIMENSIONS IN mm | FORM: A 4~ 1 OF © 1MM'* Applikon Dependable Instruments B.V. No part of this drawing may be copied or reproduced in any form or by any means or transferred to any third party without the prior written consent of Applikon Dependable Instruments B.V. APPLIKON DEPENDABLE INSTRUMENTS BV SCHIEDAM-HOLLAND P.O.B. 149 > 010 - 4 6 2 1 8 5 5 FAX 010 - 437 9648 MOUNTING SCREW M4x8 (4x) =======:=:=:===:=:===:=:=:==:=====:=: ""•« Cl HOSE CONNECTOR O.D.6 'I II II II II II II II II HOSE CLAMP V-DISTRIBUTOR UNION j! n n,,n..n ,i111111ii 111 II I I I ! Ml II I il I 11 I I I I I I I I '[junuiju ====:===:== VALVE ELBOW (FRONT PLATE IS REMOVED) DESCRIPTION ART. NR. COLD WATER VALVE MOD. 115Vac COLD WATER VALVE MOD. 230Vac c PVe REV. toapplikorf • ^ REVISION DATE ON SHEET 2.5 SCALE DESIGNED DEPENDABLE INSTRUMENTS CHECKED DRAWING NBR. : 11 dec. 1992 11 dec. 1992 D1035-1c.12.106 MVo MVo © 1994 Apptikon Dependable Instruments B.V. No part of this drawing may be copied or reproduced in any form or by any means or transferred to ony third party without the prior written consent of Appltkon Dependable Instruments B.V. A.D.I. B.V. 0 P . O . BOX 149 CHECKED COLD WATER VALVE 115/230Vac ADI1035 PART NBR.: ^ 2310180070 Z310180060 15 nov. 1994 15 nov.94 MVo REVISION DRAWN PROJECTION : DRAWING NAME ADI1035 ADI1035 3100 AC SCHIEDAM HOLLAND "©(31)10-4621855 SHEET: 1 Of SIZE : A3 DIMENSIONS ARE IN mm FAX (31)10-4379648 INNER VIEW REAR PLATE "iTT ffi n to to n ^totoP \ ^ ' f \ ^ > / SOCKET LEVEL RELAY LOCK SPRING LEVEL CONTROL 220-240V AD11035 LEVEL CONTROL 110-120V ADI1035 Z510203095 Z510203096 b RHu RELAY CHANGED. REV. 31 auq, 1995 31 auq,95 RCI REVISION DRAWI PROJECTION : DRAWING NAME : REVISION DATE LEVEL CONTROL PART NBR.; toappiikorf ^•^DEPENDABIX SCALE DESIGNED INSTRUMENTS CHECKED 110-240V ADI1035 DRAWING D1020-1b.12.309 NBR. : 1 : 2 27 jan. 1993 RHu 27 Jan. 1993 RCI © I99S Applikon Dependable Instruments B.V. No part of this drawing may be copied or reproduced in any form or by any means or transferred to ony third party without the prior written consent of Applikon Dependable Instruments B.V. A.D.I. 8.V. EJP.O. BOX 149 3100 AC SCHIEDAM HOLLAND CHECKED ©(31)10-4621855 APPR.: SHEET: 1 OF SIZE : A3 DIMENSIONS ARE IN mm FAX (31)10-4379648 FRONT VIEW o o oo • era RIGHT SIDE VIEW A FRONT PLATE OF ADI 1035 NYLON SPACER 10x10mm (1x) NYLON SPACER 3x10mm (2x) @® D o o oo Bio Console ' ADI 1035 >|< = POSITION FOR FIXED SPEED DRIVE ' Z311500010 Z311500011 Z311500020 Z311500021 FIXED FIXED FIXED FIXED SPEED SPEED SPEED SPEED DRIVE 5RPM DRIVE 6RPM DRIVE 17RPM DRIVE 20RPM ' 230V 115V 230V 115V DKo REV. 23 Jan. 1997 23 Jan. 97 HMo REVISION DRAWN PROJECTION DRAMNG NAME REVISION DATE • FIXED SP. DRIVE 5/20RPM ADI1035 DRAWING tOapplikorT ^ • ^ SCALE DESIGNED DEPENDABLE INSTRUMENTS CHECKED NBR. : D1035-1e.12.110 14 oct. 1992 AvS 14 oct. 1992 RCI © 1997 Appllkon Dependable Instruments B.V. No port of this drawing may be copied or reproduced in ony form or by any means or transferred to ony third porty without the prior written consent ol Applfron Dependable Instruments B.V. A.D.I. B.V. JE3P.O. BOX 149 CHECKED 3100 AC SCHIEDAM HOLLAND ©(31)10-4621855 SHEET: 1 OF SIZE : A3 DIMENSIONS ARE IN mm FAX (31)10-4379648 230V LEFT SIDE VIEW FRONT VIEW NUT AND NYLON RING KNOB DRIVECONNECTOR 115V LEFT SIDE VIEW FRONT PLATE OF ADI 1035 _ . WET PART SEPARATION PLATE NYLON SPACER 10x10 (1x) SCREW M4 NYLON SPACER 3x10 (2x) NUT AND NYLON RING KNOB DRIVECONNECTOR = POSITION FOR VAR. SPEED DRIVE Z311600010 Z311600011 VAR. SP. DRIVE 10-120RPM 230V VAR. SP. DRIVE 10-120RPM 115V d DKo REV. DRAWN PROJECTION DRAWING NAME : 23 jon. 1997 23 jon. 97 Htvtc REVISION REVISION DATE CHECKED VAR. SP. DRIVE 10-120RPM ADI1035 7NGD1035-1d.12.220 PART NBR.; SCALE DESIGNED DEPENDABLE INSTRUMENTS CHECKED 14 oct. 1992 14 oct. 1992 MVo RCI © 1997 Applikon Dependable Instruments B.V. No port of this drawing may be copied or reproduced in any form or by any means or transferred to ony third party without the prior written consent of Applikon Dependable Instruments B.V. A.D.I. B.V. E3P-O. BOX 149 3100 AC SCHIEDAM HOLLAND ©(31)10-4621855 SHEET: 1 OF DIMENSIONS ARE IN mm FAX (31)10-4379648 SIZE : A3 POS. QTY. MATERIAL OR TYPE DESCRIPTION BUNDPLATE PUMP POSITION AD11035 1 IDapplikon PART NO. SCALE DESIGN. ^ ^ I ^ D E P E N D A B L E INSTRUMENTS Z311500005 DATE PV 16- 12-1992 MOD. REMARKS PROJ./ DRAWING NO.: D1035-1 .12. SHEET 1 DIMENSIONS IN mm OF 1 FORM: A 4 © 1992 Applikon Dependable Instruments B.V. No part of this drawing may be copied or reproduced in any form or by any means or transferred to any third party without the prior written consent of Applikon Dependable Instruments B.V. APPLIKON DEPENDABLE INSTRUMENTS BV SCHIEDAM-HOLLAND P.O.B. 149 )O10-4621855 FAX 0 1 0 - 4 3 7 9 6 4 8 G:\Eng\fermentorcontrollers\MFCS gebouw 4\39-Applikon-de IQVApplicon 1030-1035 fermentor controller IQ.doc. Page 1 of 5 . 3/11/03 11:51 AM Description of Bioconsole 1035 and Biocontroller 1030 controller commissioning. Connect all wiring , water supply and water drain and all gas supply lines. Then proceed as mentioned below. 1 Ensure 4 medical gas supplies of Air, N2, 02 and C02 are present. 4 valves on wall must be opened. 2 Ensure 4 medical gasses are present at pressure regulating box. Output pressure must be set to 0.5 Bar. See various manometers. 3 All four gasses must enter the 1035 bioconsole at their designed entrances. Verify the identity of the gasses. 4 Connect water with a pressure of 0.5 Bar to the water inlet on the side of the Bioconsole 1035. Make sure the valve under the table is opened. Tighten all waterconnections very well. 5 Connect the water drain to the side of the Bioconsole 1035. 6 Connect the 1030 controller to the 1035 controller with four cables jf ' 6.1 The green 230V connector with 9 core wire. -~T 6.2 The 230V mains connector from "power switched " 1035 to The central point at the rear of the 1030 controller unit. 6.3 The Analoge signal wiring from the top analogue output to thel 035 bioconsole stirrer input. 4..20mA 6.4 The analogue signal wiring from the bottom analogue output to the 1035 bioconsole MFC2 input. 4..20 mA Connect the 230 V of the 1035 Bioconsole and the 230V of the 1030 controller to the output of a dedicated Ups. 8 Connect the 1030 controller to the MFCS server. 9 Configure the MFCS server .£ Q/uf't r e MFCS-configuration menu ' r f Com Description Protocol NT Protocol Device 1 2 3 4 Defective PK-2900 IFX box PK-0600 RS232 RS232 RS232 RS232 RS422 RS232 — ^^ )C # » Network identity 2 1,4,5,6,7 3 Baud rate 9600 9600 9600 -V\ K Fr parity Even Even Even Data bits 7 7 7 stop bits 1 1 1 G:\Eng\fermentorcontrollers\MFCS gebouw 4\39-Applikon-de IQ\Applicon 1030-1035 fermentor controller IQ.doc. Page 2 of 5 . 3/11/03 11:51 AM Run-Operations-Group-Select controller-Verify that all online parameters are active. 10 Verifying electrical connections: 10.1 Press Main menu 1030 10.2 Press Utility 10.3 Press Verify 7 10.4 Press output 7 10.5 Press Analogue 10.6 Select out put 1 10.7 Select Edit and give setpoint 0% and setpoint 100% 10.8 Upper analogue output 1 of AD11030 must now change from 4 to 20 mA. Verify with external multimeter. 7 Y Highvalue=...mA 2.C0O ll-oo LowValue=....mA 10.9 , v roo% A c f yu Select out put 2 10.10 Select Edit and give setpoint 0% and setpoint 100% 10.11 Lower analogue output 12of AD11030 must now change from 10.12 4 to 20 mA. Verify with external multimeter. Highvalue=...mA XO-OO / 2 . OQ LowValue=....mA 10.13 Press Main menu 1030 10.14 Press Utility 10.15 Press Verify 10.16 Press output ^ r >& /0 G:\Eng\fermentorcontrollers\MFCS gebouw 4\39-Applikon-de IQ\Applicon 1030-1035 fermentor controller IQ.doc. Page 3 of 5 . 3/11/03 11:51 AM 10.17 Press Digital Select out put 1 10.18 Switch on main switch of Bioconsole 1035. 10.19 Switch on main switch of Bioconsole stirrer controller. 10.20 Set switch of stirrer controller to local and verify that external motor can range in speed from 0 to 1200 rpm. Low....rpm. 0 High....rpm 10.21 Set switch of stirrer controller to remote. 10.22 Switch on and of output with F5 on the biostat controller 1030. 10.23 Test the following inputs 10.22.1 Output 1 Pump 1. Set pumpswitch to remote. 10.22.2 Output 2 Pump 2. Set pumpswitch to remote. 10.22.3 Output 3 Pump 3. Set pumpswitch to remote. ,, ---7 Leave overlay (headspace) and sparger outputs on front Biostat console 1035 unobstructed. 10.22.4 Output 6 0 2 Valve.The indicatorball moves up to 10.22.5 Output 7 CO2 Valve. The indicator ball moves up to f ml/min ml/min Connect transparent tubing to reactor to and from connections and switch heating circuitry to fill until no airbubbles are visible within the external tube. 10.22.6 Output 8 Heating of vessel. Does the reactor tube heat up and does the temperature cut out activate ? 10.22.7 Output 9 Cooling of vessel Does the reactor tube cool down? /-/ G:\Eng\fermentorcontrollers\MFCS gebouw 4\39-Applikon-de IQ\Applicon 1030-1035 fermentor controller IQ.doc. Page 4 of 5 . 3/11/03 11:51 AM 11-assigning the analogue outputs: Main menu-Config F4-Setup F1-Manual F5-Delete analogue 1 F4 Delete Analogue 2 F4-Define F5-Analogue 1-Agitation F1-Edit F5-Max value 1200 rpm-Next F1-Low limit 0.00 rpm-Edit F5-High limit 1200. Arrow up-Select analogue Output 2 F1-Define F5-Flowrate F2 ml/min F1 -Next-Next-Edit F5-High limit 10.oo ml/min- Previous F2-Previous F2 -Max value=10 ml/min Details of the fermentor controllers involved: Type 8840326 AD11030 AD 11030 8840326 8840326 8840326 8840326 AD11030 Manufacturer B.Braun Applikon Applikon B.Braun B.Braun B.Braun B.Braun Applikon Serial no. 03276/00 P05260/34 P11328/77 04291/01 04310/01 4359 4393 P14571/20 Alias PM-3370 PK-2900 PK-0600 PM-3600 PM-3750 PM4300 PM4100 Karel Network ID 1 2 3 4 5 6 7 8 Version 4.40 Config BC70 4.43 4.43 4.43 4.43 BC73 BC73 BA82 BA82 02 mass flow 0-200ml/min 0-10ml/min 0-10ml/min 0-25ml/min 0-25ml/min 0-150mln/min 0-150mln/min 0-10ml/min Display % Mln/min Mln/min Ccm Ccm