Chapter 4 Software index b90 : External control operation mode 000: Forward/ Stop-Reverse/Stop 001: Run/ Stop-Forward/Reverse 002: 3-wire—Run/ Stop 1.) b90 is only available when A00 = 001 (control from terminals TM2). 2.) When both forward and reverse commands are ON, output is stopped. Parameter b90 = 000 (1). NPN input signal: (2). PNP input signal: S1 (Forward/Stop) S1 (Forward/Stop) S2 (Reverse/Stop) S2 (Reverse/Stop) COM (0V Common) 24V (24V Common) Parameter b90 = 001 (1). NPN input signal: (2). PNP input signal: S1 (Run/Stop) S1 (Run/Stop) S2 (Forward/Reverse) S2 (Forward/Reverse) COM (0V Common) 24V (24V Common) Parameter b90 = 002 (2). PNP input signal: (1). NPN input signal: S1 (Run) S2 (Stop) S1 (Run) S2 (Stop) S3 (Forward/Reverse) S3 (Forward/Reverse) COM (0V Common) 24V (24V Common) Note:- In 3 wire control mode terminals S1-S3 are used , therefore parameters b35 ~ b37 are ineffective. 4-34