Download MELSEC iQ-R CC-Link System Master/Local Module User`s Manual
Transcript
No. Name Availability (: Available, : Not available) Description Online SW007C to SW007F Temporary error invalid status Stores whether a station is in the temporary error invalid status. 0: Normal 1: Temporary error invalid status b15 b14 b13 b12 to b3 b2 b1 SW007C 16 15 14 13 to 4 3 2 1 SW007D 32 31 30 29 to 20 19 18 17 SW007E 48 47 46 45 to 36 35 34 33 SW007F 64 63 62 61 to 52 51 50 49 A Offline Master station Local station b0 1 to 64 in the table indicate station numbers. The bits turn on by the number of occupied stations. Error invalid stations, reserved stations, station with the end station number, and stations later than that are excepted. SW0080 to SW0083 Data link status of other stations Stores the data link status of each station. 0: Normal 1: Data link error b15 b14 b13 b12 to b3 b2 b1 SW0080 16 15 14 13 to 4 3 2 1 SW0081 32 31 30 29 to 20 19 18 17 SW0082 48 47 46 45 to 36 35 34 33 SW0083 64 63 62 61 to 52 51 50 49 b0 1 to 64 in the table indicate station numbers. The bits turn on by the number of occupied stations. It takes maximum of six seconds for this register to turn on after a slave station connected to the master station or local station becomes faulty. The time until this signal turns on differs depending on the system configuration and error status. Temporary error invalid stations, error invalid stations, reserved stations, station with the end station number, and stations later than that are excepted. SW0084 to SW0087 Watchdog timer error occurrence status of other stations Stores whether a watchdog timer error has occurred. 0: No watchdog timer error 1: Watchdog timer error b15 b14 b13 b12 to b3 b2 b1 SW0084 16 15 14 13 to 4 3 2 1 SW0085 32 31 30 29 to 20 19 18 17 SW0086 48 47 46 45 to 36 35 34 33 SW0087 64 63 62 61 to 52 51 50 49 b0 1 to 64 in the table indicate station numbers. Only the bit corresponding to the start station number turns on. Reserved stations, station with the end station number, and stations later than that are excepted. SW0088 to SW008B Fuse blown status of other stations Stores whether a fuse blown error has occurred. 0: Normal 1: Fuse blown b15 b14 b13 b12 to b3 b2 b1 b0 SW0088 16 15 14 13 to 4 3 2 1 SW0089 32 31 30 29 to 20 19 18 17 SW008A 48 47 46 45 to 36 35 34 33 SW008B 64 63 62 61 to 52 51 50 49 1 to 64 in the table indicate station numbers. The bits turn on by the number of occupied stations. Reserved stations, station with the end station number, and stations later than that are excepted. APPENDICES Appendix 5 List of Link Special Register (SW) 163