lpfc_mes0460: 0460: Bring Adapter offline
DESCRIPTION: The FC driver has received a request to bring the adapter offline. This may occur when
running HBAnyware.
SEVERITY: Warning
LOG: LOG_INIT verbose
ACTION: None required.
lpfc_mes0463: 0463: Adapter firmware error: hostStatus: x%x, Info1(0xA8): x%x, Info2 (0xAC):
x%x
DESCRIPTION: The firmware has interrupted the host with a firmware trap error.
SEVERITY: Error
LOG: LOG_INIT verbose
ACTION: Review HBAnyware diagnostic dump information.
FCP Log Messages (0701 - 0749)
lpfc_mes0701: 0701: Issue Abort Task Set to PathId: x%x, TargetId: x%x, Lun: x%x
DESCRIPTION: The driver has issued a task management command for the indicated SCSI device
address.
SEVERITY: Warning
LOG: LOG_INIT verbose
ACTION: Review system configuration.
lpfc_mes0703: 0703: Issue LUN reset to PathId: x%x, TargetId: x%x, Lun: x%x, Did: x%x
DESCRIPTION: Storport is requesting a reset of the indicated LUN.
SEVERITY: Warning
LOG: LOG_INIT verbose
ACTION: Review system configuration. Possible side-effect of cluster operations.
lpfc_mes0713: 0713: Issued Target Reset to PathId:%d, TargetId:%d, Did: x%x
DESCRIPTION: Storport detected that it needs to abort all I/O to a specific target. This results in login
reset to the target in question.
SEVERITY: Warning
LOG: LOG_FCP verbose
ACTION: Review system configuration. Possible side-effect of cluster operations.
SEE ALSO: lpfc_mes0714.
lpfc_mes0714: 0714: Issued Bus Reset for PathId:%d
DESCRIPTION: Storport is requesting the driver to reset all targets on this adapter.
SEVERITY: Warning
LOG: LOG_FCP verbose
ACTION: Review system configuration. Possible side-effect of cluster operations.
SEE ALSO: lpfc_mes0713.
lpfc_mes0716: 0716: FCP Read Underrun, expected%d, residual%d
DESCRIPTION: FCP device provided less data than was requested.
SEVERITY: Supplement Information
LOG: LOG_FCP verbose
ACTION: No action needed, informational.