Download Emulex Drivers for Windows
Transcript
Single TCP Connection Performance Settings One common benchmark is to run a single TCP connection between two computers as fast as possible. The following are a few suggestions to deliver the best possible performance: • Use TCP window scaling with a 256 Kb or 512 Kb window. This may be controlled with show socket applications, such as ntttcp from Microsoft. • Use send and receive buffers that are larger than 128 Kb with an efficient application such as ntttcp. • Disable RSS and use an interrupt filter driver. Experiment with all relative CPU affinities to find the best combination. • Disable timestamps and SACK, because the test should run without dropping any packets. • Unbind unused network protocols in the Network Connections property page. • Disable any firewall services, IPSEC, or NAT. iSCSI Error Handling The goal of iSCSI error handling is to be tolerant of link level and target level failures up to configured timeout values, so that I/O errors are not seen by the application or operating system. The error handling is triggered under the following conditions: • Loss of immediate link to the UCNA (such as a cable disconnect or port failure). The UCNA firmware detects the loss of link and notifies the driver. When this happens, the driver queues the I/O requests internally, up to a configured timeout period, so that the operating system does not see I/O errors. This timeout is known as link-down timeout (LDTO). • Loss of connection to the target because of target or network disconnection at the target. If the driver has I/O requests pending with the target and the target becomes unavailable (because the target is down, has failed over, or network issues are detected at the target), the driver queues the I/O request internally up to a configured timeout period. This timeout is known as extended timeout (ETO). If the configured threshold for LDTO and ETO is reached and the UCNA is still unable to connect to the target, the driver fails all I/O requests. I/O errors are seen by the application and operating system. Note: Following a link up, switch ports can take a long time to initialize and go to a forwarding state. Because of this, add additional time to the ETO and LDTO settings to eliminate I/O disruption or target unavailability. If the switch port is connected to a single host, then PortFast mode can be enabled on the switch port to eliminate delays in transitioning to a forwarding state. Configuring LDTO and ETO on Windows Server LDTO and ETO values are configured via the Windows registry. Table 10 lists the default values of LDTO and ETO on Windows Server and the limits within which they can be configured. Note: If the ETO is set to a number between 0 and 19, the driver assumes the value to 20 seconds internally. You will not see any modification to the registry. Table 10: LDTO and ETO Information on Windows Server Value Default Minimum Maximum LDTO 20 sec 0 sec 3600 sec ETO 90 sec 0 sec 3600 sec Emulex Drivers for Windows User Manual Page 46