Controller Installation
7.3 Controller Elements
7.4 Technical Data of the Controller
ƒƒ Power on/off switch – The power switch is used to
start or stop the system and as a reset switch. It does not
work as power disconnect switch.
Refer to “Table 2: Technical data of the PS controller” on
page 19 for an overview of the most important technical
specifications of the PS controller.
ƒƒ Indicator Lights – The five LED lights on the front
indicate different operational situations. For a detailed
explanation refer to chapter “10 Operating the Pump”
on page 60.
Table 2: Technical data of the PS controller
Model
Pump motor:
rated power
Affiliated pump
motor
[kW]
Max. DC input
voltage
Min. recommended
Vmp
Max.output
current
[V]
[V]
[A]
PS150
Boost
0.3
ECDRIVE 150-Boost
50
17
18
PS150
0.3
ECDRIVE 150-C
50
17
18
PS200
0.3
ECDRIVE 200-HR
100
34
11
PS600
0.7
150
68
13
200
102
9.5
200
102
14
375
238
15
ECDRIVE 600-HR
ECDRIVE 600-C
ECDRIVE 600-CS-F
PS1200
1.7
PS1800
1.7
ECDRIVE 1200-HR
ECDRIVE 1200-C
ECDRIVE 1200-HR
ECDRIVE 1200-C
ECDRIVE 1800-CS-F
ECDRIVE 4000-HR
PS4000
3.5
ECDRIVE 4000-C
ECDRIVE 4000-CS-F
19