Pump Installation 8.5 Boost Surface Pumps 8.5.1 Placement and Foundation WARNING – PS Boost pumps must not be submerged in or exposed to other sources of water, e.g. rain. Operating noises – Make sure, by applying appropriate measures, that the environment will not be impaired by any sound produced by the pump. Space – During installation, make sure that there is enough space available to permit subsequent disassembly of the motor unit. WARNING – The pump might heat up in operation. It must be installed on a non flammable surface. Connecting the pump to the foundation – Fastening the pump to the foundation should be done exclusively by using bolts, threads or dowels in order to avoid blocking the removal of the motor unit. CAUTION – Inlet- and outlet-pipes must be attached to the pump free of tension. Figure 21: LORENTZ boost pump 8.5.2 Pump Motor Wiring L1 – L2 – L3 – ECDRIVE requires four-conductor (four-wire) cable between the controller and the motor. The three wires L1, L2 and L3 carry power. The fourth wire carries ground. To reverse direction of rotation reverse any two phases. CAUTION – No disconnect switches must be installed between motor and pump controller. Connecting the motor wire to the switched-on controller can cause damage. Such damage is excluded from the warranty. 49