Download M300 Reference Guide - Science Engineering Associates, Inc.
Transcript
Type 71 (Pressure Multiplexer) SEA Model 300 Type 71 (Pressure Multiplexer) Description This acquisition type is used to acquire two bytes of data from the SEA Pressure Multiplexer box. Parameters Parameter Usage Limits 1 Box ID 0-255 2 Channel 0-255 3 Gain 0-3 Parameters Data Size This routine acquires two 8 bit bytes. Two bytes of data should be allocated for each sample. Data Format The data acquired is in two's complement integer coding and represents the signed digital value of the analog signal. 0x7FFF 327678 +full scale 0x0000 0 zero 0x8000 -32768 -full scale Data Format Type Synchronous event. Acquisition Reference 142