Download 2 - Conair

Transcript
CUTTER OPERATION
PROBLEMS, CONT’D
Symptom
Possible cause
Solution
◆ In encoder or
There is a problem with the
cutter control.
Check for control output.
There is a problem with the
servo amplifier.
See Checking the Servo
Amplifier.
There is a loose connection.
Check wiring for loose connections.
There is an anti-jam circuit
signal.
This error appears when the
blade does not go through the
cut cycle in the required time.
timer modes, the
display shows the
count which resets,
but a cut does not
occur at the point
of reset.
◆ Cutter control
displays “Blade
error”.
Check for:
❒ Loose connection on cutter
control or servo amplifier.
❒ Fault on Amplifier preventing cut cycle.
❒ Blade is stuck in extrudate/
bushings.
◆ Cutter control
displays “Blade
error”.
UGE048/0399
There is a problem with the
home proximity switch.
See Adjusting the Proximity
Switches, page 6-17.
There is a problem in the
guard circuit.
Make sure the E-stop and
Reset buttons are in the correct
operating positions. Check
guard circuit for loose connections or bad switches. Replace
if necessary.
SCE/SCX Combination Puller/Cutter
TROUBLESHOOTING
6-9