Download User Manual

Transcript
2-12
INSTALLATION
ORBAN MODEL 9300

Four Soft buttons provide access to all 9300 functions and controls. The functions of the soft buttons change with each screen, following the labels at the
bottom of each screen.

Next and Prev ( and ) buttons scroll the screen horizontally to accommodate menus that cannot fit in the available space. They also allow you to move
from one character to the next when you enter data into your 9300. These flash
when such a menu is in use. Otherwise, they are inactive.

Control Knob is used to change the setting that is selected by the soft buttons.
To change a value, you ordinarily have to hold down a soft button while you are
turning the control knob.

Recall button allows you recall a Factory or User Preset.
Selecting the Recall button does not immediately recall a preset. See step
16 on page 2-18 for instructions on recalling a preset.

Modify button brings you to list of controls that you can use to edit a Factory or
User Preset. If you edit a Factory Preset, you must save it as a new User Preset to
retain your edit.

Setup button accesses the technical parameters necessary to match the 9300 to
your transmission system.

Escape button provides an escape from the currently active screen, returning
the user to the next higher-level screen. Repeatedly pressing Escape will always
return you to the Idle screen, which is at the top level of the screen hierarchy.

Input meters show the peak input level applied to the 9300’s analog or digital
inputs with reference to 0 = digital full-scale. If the input meter’s red segment
lights up, you are overdriving the 9300’s analog to digital converter. This clips at
+27 dBu.

AGC meter shows the gain reduction of the slow two-band AGC processing that
precedes the separate analog and digital processing chains. Full-scale is 25 dB
gain reduction. You can switch the meter so that it either reads the gain reduction of the Master (above-200 Hz) band, the Bass (below-200 Hz) band, or the
difference between the gain reduction in the Master and Bass bands.
The latter reading is useful for assessing the dynamic bass equalization
that the AGC produces and it helps you set the AGC BASS COUPLING control.

Gate LED indicates gate activity, lighting when the input audio falls below the
threshold set by the AGC gate threshold control (via the Full Control screen’s
AGC GATE control). When this happens, the AGC’s recovery time is slowed to
prevent noise rush-up during low-level passages.