Download HP StorageWorks Command View SDM Installation & User Guide
Transcript
logprn -a myarray -s 111908302000 -e 010115302001 -t Device -v This command will produce the following output (only one entry shown): = = = = = = = = = = = = 50060B000008A085 October 13, 2000 8:27:34 AM EDT HP VA7100 VirtualArray 90339 M/C1 374 1 2447 Controller Event of the error provided here. Standard Output Display all log entries to standard out for the local host. logprn This command produces the following output (only one entry shown): October 13, 2000 8:27:34 AM EDT HP VA7100 VirtualArray 50060B000008A085 The text description of the error will be provided here. BUS: Local Brief output Display all log entries in brief output for array Array1 on remote host server6. logprn -a server6:Array1 -b This command will produce the following output (only one entry shown): 50060B000008A085_ October 13, 2000_8:27:34 AM EDT_HP VA7100_VirtualArray_90339_M/C1_374_1_2447_1_The text description of the error will be provided here... Limit Log Type Get only Abnormal Termination events for an array with an alias of DevArray connected to the local host. Find the logs in the directory /temp/logs. logprn –a DevArray –t AbtermEvent –d /temp/logs Array Logs 227 Array Logs DeviceUniqueName Date Time DeviceName DeviceType DeviceSequence FruIdentifier FRULocation LogCode Count Sequence Type Text : The text description