Download TOC-VCPH/CPN & TOC-Control V Software
Transcript
4.1 Analysis Preparation 4.1.14 Preparation and Storage of Standard Solutions 4.1.14 Preparation and Storage of Standard Solutions 4.1.14.1 Preparation of Standard Solutions Zero water refers to a standard solution with zero concentration of TC, IC or TN; zero water also refers to the water used to prepare these standard solutions. Water that is, in theory, absolutely free of carbon (TC) or nitrogen (TN) is used as zero water. In practice, it is difficult to obtain this type of water. Even ultra-pure water obtained using a highperformance membrane technique and water that has been repeatedly distilled will have a TC content of about 10µg/L. This value is measured directly after manufacture, and increases when the water is stored in a container. Carbon dioxide is contained in the atmosphere at concentrations ranging from 300 to 500mg/L. The CO2 content of ambient air is higher in a room with many people or where combustion equipment is used. Carbon dioxide in ambient air dissolves in stored water, taking the form of IC. The dissolved amount is generally about 0.2mg/L, but depends on the water temperature and carbon dioxide content of the air in contact with the water. Refer to Table 6.2 • "CO2 Content (ppm) in Distilled Water Equilibrated with Atmosphere Temperature (°C)". Instruments that prevent contact with air are not incorporated in water uptake, retention or storage processes during common distillation and purification of water. For this reason, IC is present in most types of distilled and purified water. In some cases, the TC content of commercially-available distilled water stored in plastic or glass containers is 1ppm. Note: The degree of purity required varies depending on the analysis range. Use of commercially-available purified water is acceptable when measuring samples with expected TC concentrations around 100ppm. The quality of the zero water should be considered along with the analysis range. Preparation of TC Standard Solutions 60 1. Accurately weigh 2.125g of reagent grade potassium hydrogen phthalate that was previously dried at 105-120°C for about 1 hour and cooled in a desiccator. 2. 3. Transfer to a 1 L volumetric flask and dissolve in zero water. 4. The standard stock solution is diluted with zero water to prepare standard solutions at the required concentrations. Note: The TC standard solution reagent need not be potassium hydrogen phthalate. Depending on the application, other substances are also acceptable (e.g., sucrose, etc.). TOC-VCPH/CPN Add zero water to the 1 L mark, and stir the solution. The carbon concentration of the solution is 1000mgC/L (1000mgC/L = 1000ppmC). This solution is the standard stock solution. Note: The standard stock solution may be prepared at other concentrations. For example, a 2000mgC/L solution can be used as the standard stock solution.