Download Classic Lambda 25-60 User Manual

Transcript
Trouble-shooting description
Report no. Origin
Disconnect the polarity proof connector plug befor solving Trouble shooting
Reason/Problem
Solution (when done solving the problem push the Enter button)
0103
0104
0105
0106
0107
0108
0109
0110
0111
0112
0113
0114
0120
HWS tank sensor 3 short circuited
HWS tank sensor 3 interrupted
HWS tank sensor 4 short circuited
HWS tank sensor 4 interrupted
Flow sensor 3 short circuited
Flow sensor 3 interrupted
Flow sensor 4 short circuited
Flow sensor 4 interrupted
Remote control HC3 short circuited
Remote control HC3 interrupted
Remote control HC4 short circuited
Remote control HC4 interrupted
Data transmission EM 2
Sensor or connection short circuited.
Sensor not connected or connection interrupted.
Sensor or connection short circuited.
Sensor not connected or connection interrupted.
Sensor or connection short circuited.
Sensor not connected or connection interrupted.
Sensor or connection short circuited.
Sensor not connected or connection interrupted.
Remote control or connection short circuited.
Remote control not connected or connection interrupted.
Remote control or connection short circuited.
Remote control not connected or connection interrupted.
No connection with extension module 2.
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
Set the extension module's adress switch to "2"; check HC's connection and bus wiring as well as fuse F23 (see board scheme); replace extension module
2;
0121
0122
0123
0124
0125
0126
0127
0128
0129
0130
0131
0132
ADC-error in EM 2
Zero-point error ext. module 2
HWS tank sensor 5 short circuited
HWS tank sensor 5 interrupted
HWS tank sensor 6 short circuited
HWS tank sensor 6 interrupted
Flow sensor 5 short circuited
Flow sensor 5 interrupted
Flow sensor 6 short circuited
Flow sensor 6 interrupted
Remote control HC5 short circuited
Remote control HC5 interrupted
Extension module 2 thermometry defect
Control of outlets in extension module 1 defect
Sensor or connection short circuited.
Sensor not connected or connection interrupted.
Sensor or connection short circuited.
Sensor not connected or connection interrupted.
Sensor or connection short circuited.
Sensor not connected or connection interrupted.
Sensor or connection short circuited.
Sensor not connected or connection interrupted.
Remote control or connection short circuited.
Remote control not connected or connection interrupted.
Replace extension module 2;
Replace extension module 2;
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
see no.0020 - 0031
0133
0134
0200
0201
Remote control HC6 short circuited
Remote control HC6 interrupted
Wrong software version
Boiler module not assigned or CAN
interrupted
Remote control or connection short circuited.
Remote control not connected or connection interrupted.
Software verswions of the boiler control unit and digital remote control don't
No connection with the boiler.
see no.0020 - 0031
see no.0020 - 0031
Update the boiler control's and remote control's sofware accordingly; (matching EPROM softwares)
Boiler control unit not assigned; check power supply and BUS wiring or replace the remote control;
0202
Interfering BUS-configuration of two control Two or more remote controls assigned to the same heating circuit.
modules
Correct parameter Z2 of the digital remote control;
0211
Digital remote control 1 not connected
No connection with HC1's digital remote control
Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote;
0212
Digital remote control 2 not connected
No connection with HC2's digital remote control
Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote;
0213
Digital remote control 3 not connected
No connection with HC3's digital remote control
Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote;
0214
Digital remote control 4 not connected
No connection with HC4's digital remote control
Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote;
0215
Digital remote control 5 not connected
No connection with HC5's digital remote control
Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote;
0216
Digital remote control 6 not connected
No connection with HC6's digital remote control
Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote;
After correction of defects, Press ENTER !