Trouble-shooting description Report no. Origin Disconnect the polarity proof connector plug befor solving Trouble shooting Reason/Problem Solution (when done solving the problem push the Enter button) 0103 0104 0105 0106 0107 0108 0109 0110 0111 0112 0113 0114 0120 HWS tank sensor 3 short circuited HWS tank sensor 3 interrupted HWS tank sensor 4 short circuited HWS tank sensor 4 interrupted Flow sensor 3 short circuited Flow sensor 3 interrupted Flow sensor 4 short circuited Flow sensor 4 interrupted Remote control HC3 short circuited Remote control HC3 interrupted Remote control HC4 short circuited Remote control HC4 interrupted Data transmission EM 2 Sensor or connection short circuited. Sensor not connected or connection interrupted. Sensor or connection short circuited. Sensor not connected or connection interrupted. Sensor or connection short circuited. Sensor not connected or connection interrupted. Sensor or connection short circuited. Sensor not connected or connection interrupted. Remote control or connection short circuited. Remote control not connected or connection interrupted. Remote control or connection short circuited. Remote control not connected or connection interrupted. No connection with extension module 2. see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 Set the extension module's adress switch to "2"; check HC's connection and bus wiring as well as fuse F23 (see board scheme); replace extension module 2; 0121 0122 0123 0124 0125 0126 0127 0128 0129 0130 0131 0132 ADC-error in EM 2 Zero-point error ext. module 2 HWS tank sensor 5 short circuited HWS tank sensor 5 interrupted HWS tank sensor 6 short circuited HWS tank sensor 6 interrupted Flow sensor 5 short circuited Flow sensor 5 interrupted Flow sensor 6 short circuited Flow sensor 6 interrupted Remote control HC5 short circuited Remote control HC5 interrupted Extension module 2 thermometry defect Control of outlets in extension module 1 defect Sensor or connection short circuited. Sensor not connected or connection interrupted. Sensor or connection short circuited. Sensor not connected or connection interrupted. Sensor or connection short circuited. Sensor not connected or connection interrupted. Sensor or connection short circuited. Sensor not connected or connection interrupted. Remote control or connection short circuited. Remote control not connected or connection interrupted. Replace extension module 2; Replace extension module 2; see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 see no.0020 - 0031 0133 0134 0200 0201 Remote control HC6 short circuited Remote control HC6 interrupted Wrong software version Boiler module not assigned or CAN interrupted Remote control or connection short circuited. Remote control not connected or connection interrupted. Software verswions of the boiler control unit and digital remote control don't No connection with the boiler. see no.0020 - 0031 see no.0020 - 0031 Update the boiler control's and remote control's sofware accordingly; (matching EPROM softwares) Boiler control unit not assigned; check power supply and BUS wiring or replace the remote control; 0202 Interfering BUS-configuration of two control Two or more remote controls assigned to the same heating circuit. modules Correct parameter Z2 of the digital remote control; 0211 Digital remote control 1 not connected No connection with HC1's digital remote control Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote; 0212 Digital remote control 2 not connected No connection with HC2's digital remote control Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote; 0213 Digital remote control 3 not connected No connection with HC3's digital remote control Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote; 0214 Digital remote control 4 not connected No connection with HC4's digital remote control Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote; 0215 Digital remote control 5 not connected No connection with HC5's digital remote control Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote; 0216 Digital remote control 6 not connected No connection with HC6's digital remote control Check parameter Z2 and the BUS wiring; check fuse F23 (see board scheme); replace the digital remote; After correction of defects, Press ENTER !